74 research outputs found
Ultrasonic characterization of subsurface 2D corrugation
The ultrasonic backscattering technique is employed for the characterization of a 2D surface corrugation which is superposed on or hidden on the backside of a polycarbonate sample. In contrast to previous studies where the incident angle at well-defined and a-priori known symmetry orientations of the surface structure is varied in order to extract the characteristic periodicities, the backscatter polar scan method incorporates an additional variation of the orientation of the vertical insonification plane within the experimental measurement protocol. As such, the characteristic periodicities as well as the surface symmetries can be extracted without any prior knowledge of the surface structure. As a benefit compared to optical methods, we have also validated this extended methodology for the investigation of a 2D subsurface corrugation. Although the diffraction conditions do not change in comparison with a visible 2D surface corrugation, we remark that additional attention is required in the sense that the elastic properties of the substrate material put further restrictions to the range of applicable ultrasonic frequencies. The characterized periodicities and symmetries are in excellent agreement with the design parameters of the (hidden) 2D surface grating
A novel ultrasonic strain gauge for single-sided measurement of a local 3D strain field
A novel method is introduced for the measurement of a 3D strain field by exploiting the interaction between ultrasound waves and geometrical characteristics of the insonified specimen. First, the response of obliquely incident harmonic waves to a deterministic surface roughness is utilized. Analysis of backscattered amplitudes in Bragg diffraction geometry then yields a measure for the in-plane strain field by mapping any shift in angular dependency. Secondly, the analysis of the reflection characteristics of normal incident pulsed waves in frequency domain provides a measure of the out-of-plane normal strain field component, simply by tracking any change in the stimulation condition for a thickness resonance. As such, the developed ultrasonic strain gauge yields an absolute, contactless and single-sided mapping of a local 3D strain field, in which both sample preparation and alignment procedure are needless. Results are presented for cold-rolled DC06 steel samples onto which skin passing of the work rolls is applied. The samples have been mechanically loaded, introducing plastic strain levels ranging from 2% up to 35%. The ultrasonically measured strains have been validated with various other strain measurement techniques, including manual micrometer, longitudinal and transverse mechanical extensometer and optical mono- and stereovision digital image correlation. Good agreement has been obtained between the ultrasonically determined strain values and the results of the conventional methods. As the ultrasonic strain gauge provides all three normal strain field components, it has been employed for the extraction of Lankford ratios at different applied longitudinal plastic strain levels, revealing a strain dependent plastic anisotropy of the investigated DC06 steel sheet
An ultrasonic strain gauge
International audienceA method is introduced for the measurements of strain exploiting the interaction between ultrasound waves and characteristics of the insonified specimen. First, the response of obliquely incident harmonic waves to a deterministic surface roughness is utilized. Analysis of backscattered amplitudes in Bragg diffraction geometry then yields a measure for the in-plane strain field by mapping any shift in angular dependency. Secondly, the analysis of the reflection characteristics of normal incidence pulsed waves in frequency domain provides the out-of-plane normal strain field component, simply by tracking any change in the stimulation condition for a thickness resonance. As such, the developed method yields an absolute, contactless and single-sided mapping of a local 3D strain field, in which both sample preparation and alignment procedure are ubiquitous. The ultrasonic strain gauge is applicable to any material, though under the restriction that a deterministic surface roughness is present. Results are presented for cold-rolled DC06 steel samples onto which skin passing of the work rolls is applied. The samples have been mechanically loaded, introducing plastic strain levels ranging from 2% to 35%. The ultrasonically measured strains have been validated with other strain measurement techniques, yielding good agreement. As the ultrasonic strain gauge provides all three strain field components, we extracted Lankford ratios for the DC06 steel sheet at different applied plastic strain levels revealing a strain dependent plastic anisotropy of the DC06 steel
Damage signature of fatigued fabric reinforced plastics in the pulsed ultrasonic polar scan
This study investigates the use of both the amplitude and time-of-flight based pulsed ultrasonic polar scan (P-UPS) for the nondestructive detection and evaluation of fatigue damage in fiber reinforced composites. Several thermoplastic carbon fabric reinforced PPS specimens (CETEX), loaded under various fatigue conditions, have been scanned at multiple material spots according to the P-UPS technique in order to extract material degradation in a quantitative way.
The P-UPS results indicate that shear dominated fatigued carbon/PPS goes with a reduction of shear properties combined with large fiber distortions. The P-UPS results of the tension-tension fatigued carbon/PPS samples on the other hand reveal a directional degradation of the stiffness properties, reaching a maximum reduction of -12.8% along the loading direction. The P-UPS extracted damage characteristics are fully supported by simulations, conventional destructive tests as well as visual inspection. The results demonstrate the excellent capability of the P-UPS method for nondestructively assessing and quantifying both shear-dominated and tension-tension fatigue damage in fabric reinforced plastics
Presence and analysis of plasmids in human and animal associated Arcobacter species
In this study, we report the screening of four Arcobacter species for the presence of small and large plasmids. Plasmids were present in 9.9% of the 273 examined strains. One Arcobacter cryaerophilus and four Arcobacter butzleri plasmids were selected for further sequencing. The size of three small plasmids isolated from A. butzleri and the one from A. cryaerophilus strains ranged between 4.8 and 5.1 kb, and the size of the large plasmid, isolated from A. butzleri, was 27.4 kbp. The G+C content of all plasmids ranged between 25.4% and 26.2%. A total of 95% of the large plasmid sequence represents coding information, which contrasts to the 20 to 30% for the small plasmids. Some of the open reading frames showed a high homology to putative conserved domains found in other related organisms, such as replication, mobilization and genes involved in type IV secretion system. The large plasmid carried 35 coding sequences, including seven genes in a contiguous region of 11.6 kbp that encodes an orthologous type IV secretion system found in the Wolinella succinogenes genome, Helicobacter pylori and Campylobacter jejuni plasmids, which makes this plasmid interesting for further exploration
Identification of the elastic properties of isotropic and orthotropic thin-plate materials with the pulsed ultrasonic polar scan
Already in the early 1980's, it has been conjectured that the pulsed ultrasonic polar scan (P-UPS) provides a unique fingerprint of the underlying mechanical elasticity tensor at the insonified material spot. Until now, that premise has not been thoroughly investigated, nor validated, despite the opportunities this would create for NDT and materials science in general. In this paper, we report on the first-ever implementation of an inverse modeling technique on the basis of a genetic optimization scheme in order to extract quantitative information from a P-UPS. We validate the optimization approach for synthetic data, and apply it to experimentally obtained polar scans for annealed aluminum, cold rolled DC-06 steel as well as for carbon fiber reinforced plastics. The investigated samples are plate-like and do not require specific preparation. The inverted material characteristics show good agreement with literature, micro-mechanical models as well as with results obtained through conventional testing procedures
- …