103 research outputs found

    Particle Acceleration and Cosmic-Ray Origin in the Galaxy

    Get PDF
    In 1990's Very High Energy Gamma-ray Astrophysics has dramatically advanced due to the Imaging Air \v{C}erenkov Telescopes(IACTs). After the first detection of TeV gamma-ray emission from the Crab nebula in 1989, several type of TeV gamma-ray sources, Active Galactic Nuclei(AGN), young pulsar, and SuperNova Remnant(SNR), have been detected. In those discoveries, recent detections of both synchrotron X-rays and TeV gamma-ray emissions from several SNRs are very significant. SNR has been widely believed to be an unique candidate of galactic cosmic-ray origin since the beginning of cosmic-ray physics, whereas little observational evidences have been reported so far. Those are expected to be a clue of not only the galactic cosmic-ray origin but also the understanding of the particle acceleration due to a diffusive shock. Here I present the recent results obtained by our group, CANGAROO, about the evidences of electron and proton acceleration in SNRs.Comment: 9 pages, 9 figures, to appear in proceedings of the conference " The International Symposium on Science of Super-Strong Field Interactions" held in Japan Hayama, March 200

    Imaging Gaseous Detector based on Micro Processing Technology

    Get PDF
    The development of gaseous detectors has been exciting again since the appearance of a MicroStrip Gas Chamber(MSGC) in 1988, which is made using a micro-electronics technology. These days lots of variations of the advanced gaseous detectors are being intensively studied in the world. We have developed the two-dimensional MSGC having a 10 cm square detection area and the ultra fast readout system for a real time X-ray imaging. The MSGC was made using Multi-Chip Module (MCM) technology, and has a very thin substrate of 17 μ\mum, lots of thin anodes and back strips both with 200 μ\mum pitches. This enables us to get fast digital X-ray images with recording both the timing and an energy of each X-ray photon. In addition, an intermediate gas multiplier has been realized using a capillary plate having a conductive surface of a capillary. The MSGC combined with the conductive capillary plate can be steadily operated with a high gain under intense irradiation. Here we also report new approaches of X-ray crystal structure analyses using timing information obtained by the MSGC.Comment: 14 papges, 10 figures, to appear in the proceedings of Solid State Detectors for 21st Century (Nucl. Instru. and Meth. A

    Performance of large area Micro Pixel Chamber

    Full text link
    A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536 pixel anodes of 400um pitch on a 100um thick insulating substrate. Achieved energy resolution was 30% (FWHM) at 5.9keV, and a gas gain of 7000 was obtained with argon ethane (8:2) gas mixture. This gain is high enough to detect minimum ionizing particles with such a small electrode pitch. Although several discharges occurred during 65 hours continuous operation, the detectors have kept stable operation with high gain. The micro-PIC is a useful detector for many applications e.g. X-ray, gamma ray, and charged particle imaging. The micro electrode structure allows us to measure directions of primary electrons due to incident X-rays or gamma rays, which provide a strong method for X-ray polarimetry and gamma-ray imaging.Comment: 4 pages, 8 figures, to appear in the proceedings of 6th International Conference on Position Sensitive Detectors, 9-13 Sep 2002, Leicester, UK (Nucl. Instr. and Meth. A

    Performance of the TPC with Micro Pixel Chamber Readout: micro-TPC

    Get PDF
    Micro-TPC, a time projection chamber(TPC) with micro pixel chamber(μ\mu-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position sensitive gaseous detector, or the μ\mu-PIC, with the detection area of 10×\times10 cm2{}^{2} and 65536 anode electrodes of 400 μ\mum pitch. We achieved the gas gain of over 10000 without any other multipliers. With the pipe-line readout system specially developed for the μ\mu-PIC, we detected X-rays at the rate as high as 7.7 Mcps. We attached a drift cage with an 8 cm drift length to the μ\mu-PIC and developed a micro-TPC. We measured the basic performances of the micro-TPC and took three-dimensional tracks of electrons. We also developed a prototype of the MeV gamma-ray imaging detector which is a hybrid of the micro-TPC and NaI(Tl) scintillators and confirmed its concept by reconstructing the obtained data.Comment: 6 pages 16 figures, submitted for IEEE/TNS 200

    Observation of MeV-Gamma-Rays from relativistic electron precipitation with Balloon Borne Experiment around the Northern Polar Cap

    Get PDF
    第2回極域科学シンポジウム/第35回極域宙空圏シンポジウム 11月15日(火) 国立極地研究所 2階大会議

    Performance of a Time-Projection-Chamber with a Large-Area Micro-Pixel-Chamber Readout

    Full text link
    A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a two-dimensional imaging device and a gas electron multiplier with an effective area of 23*28 cm^2 as a pre-gas-multiplier. The micro-TPC was operated at a gas gain of 50,000, and energy resolutions and spatial resolutions were measured.Comment: 4 pages, 7 figures, proceedings of IWORID

    Development of a time projection chamber with micro pixel electrodes

    Full text link
    A time projection chamber (TPC) based on a gaseous chamber with micro pixel electrodes (micro-PIC) has been developed for measuring three-dimensional tracks of charged particles. The micro-PIC with a detection area of 10 cm square consists of a double-sided printing circuit board. Anode pixels are formed with 0.4 mm pitch on strips aligned perpendicular to the cathode strips in order to obtain a two-dimensional position. In the TPC with drift length of 8 cm, 4 mm wide field cage electrodes are aligned at 1mm spaces and a uniform electric field of about 0.4 kV/cm is produced. For encoding of the three-dimensional position a synchronous readout system has been developed using Field Programmable Gate Arrays with 40 MHz clock. This system enables us to reconstruct the three-dimensional track of the particle at successive points like a cloud chamber even at high event rate. The drift velocity of electrons in the TPC was measured with the tracks of cosmic muons for three days, during which the TPC worked stably with the gas gain of 3000. With a radioisotope of gamma-ray source the three-dimensional track of a Compton scattered electron was taken successfully.Comment: 4 pages, 7 figures, to appear in the proceedings of 6th International Conference on Position Sensitive Detectors, 9-13 Sep 2002, Leicester, UK (Nucl. Instr. and Meth. A

    Study of Negative-Ion TPC Using {\mu}-PIC for Directional Dark Matter Search

    Full text link
    Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the {\mu}-PIC+GEM system and obtained sufficient gas gain with CS2_{2}gas and SF6_{6} gas at low pressures. We expect an improvement in detector sensitivity and angular resolution with better electronics
    corecore