40 research outputs found
Przygotowanie powierzchni próbek ze stali X38CrMoV5-1pod powłoki ochronne metodą szlifowania elektroerozyjnego AEDG i polerowania.
W artykule przedstawiono technologię przygotowania powierzchni próbek ze stali narzędziowej X38CrMoV5-1 z zastosowaniem szlifowania elektroerozyjnego AEDG i polerowania mechanicznego. Zakres badań obejmuje porównanie struktury geometrycznej powierzchni SGP ukształtowanej w procesach szlifowania AEDG,
polerowania oraz po wytworzeniu warstw ochronnych PVD typu: TiC+a-C:H oraz MoS2TiW. Do pomiarów
geometrii powierzchni w poszczególnych etapach zastosowano mikroskop konfokalny (CLSM) oraz profilometr
mechaniczny i optyczny.In the paper the technology of surface layer preparation of samples made of X38CrMoV5-1 tool steel
with using abrasive electrodischarge grinding (AEDG) and mechanical polishing. The range of investigations
include comparison of surface texture formed in processes of AEDG grinding, polishing and after manufacturing of
PVD protective coatings type TiC+a-C:H and MoS2TiW. For measurements of surface geometry after separate
stages the confocal laser scanning microscopy (CLSM), mechanical and optical profiler have been used
Birth status and twin birth weight discordance
Abstract Objectives: The aim of the research was to estimate the influence of birth weight discordance on birth status of twins. Material and methods: Material of the research consisted of 560 foetuses derived from successful twin pregnancies. In the analysis the following factors were taken into consideration: birth status, gasometry, and birth weight discordance. Results: The degree of birth weight discordance under 10% was noted in 50% of twin pregnancies (n=140), discordance of 10%-20% was observed in 30.7% (n=86), and >20 % - in 19,3% (n=54). Conclusions: Birth weight discordance is an important risk factor for fetal and neonatal morbidity which is higher in smaller twins than in larger ones. Along with the degree of birth weight discordance, an increased risk of neonatal complications was observed
Hartree-Fock-Bogoliubov Theory of Polarized Fermi Systems
Condensed Fermi systems with an odd number of particles can be described by
means of polarizing external fields having a time-odd character. We illustrate
how this works for Fermi gases and atomic nuclei treated by density functional
theory or Hartree-Fock-Bogoliubov (HFB) theory. We discuss the method based on
introducing two chemical potentials for different superfluid components,
whereby one may change the particle-number parity of the underlying
quasiparticle vacuum. Formally, this method is a variant of non-collective
cranking, and the procedure is equivalent to the so-called blocking. We present
and exemplify relations between the two-chemical-potential method and the
cranking approximation for Fermi gases and nuclei.Comment: 11 RevTeX pages, 4 figures, submitted to Physical Review A, extended
versio
Recommended from our members
Microstructures Manufactured in Diamond by Use of Laser Micromachining.
Different microstructures were created on the surface of a polycrystalline diamond plate (obtained by microwave plasma-enhanced chemical vapor deposition-MW PECVD process) by use of a nanosecond pulsed DPSS (diode pumped solid state) laser with a 355 nm wavelength and a galvanometer scanning system. Different average powers (5 to 11 W), scanning speeds (50 to 400 mm/s) and scan line spacings ("hatch spacing") (5 to 20 µm) were applied. The microstructures were then examined using scanning electron microscopy, confocal microscopy and Raman spectroscopy techniques. Microstructures exhibiting excellent geometry were obtained. The precise geometries of the microstructures, exhibiting good perpendicularity, deep channels and smooth surfaces show that the laser microprocessing can be applied in manufacturing diamond microfluidic devices. Raman spectra show small differences depending on the process parameters used. In some cases, the diamond band (at 1332 cm-1) after laser modification of material is only slightly wider and shifted, but with no additional peaks, indicating that the diamond is almost not changed after laser interaction. Some parameters did show that the modification of material had occurred and additional peaks in Raman spectra (typical for low-quality chemical vapor deposition CVD diamond) appeared, indicating the growing disorder of material or manufacturing of the new carbon phase
Transcatheter aortic valve implantation in patients with bicuspid aortic valve: a series of cases
Wstęp: Obecność dwupłatkowej zastawki aortalnej (BAV) uważa się za względne przeciwwskazanie do zabiegu przezcewnikowej implantacji zastawki aortalnej (TAVI), a leczenie chirurgiczne pozostaje metodą z wyboru w przypadku jej ciasnego zwężenia. Procedura TAVI nie jest zalecana w tej grupie chorych m.in. ze względu na owalny kształt pierścienia zastawki dwupłatkowej w porównaniu z pierścieniem prawidłowej (trójpłatkowej) zastawki, co zwiększa ryzyko dysfunkcji i zniekształcenia protezy. Dwupłatkowa zastawka aortalna stanowiła kryterium wyłączenia w większości badań klinicznych dotyczących TAVI i brakuje dokładnych danych na temat bezpieczeństwa i skuteczności takiego postępowania w tej grupie chorych.
Cel: Celem pracy była ocena bezpieczeństwa i skuteczności TAVI u pacjentów z ciasnym zwężeniem BAV.
Metody: Analizie poddano grupę 104 pacjentów przyjętych do Instytutu Kardiologii w celu wykonania TAVI w okresie od stycznia 2009 r. do maja 2012 r. W ramach kwalifikacji do zabiegu wykonano echokardiograficzne badania przezklatkowe i przezprzełykowe oraz tomografię komputerową serca, aorty i jej rozgałęzień. Odpowiednie pomiary i analiza danych z badań obrazowych umożliwiły wybór optymalnego dostępu przeznaczyniowego, dobranie protezy zastawkowej i właściwe zaplanowanie zabiegu. Dwupłatkową zastawkę aortalną zidentyfikowano u 7 pacjentów (6,7%; średni wiek 77,7 roku), których poddano bardziej szczegółowej analizie. Pacjenci ci mieli zdiagnozowaną ciasną objawową stenozę aortalną ze średnim polem powierzchni przekroju zastawki 0,55 cm2 (0,46–0,7 cm2). Wszyscy zostali zdyskwalifikowani z zabiegu chirurgicznej wymiany zastawki aortalnej ze względu na wysokie ryzyko operacyjne (uśredniony wynik logistic Euroscore 19,9%). Wykonano TAVI z wykorzystaniem systemow CoreValve (5 osób) lub Sapien (2 chorych). Następnie przeanalizowano prospektywne wyniki długoterminowej obserwacji klinicznej i echokardiograficznej w punktach czasowych: 30 dni, 6 miesięcy i 12 miesięcy po zabiegu.
Wyniki: U 1 pacjenta w tomografii komputerowej zaobserwowano eliptyczne zniekształcenie implantowanej protezy, jednak bez istotnej klinicznie dysfunkcji zastawki. Jeden pacjent zmarł w ciągu 30 dni po TAVI z powodu infekcyjnego zapalenia wsierdzia. Pozostali, którzy przeżyli, charakteryzowali się małą do umiarkowanej niedomykalnością aortalną w punkcie czasowym wynoszącym 30 dni. W kolejnych punktach czasowych nie zaobserwowano progresji niedomykalności aortalnej. Po roku od zabiegu 6 spośród 7 pacjentów pozostawało przy życiu. Wszyscy oni osiągnęli istotną poprawę funkcjonalną ocenianą wg klasyfikacji New York Heart Association.
Wnioski: Zabieg TAVI może stanowić alternatywną opcję terapeutyczną dla pacjentów z ciasną stenozą BAV. Według obserwacji autorów niniejszej pracy metoda ta cechuje się względnie niską śmiertelnością i dobrymi wynikami w obserwacji 30-dniowej, 6- oraz 12-miesięcznej.Background: Bicuspid aortic valve (BAV) has been considered a relative contraindication for transcatheter aortic valve implantation (TAVI). Due to more oval shape of the BAV annulus compared to tricuspid aortic valve, the procedure has been discouraged because of an increased risk of stent assembly displacement, uneven expansion, post-procedure paravalvular leakage, stent valve distortion, or other malfunction after implantation. For the same reasons patients with BAV have been excluded from the majority of clinical TAVI trials.
Aim: To evaluate the efficacy and safety of TAVI in patients with BAV stenosis.
Methods: We analysed a group of 104 patients admitted to our institution for TAVI between January 2009 and May 2012. During pre-procedure evaluation, transthoracic and transoesophageal (TEE) echocardiography as well as angio-computed tomography (CT) scan were performed to assess aortic valve anatomy and morphology. Appropriate measurements and detailed analyses of imaging data have been accomplished to select optimal access site, prosthesis size as well as to plan the procedure. BAVs were recorded in seven patients (6.7%; mean age 77.7 years). These patients presented with severe symptomatic aortic valve stenosis with a mean aortic valve area of 0.55 cm2 (0.46–0.7 cm2) as measured in TEE. All of the patients had been disqualified from surgical valve replacement due to high surgical risk with a mean logistic Euroscore of 19.9%. All of them successfully underwent TAVI using CoreValve (n = 5) or Sapien (n = 2) valves. Follow-up was completed at 30 days, and six and 12 months after the procedure.
Results: During follow-up one patient developed an elliptic distortion of the aortic prosthesis in CT, although it did not result in significant malfunctioning of the implant. One patient died of infective endocarditis 30 days after the procedure. Survivors at 30-day follow-up had mild to moderate aortic insufficiency, and it did not deteriorate after six months. At one year follow-up six out of seven patients remained alive. They achieved significant functional improvement by New York Heart Association class compared to baseline.
Conclusions: TAVI may constitute an alternative treatment option for high-risk patients with BAV, resulting in a low periprocedural mortality rate, and good 30-day, six-month, and one-year outcomes
Płaskie elementy pneumatyczne i możliwość ich zastosowania w konstrukcji obiektów mieszkalnych awaryjnych systemów budownictwa
As part of this study, experimental and theoretical investigations into the strength and stiffness of flat pneumatic elements to be used in lightweight dwelling structures, enabling the quick assembly of the latter, were undertaken.
On the basis of the experimentally and theoretically determined parameters of the elements it will be possible to design configurations of spatial pneumatic structures.
In particular, the following were devised and carried out:
a theoretical assessment of the load capacity and stiffness of selected pneumatic elements depending on their dimensions, internal pressure and fixing and support conditions,
an experimental verification of the obtained results.
This study has an exploratory character and constitutes the basis for the design and implementation of original technical, constructional and architectural solutions relating to the application of spatial pneumatic structures in the emergency system.
It should be mentioned that in the known literature on the subject there is no theoretical basis for designing structures whose principal member is a flat pneumatic element.
In the construction industry such structures have not been used so far. An exemplary solution of the spatial dwelling structure has been patented under the name Obiekt mieszkalny (Dwelling facility), (patent no. 131 528, of 18.04.1988).Praca składa się z dwóch części. Pierwsza z nich jest opisowa, druga zaś jest sprawozdaniem z przeprowadzonych badań doświadczalnych. Generalnie, podjęto próbę określenia zakresu tematyki badawczej, której wynikiem byłoby określenie i wyznaczenie wszelkich parametrów dotyczących zarówno własności stosowanego materiału, jak i parametrów geometrycznych elementów konstrukcyjnych pneumatycznych obiektów mieszkalnych.
W szczególności opracowano i wykonano:
teoretyczną ocenę nośności i sztywności wybranych elementów pneumatycznych w zależności od ich wymiarów, ciśnienia wewnętrznego, warunków zamocowania i podparcia,
weryfikację doświadczalną otrzymanych wyników.
Przedstawiona praca ma charakter rozpoznawczy i stanowi podstawę do zaprojektowania i wdrożenia oryginalnych rozwiązań technicznych, konstrukcyjnych i architektonicznych w zakresie zastosowań przestrzennych struktur pneumatycznych do systemu awaryjnego.
Nadmienić trzeba, że w znanej literaturze przedmiotu brak podstaw teoretycznych do projektowania takich struktur, których zasadniczym elementem konstrukcyjnym jest płaski element pneumatyczny.
W budownictwie nie stosuje się dotychczas takich konstrukcji. Przykład rozwiązania przestrzennej struktury mieszkalnej został opatentowany pod nazwą „Obiekt mieszkalny”, (patent nr 131 528, z dnia 18.04.1988)
Odwzorowanie perspektywiczne w iluzyjnym malarstwie nasklepiennym późnego baroku
The following work has shown the analyses carried out in order to clarify facts necessary to understand the phenomenon of the perspective representation in the works of art in Renaissanse and late Baroque. A lot of misunderstandings have arisen on the grounds of critical work made by many theoreticians and art historians. The aim of this work was to stipulate the reasons for the conceptual and methodological fallacies.
Having evaluated the methods used by illusionistic ceiling painters of late Baroque, it was possible to conduct some geometric analyses of the paintings placed on the vault of the Leopoldine Hall at the University of Wrocław.W pracy przedstawiono analizę przyczyn wielu nieporozumień i sporów obecnych w komentarzach, opracowaniach, analizach i opisach historyków i teoretyków sztuki, dotyczących traktatów poświęconych zagadnieniom perspektywy w sztuce renesansu i baroku. Wskazano i zdefiniowano błędy pojęciowe i metodologiczne, jakich dopuszczają się oni w swoich opracowaniach, a także wyjaśniono ich przyczyny.
Przeanalizowano metody pracy artystów okresu późnego baroku specjalizujących się w nasklepiennym malarstwie iluzyjnym. Na tym tle przeprowadzono analizę geometryczną malowideł umieszczonych na sklepieniu Auli Leopoldina Uniwersytetu Wrocławskiego.
 
Fluorescence microscope and scanning electron microscope in study of bacterials biofilm growh
Materiały konferencyjne zostały wydane jako numer specjalny czasopisma "Ochrona przed Korozją - 9s/A/2006".W ciągu ostatnich lat niezwykle dynamicznie rozwijają się nauki łączące zagadnienia medyczne
i inżynierskie. Jednym z efektów obserwowanego postępu jest coraz szerszy zakres wykorzystania
biomateriałów wspomagających funkcje życiowe pacjenta. Obecnie medycyna dysponuje
materiałami o odpowiedniej charakterystyce fizykochemicznej, a także wysokiej biozgodności.
Wciąż jednak obecność implantów może być przyczyną oportunistycznych infekcji bakteryjnych.
Bakterie mogą kolonizować sztuczne elementy, tworząc na ich powierzchni wielowarstwowy
biofilm. W tej postaci skutecznie opierają się działaniu układu odpornościowego oraz antybiotyków
i stają się źródłem wielu zakażeń. Praca przedstawia porównanie dwóch metod obserwacji
bakterii na powierzchniach implantów, wskazując na zalety i ograniczenia stosowania mikroskopii
fluorescencyjnej i elektronowej mikroskopii skaningowej.The one effect of continuous development of medicine is larger range of using biomaterials for aid
functions of patients living. Currently, a medicine has new materials, which are characterized by
adequate for different applications physical and chemical properties and a high biocompatibility.
Still a presence of implant may be a case of opportunity infection. Bacteria can colonies artificial
elements and made on it surfaces multilayer biofilm. In this form biofilm resist human
immunologie system and therapy by drugs and antibiotics. This work shows comparison of two
method of bacteria observation on implants surfaces and it points at advantages and limitations
of used fluorescent microscope and electron-scanning microscope
Barrier Diamond-like Carbon Coatings on Polydimethylsiloxane Substrate
The plasma modification of polydimethylsiloxane (PDMS) substrates is one way to change their surface geometry, which enables the formation of wrinkles. However, these changes are very often accompanied by the process of restoring the hydrophobic properties of the modified material. In this work, the RF PACVD device (radio frequency plasma-assisted chemical vapor deposition) was used, with which the plasma treatment of PDMS substrates was carried out in argon, nitrogen, oxygen, and methane atmospheres at variable negative biases ranging from 100 V to 500 V. The obtained results show the stability of contact angles for deionized water only in the case of surfaces modified by diamond-like carbon (DLC) coatings. The influence of the applied production conditions on the thickness (between 10 and 30 nm) and chemical structure (ID/IG between 0.41 and 0.8) of DLC coatings is discussed. In the case of plasma treatments with other gases introduced into the working chamber, the phenomenon of changing from hydrophilic to hydrophobic properties after the modification processes was observed. The presented results confirm the barrier nature of the DLC coatings produced on the PDMS substrate