Real-Time Electroencephalogram Sonification for Neurofeedback
Electroencephalography (EEG) is the measurement via the scalp of the electrical activity of the brain. The established therapeutic intervention of neurofeedback involves presenting people with their own EEG in real-time to enable them to modify their EEG for purposes of improving performance or health.
The aim of this research is to develop and validate real-time sonifications of EEG for use in neurofeedback and methods for assessing such sonifications. Neurofeedback generally uses a visual display. Where auditory feedback is used, it is mostly limited to pre-recorded sounds triggered by the EEG activity crossing a threshold. However, EEG generates time-series data with meaningful detail at fine temporal resolution and with complex temporal dynamics. Human hearing has a much higher temporal resolution than human vision, and auditory displays do not require people to focus on a screen with their eyes open for extended periods of time – e.g. if they are engaged in some other task. Sonification of EEG could allow more rapid, contingent, salient and temporally detailed feedback. This could improve the efficiency of neurofeedback training and reduce the number and duration of sessions for successful neurofeedback.
The same two deliberately simple sonification techniques were used in all three experiments of this research: Amplitude Modulation (AM) sonification, which maps the fluctuations in the power of the EEG to the volume of a pure tone; and Frequency Modulation (FM) sonification, which uses the changes in the EEG power to modify the frequency. Measures included, a listening task, NASA task load index; a measure of how much work it was to do the task, Pre & post measures of mood, and EEG.
The first experiment used pre-recorded single channel EEG and participants were asked to listen to the sound of the sonified EEG and try and track the activity that they could hear by moving a slider on a computer screen using a computer mouse. This provided a quantitative assessment of how well people could perceive the sonified fluctuations in EEG level. The tracking accuracy scores were higher for the FM sonification but self-assessments of task load rated the AM sonification as easier to track.
The second experiment used the same two sonifications, in a real neurofeedback task using participants own live EEG. Unbeknownst to the participants the neurofeedback task was designed to improve mood. A Pre-Post questionnaire showed that participants changed their self-rated mood in the intended direction with the EEG training, but there was no statistically significant change in EEG. Again the FM sonification showed a better performance but AM was rated as less effortful. The performance of sonifications in the tracking task in experiment 1 was found to predict their relative efficacy at blind self-rated mood modification in experiment 2.
The third experiment used both the tracking as in experiment 1 and neurofeedback tasks as in experiment 2, but with modified versions of the AM and FM sonifications to allow two-channel EEG sonifications. This experiment introduced a physical slider as opposed to a mouse for the tracking task. Tracking accuracy increased, but this time no significant difference was found between the two sonification techniques on the tracking task. In the training task, once more the blind self-rated mood did improve in the intended direction with the EEG training, but as again there was no significant change in EEG, this cannot necessarily be attributed to the neurofeedback. There was only a slight difference between the two sonification techniques in the effort measure.
In this way, a prototype method has been devised and validated for the quantitative assessment of real-time EEG sonifications. Conventional evaluations of neurofeedback techniques are expensive and time consuming. By contrast, this method potentially provides a rapid, objective and efficient method for evaluating the suitability of candidate sonifications for EEG neurofeedback
The fickleness of data: Estimating the effects of different aspects of acupuncture treatment on heart rate variability (HRV). Initial findings from three pilot studies
© 2014 Tony Steffert and David Mayor.Heart rate variability (HRV) is a measure of the interplay between sympathetic and parasympathetic influences on heart rate. Higher HRV is usually associated with relaxation and health benefits, lower HRV with stress/pathology. HRV is used increasingly in acupuncture research. Electroacupuncture (EA) and transcutaneous electrical acupoint stimulation(TEAS) are frequently used variants of manual acupuncture (MA).Peer reviewe
Does the cortical response to electroacupuncture depend on stimulation frequency? Results of a pilot EEG study first proposed at the AACP Conference in 2001
© 2013 Tony Steffert and David Mayor.EEG (electroencephalography) is a low-cost, accessible method of investigating electrical brain activity that is sensitive to rapid changes (unlike fMRI). Electroacupuncture (EA) and Transcutaneous Electrical Acupoint Stimulation (TEAS) are methods of acupuncture-like stimulation. This pilot crossover study, first proposed at the 2001 AACP Conference,1,2 explores the relationship between frequency of TEAS applied peripherally and frequencies of cortical electrical activity detected centrally.Peer reviewe
Expectation and experience of the ‘nonspecific’ effects of acupuncture: Developing and piloting a set of questionnaires
© 2013 David Mayor and Tony Steffert.32-item ‘EXPectation of feelings’ questionnaires were developed to explore the expected (EXPre) and reported (EXPost) incidence of ‘nonspecific’ (whole person) feelings in response to acupuncture-type interventions, in particular electroacupuncture (EA) and transcutaneous electrical acupoint stimulation (TEAS). They were tested on 204 participants familiar with acupuncture in three separate cohorts (Pilot, CPD, Students). Their validity and reliability were assessed, a cluster analysis conducted, and the association between expectation and experience analysed, along with those items most frequently found, association with other trait and state measures, and the influence of various aspects of treatments on reported feelings. Results are briefly reported in our poster. Methods and further detailed material are provided in the online background information.Peer reviewedFinal Published versio
Efficient Methods for Calculating Sample Entropy in Time Series Data Analysis
Recently, different algorithms have been suggested to improve Sample Entropy (SE) performance. Although new methods for calculating SE have been proposed, so far improving the efficiency (computational time) of SE calculation methods has not been considered. This research shows such an analysis of calculating a correlation between Electroencephalogram(EEG) and Heart Rate Variability(HRV) based on their SE values. Our results indicate that the parsimonious outcome of SE calculation can be achieved by exploiting a new method of SE implementation. In addition, it is found that the electrical activity in the frontal lobe of the brain appears to be correlated with the HRV in a time domain.Peer reviewe
Changes in finger temperature and blood flow in response to different frequencies of transcutaneous electroacupuncture at LI4 (hegu)
© 2015 David Mayor, Tony Steffert and Ronakben Bhavsar.Background. Finger blood flow and temperature are often used as indices of autonomic (sympathetic) function. Transcutaneous electroacupuncture (TEA) is an increasingly used variant of electroacupuncture (EA). This is the fifth in a series of conference posters from a study investigating the effects of EA and TEA on heart/pulse rate variability (HRV/PRV), the electroencephalograph (EEG), and now blood flow.Peer reviewe
Prototyping a method for the assessment of real-time EEG sonifications
This paper presents a first step in the development of a methodology to compare the ability of different sonifications to convey the fine temporal detail of the Electroencephalography (EEG) brainwave signal in real time. In EEG neurofeedback a person‟s EEG activity is monitored and presented back to them, to help them to learn how to modify their brain activity. Learning theory suggests that the more rapidly and accurately the feedback follows behaviour the more efficient the learning will be. Therefore a critical issue is how to assess the ability of a sonification to convey rapid and temporally complex EEG data for neurofeedback.
To allow for replication, this study used sonifications of pre-recorded EEG data and asked participants to try and track aspects of the signal in real time using a mouse.
This study showed that, although imperfect, this approach is a practical way to compare the suitability of EEG sonifications for tracking detailed EEG signals in real time and that the combination of quantitative and qualitative data helped characterise the relative efficacy of different sonifications
Recommended from our members
CEPS: An Open Access MATLAB Graphical User Interface (GUI) for the Analysis of Complexity and Entropy in Physiological Signals
Background: We developed CEPS as an open access MATLAB® GUI (graphical user interface) for the analysis of Complexity and Entropy in Physiological Signals (CEPS), and demonstrate its use with an example data set that shows the effects of paced breathing (PB) on variability of heart, pulse and respiration rates. CEPS is also sufficiently adaptable to be used for other time series physiological data such as EEG (electroencephalography), postural sway or temperature measurements. Methods: Data were collected from a convenience sample of nine healthy adults in a pilot for a larger study investigating the effects on vagal tone of breathing paced at various different rates, part of a development programme for a home training stress reduction system. Results: The current version of CEPS focuses on those complexity and entropy measures that appear most frequently in the literature, together with some recently introduced entropy measures which may have advantages over those that are more established. Ten methods of estimating data complexity are currently included, and some 28 entropy measures. The GUI also includes a section for data pre-processing and standard ancillary methods to enable parameter estimation of embedding dimension m and time delay τ (‘tau’) where required. The software is freely available under version 3 of the GNU Lesser General Public License (LGPLv3) for non-commercial users. CEPS can be downloaded at https://bitbucket.org/deepak_panday/ceps/src/pipeline_v2/. In our illustration on PB, most complexity and entropy measures decreased significantly in response to breathing at 7 breaths per minute, differentiating more clearly than conventional linear, time- and frequency-domain measures between breathing states. In contrast, Higuchi fractal dimension increased during paced breathing. Conclusions: We have developed CEPS software as a physiological data visualiser able to integrate state of the art techniques. The interface is designed for clinical research and has a structure designed for integrating new tools. The aim is to strengthen collaboration between clinicians and the biomedical community, as demonstrated here by using CEPS to analyse various physiological responses to paced breathing
Complexity and Entropy in Physiological Signals (CEPS): Resonance Breathing Rate Assessed Using Measures of Fractal Dimension, Heart Rate Asymmetry and Permutation Entropy
Background: As technology becomes more sophisticated, more accessible methods of interpretating Big Data become essential. We have continued to develop Complexity and Entropy in Physiological Signals (CEPS) as an open access MATLAB® GUI (graphical user interface) providing multiple methods for the modification and analysis of physiological data. Methods: To demonstrate the functionality of the software, data were collected from 44 healthy adults for a study investigating the effects on vagal tone of breathing paced at five different rates, as well as self-paced and un-paced. Five-minute 15-s recordings were used. Results were also compared with those from shorter segments of the data. Electrocardiogram (ECG), electrodermal activity (EDA) and Respiration (RSP) data were recorded. Particular attention was paid to COVID risk mitigation, and to parameter tuning for the CEPS measures. For comparison, data were processed using Kubios HRV, RR-APET and DynamicalSystems.jl software. We also compared findings for ECG RR interval (RRi) data resampled at 4 Hz (4R) or 10 Hz (10R), and non-resampled (noR). In total, we used around 190–220 measures from CEPS at various scales, depending on the analysis undertaken, with our investigation focused on three families of measures: 22 fractal dimension (FD) measures, 40 heart rate asymmetries or measures derived from Poincaré plots (HRA), and 8 measures based on permutation entropy (PE). Results: FDs for the RRi data differentiated strongly between breathing rates, whether data were resampled or not, increasing between 5 and 7 breaths per minute (BrPM). Largest effect sizes for RRi (4R and noR) differentiation between breathing rates were found for the PE-based measures. Measures that both differentiated well between breathing rates and were consistent across different RRi data lengths (1–5 min) included five PE-based (noR) and three FDs (4R). Of the top 12 measures with short-data values consistently within ± 5% of their values for the 5-min data, five were FDs, one was PE-based, and none were HRAs. Effect sizes were usually greater for CEPS measures than for those implemented in DynamicalSystems.jl. Conclusion: The updated CEPS software enables visualisation and analysis of multichannel physiological data using a variety of established and recently introduced complexity entropy measures. Although equal resampling is theoretically important for FD estimation, it appears that FD measures may also be usefully applied to non-resampled data
Proceedings of Abstracts Engineering and Computer Science Research Conference 2019
© 2019 The Author(s). This is an open-access work distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. For further details please see https://creativecommons.org/licenses/by/4.0/. Note: Keynote: Fluorescence visualisation to evaluate effectiveness of personal protective equipment for infection control is © 2019 Crown copyright and so is licensed under the Open Government Licence v3.0. Under this licence users are permitted to copy, publish, distribute and transmit the Information; adapt the Information; exploit the Information commercially and non-commercially for example, by combining it with other Information, or by including it in your own product or application. Where you do any of the above you must acknowledge the source of the Information in your product or application by including or linking to any attribution statement specified by the Information Provider(s) and, where possible, provide a link to this licence: http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/This book is the record of abstracts submitted and accepted for presentation at the Inaugural Engineering and Computer Science Research Conference held 17th April 2019 at the University of Hertfordshire, Hatfield, UK. This conference is a local event aiming at bringing together the research students, staff and eminent external guests to celebrate Engineering and Computer Science Research at the University of Hertfordshire. The ECS Research Conference aims to showcase the broad landscape of research taking place in the School of Engineering and Computer Science. The 2019 conference was articulated around three topical cross-disciplinary themes: Make and Preserve the Future; Connect the People and Cities; and Protect and Care