126 research outputs found
Design-related risk factors for revision of primary cemented stems: Analysis of 3 common stems in the Swedish Hip Arthroplasty Register
A modular cementless stem vs. cemented long-stem prostheses in revision surgery of the hip: A population-based study from the Swedish Hip Arthroplasty Register
Overdose prevention training with naloxone distribution in a prison in Oslo, Norway: a preliminary study
What People Believe about How Memory Works: A Representative Survey of the U.S. Population
Incorrect beliefs about the properties of memory have broad implications: The media conflate normal forgetting and inadvertent memory distortion with intentional deceit, juries issue verdicts based on flawed intuitions about the accuracy and confidence of testimony, and students misunderstand the role of memory in learning. We conducted a large representative telephone survey of the U.S. population to assess common beliefs about the properties of memory. Substantial numbers of respondents agreed with propositions that conflict with expert consensus: Amnesia results in the inability to remember one's own identity (83% of respondents agreed), unexpected objects generally grab attention (78%), memory works like a video camera (63%), memory can be enhanced through hypnosis (55%), memory is permanent (48%), and the testimony of a single confident eyewitness should be enough to convict a criminal defendant (37%). This discrepancy between popular belief and scientific consensus has implications from the classroom to the courtroom
Mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components: a retrospective study
Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up
Background
Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up.
Materials and methods
Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe’s classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10–14 years).
Results
Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised.
Conclusions
Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results
Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
Clinical aspects of a phase I trial of 5,6-dimethylxanthenone-4-acetic acid (DMXAA), a novel antivascular agent
Basic Science Considerations in Primary Total Hip Replacement Arthroplasty
Total Hip Replacement is one of the most common operations performed in the developed world today. An increasingly ageing population means that the numbers of people undergoing this operation is set to rise. There are a numerous number of prosthesis on the market and it is often difficult to choose between them. It is therefore necessary to have a good understanding of the basic scientific principles in Total Hip Replacement and the evidence base underpinning them. This paper reviews the relevant anatomical and biomechanical principles in THA. It goes on to elaborate on the structural properties of materials used in modern implants and looks at the evidence base for different types of fixation including cemented and uncemented components. Modern bearing surfaces are discussed in addition to the scientific basis of various surface engineering modifications in THA prostheses. The basic science considerations in component alignment and abductor tension are also discussed. A brief discussion on modular and custom designs of THR is also included. This article reviews basic science concepts and the rationale underpinning the use of the femoral and acetabular component in total hip replacement
More complications in uncemented compared to cemented hemiarthroplasty for displaced femoral neck fractures: a randomized controlled trial of 201 patients, with one year follow-up
- …