1,765 research outputs found

    A new methodology for the quantitative visualization of coherent flow structures in alluvial channels using multibeam echo-sounding (MBES)

    Get PDF
    In order to investigate the interactions between turbulence and suspended sediment transport in natural aqueous environments, we ideally require a technique that allows simultaneous measurement of fluid velocity and sediment concentration for the whole flow field. Here, we report on development of a methodology using the water column acoustic backscatter signal from a multibeam echo sounder to simultaneously quantify flow velocities and sediment concentrations. The application of this new technique is illustrated with reference to flow over the leeside of an alluvial sand dune, which allows, for the first time in a field study, quantitative visualization of large-scale, whole flow field, turbulent coherent flow structures associated with the dune leeside that are responsible for suspending bed sediment. This methodology holds great potential for use in a wide range of aqueous geophysical flows

    Symptom management in amyotrophic lateral sclerosis: We can do better

    Full text link
    Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/141321/1/mus25740_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/141321/2/mus25740.pd

    Method for Accurately Calibrating a Spectrometer Using Broadband Light

    Get PDF
    A novel method has been developed for performing very fine calibration of a spectrometer. This process is particularly useful for modern miniature charge-coupled device (CCD) spectrometers where a typical factory wavelength calibration has been performed and a finer, more accurate calibration is desired. Typically, the factory calibration is done with a spectral line source that generates light at known wavelengths, allowing specific pixels in the CCD array to be assigned wavelength values. This method is good to about 1 nm across the spectrometer s wavelength range. This new method appears to be accurate to about 0.1 nm, a factor of ten improvement. White light is passed through an unbalanced Michelson interferometer, producing an optical signal with significant spectral variation. A simple theory can be developed to describe this spectral pattern, so by comparing the actual spectrometer output against this predicted pattern, errors in the wavelength assignment made by the spectrometer can be determined

    Apparatus and method for high-speed characterization of surfaces

    Get PDF
    This invention permits rapid determination of a three-dimensional contour of an object. The apparatus directs a laser beam onto a point on an object, and the scattered light is received by a position sensitive detector (PSD). The location at which scattered light is received can be related to the displacement of the point on the object, using basic trigonometry. The laser beam is deflected non-mechanically, by passing it through a crystal whose index of refraction is varied in a controlled manner. By proper control of the index of refraction, one can scan the beam across a desired area of the object, without using any moving parts, and can therefore obtain complete information about the contour of the object. The device operates without making any conventional images, and is therefore much faster than comparable devices of the prior art. Also, the laser and beam deflector can be housed in a small optical head which enables the device to reach normally inaccessible areas. The device can compare the test object with a reference object, or it can compare two objects for differences

    A bibliographical review of research completed by Nepali students at Lincoln University, New Zealand (1956 - 2022)

    Get PDF
    Not long after the summiting of Everest in May 1953, Bidur Kumar Thapa, the first recorded Nepali student arrived at the then Lincoln Agricultural College, supported by the Colombo Plan. He graduated in 1956 with a Masters of Agricultural Science with Honours in Soil Science under the supervision of Dr Walker, and went on to publish his findings on grassland soils in the Journal of Soil Science, in 1959. Thapa’s work laid the foundation and pathway for future students from Nepal. In the following years, more than fifty Nepali research students have been recorded in the Lincoln University archives as completing a range of research-based qualifications from across the University, and in many instances going on to publish findings in scholarly journals. This annotated bibliography sets out to collate, review and curate their collective research efforts spanning almost seventy years

    Handheld White Light Interferometer for Measuring Defect Depth in Windows

    Get PDF
    Accurate quantification of defects (scratches and impacts) is vital to the certification of flight hardware and other critical components. The amount of damage to a particular component contributes to the performance, reliability, and safety of a system, which ultimately affects the success or failure of a mission or test. The launch-commit criteria on a Space Shuttle Orbiter window are governed by the depth of the defects that are identified by a visual inspection. This measurement of a defect is not easy to obtain given the environment, size of the defect, and location of the window(s). The determination of depth has typically been performed by taking a mold impression and measuring the impression with an optical profiling instrument. Another method of obtaining an estimate of the depth is by using a refocus microscope. To use a refocus microscope, the surface of the glass and bottom of the defect are, in turn, brought into focus by the operator. The amount of movement between the two points corresponds to the depth of the defect. The refocus microscope requires a skilled operator and has been proven to be unreliable when used on Orbiter windows. White light interferometry was chosen as a candidate to replace the refocus microscope. The White Light Interferometer (WLI) was developed to replace the refocus microscope as the instrument used for measuring the depth of defects in Orbiter windows. The WLI consists of a broadband illumination source, interferometer, detector, motion control, displacement sensor, mechanical housing, and support electronics. The illumination source for the WLI is typically a visible light emitting diode (LED) or a near-infrared superluminescent diode (SLD) with power levels of less than a milliwatt. The interferometer is a Michelson configuration consisting of a 1-in. (2.5-cm) cube beam splitter, a 0.5-in. (1.3-cm) optical window as a movable leg (used to closely match the return intensity of the fixed leg from the window), and a mirrored prism to fold the optics into the mechanical housing. The detector may be one of many C-mount CCD (charge-coupled device) cameras. Motion is provided by a commercial nanostepping motor with a serial interface. The displacement sensor is a custom device specifically designed for this application. The mechanical housing and support electronics were designed to integrate the various components into an instrument that could be physically handled by a technician and easily transported

    Inductive Position Sensor

    Get PDF
    An inductive position sensor uses three independent inductors inductively coupled by a common medium such as air. First and second inductors are separated by a fixed distance with the first inductor's axial core and second inductor's axial core maintained parallel to one another. A third inductor is disposed between the first and second inductors with the third inductor's axial core being maintained parallel to those of the first and second inductors. The combination of the first and second inductors are configured for relative movement with the third inductor's axial core remaining parallel to those of the first and second inductors as distance changes from the third inductor to each of the first inductor and second inductor. An oscillating current can be supplied to at least one of the three inductors, while voltage induced in at least one of the three inductors not supplied with the oscillating current is measured

    Inductive Non-Contact Position Sensor

    Get PDF
    Optical hardware has been developed to measure the depth of defects in the Space Shuttle Orbiter's windows. In this hardware, a mirror is translated such that its position corresponds to the defect's depth, so the depth measurement problem is transferred to a mirror-position measurement problem. This is preferable because the mirror is internal to the optical system and thus accessible. Based on requirements supplied by the window inspectors, the depth of the defects needs to be measured over a range of 200 microns with a resolution of about 100 nm and an accuracy of about 400 nm. These same requirements then apply to measuring the position of the mirror, and in addition, since this is a scanning system, a response time of about 10 ms is needed. A market search was conducted and no sensor that met these requirements that also fit into the available housing volume (less than one cubic inch) was found, so a novel sensor configuration was constructed to meet the requirements. This new sensor generates a nearly linearly varying magnetic field over a small region of space, which can easily be sampled, resulting in a voltage proportional to position. Experiments were done with a range of inductor values, drive voltages, drive frequencies, and inductor shapes. A rough mathematical model was developed for the device that, in most aspects, describes how it operates and what electrical parameters should be chosen for best performance. The final configuration met all the requirements, yielding a small rugged sensor that was easy to use and had nanometer resolution over more than the 200-micron range required. The inductive position sensor is a compact device (potentially as small as 2 cubic centimeters), which offers nanometer-position resolution over a demonstrated range of nearly 1 mm. One of its advantages is the simplicity of its electrical design. Also, the sensor resolution is nearly uniform across its operational range, which is in contrast to eddy current and capacitive sensors whose sensitivity is dependent upon position
    corecore