12 research outputs found
Radiometric Characterization of IKONOS Multispectral Imagery
A radiometric characterization of Space Imaging's IKONOS 4-m multispectral imagery has been performed by a NASA funded team from the John C. Stennis Space Center (SSC), the University of Arizona Remote Sensing Group (UARSG), and South Dakota State University (SDSU). Both intrinsic radiometry and the effects of Space Imaging processing on radiometry were investigated. Relative radiometry was examined with uniform Antarctic and Saharan sites. Absolute radiometric calibration was performed using reflectance-based vicarious calibration methods on several uniform sites imaged by IKONOS, coincident with ground-based surface and atmospheric measurements. Ground-based data and the IKONOS spectral response function served as input to radiative transfer codes to generate a Top-of-Atmosphere radiance estimate. Calibration coefficients derived from each vicarious calibration were combined to generate an IKONOS radiometric gain coefficient for each multispectral band assuming a linear response over the full dynamic range of the instrument. These calibration coefficients were made available to Space Imaging, which subsequently adopted them by updating its initial set of calibration coefficients. IKONOS imagery procured through the NASA Scientific Data Purchase program is processed with or without a Modulation Transfer Function Compensation kernel. The radiometric effects of this kernel on various scene types was also investigated. All imagery characterized was procured through the NASA Scientific Data Purchase program
Phase I Study of Adenovirus p53 Administered by Bronchoalveolar Lavage in Patients With Bronchioloalveolar Cell Lung Carcinoma: ECOG 6597
PURPOSE: This pilot phase I trial evaluated the safety and maximum-tolerated dose of p53 gene transfer using an adenovirus vector (Ad-p53) delivered via bronchoalveolar lavage (BAL) to patients with bronchioloalveolar lung carcinoma (BAC).
PATIENTS AND METHODS: Patients were initially administered two treatments of Ad-p53 to a single involved lobe, beginning at 2 x 10(9) viral particles (vp) per dose and escalated to a maximum of 2 x 10(12) vp. If a clinical benefit was seen and the treatment was well tolerated, additional doses could be administered to additional lobes.
RESULTS: Twenty-five patients were treated at doses between 2 x 10(9) and 2 x 10(12) vp. At 2 x 10(12) vp, one patient experienced grade 4 pulmonary toxicity, and one patient died 25 days after his second cycle; therefore, a cohort of 10 patients was treated at the recommended phase II dose of 5 x 10(11) vp, with no grade 4 toxicity observed. The most frequent toxicities included low-grade fever, hypoxia, and dyspnea. Of the 23 assessable patients, 16 had stable disease as their best response. Subjective improvement in breathing was noted in eight patients. Limited distribution of vector was observed, with transient detection in patient sputum for 1 to 2 days after administration.
CONCLUSION: Ad-p53 can be administered safely by BAL at 5 x 10(11) vp with repeated dosing. Stabilization of disease and symptomatic improvement may warrant further studies of Ad-p53 or other adenoviruses administered by BAL in patients with BAC
Preoperative Ultrasound Assessment of Regional Lymph Nodes in Melanoma Patients Does not Provide Reliable Nodal Staging: Results from a Large Multicenter Trial.
OBJECTIVE: To assess whether preoperative ultrasound (US) assessment of regional lymph nodes in patients who present with primary cutaneous melanoma provides accurate staging.
BACKGROUND: It has been suggested that preoperative US could avoid the need for sentinel node (SN) biopsy, but in most single-institution reports, the sensitivity of preoperative US has been low.
METHODS: Preoperative US data and SNB results were analyzed for patients enrolled at 20 centers participating in the screening phase of the second Multicenter Selective Lymphadenectomy Trial. Excised SNs were histopathologically assessed and considered positive if any melanoma was seen.
RESULTS: SNs were identified and removed from 2859 patients who had preoperative US evaluation. Among those patients, 548 had SN metastases. US was positive (abnormal) in 87 patients (3.0%). Among SN-positive patients, 39 (7.1%) had an abnormal US. When analyzed by lymph node basin, 3302 basins were evaluated, and 38 were true positive (1.2%). By basin, the sensitivity of US was 6.6% (95% confidence interval: 4.6-8.7) and the specificity 98.0% (95% CI: 97.5-98.5). Median cross-sectional area of all SN metastases was 0.13 mm; in US true-positive nodes, it was 6.8 mm. US sensitivity increased with increasing Breslow thickness of the primary melanoma (0% for ≤1 mm thickness, 11.9% for \u3e4 mm thickness). US sensitivity was not significantly greater with higher trial center volume or with pre-US lymphoscintigraphy.
CONCLUSION: In the MSLT-II screening phase population, SN tumor volume was usually too small to be reliably detected by US. For accurate nodal staging to guide the management of melanoma patients, US is not an effective substitute for SN biopsy
Preoperative Ultrasound Assessment of Regional Lymph Nodes in Melanoma Patients Does not Provide Reliable Nodal Staging Results From a Large Multicenter Trial
Objective: To assess whether preoperative ultrasound (US) assessment of regional lymph nodes in patients who present with primary cutaneous melanoma provides accurate staging. Background: It has been suggested that preoperative US could avoid the need for sentinel node (SN) biopsy, but in most single-institution reports, the sensitivity of preoperative US has been low. Methods: Preoperative US data and SNB results were analyzed for patients enrolled at 20 centers participating in the screening phase of the second Multicenter Selective Lymphadenectomy Trial. Excised SNs were histopathologically assessed and considered positive if any melanoma was seen. Results: SNs were identified and removed from 2859 patients who had preoperative US evaluation. Among those patients, 548 had SN metastases. US was positive (abnormal) in 87 patients (3.0%). Among SN-positive patients, 39 (7.1%) had an abnormal US. When analyzed by lymph node basin, 3302 basins were evaluated, and 38 were true positive (1.2%). By basin, the sensitivity of US was 6.6% (95% confidence interval: 4.6-8.7) and the specificity 98.0% (95% CI: 97.5-98.5). Median cross-sectional area of all SN metastases was 0.13 mm(2); in US true-positive nodes, it was 6.8 mm(2). US sensitivity increased with increasing Breslow thickness of the primary melanoma (0% for 4 mm thickness). US sensitivity was not significantly greater with higher trial center volume or with pre-US lymphoscintigraphy. Conclusion: In the MSLT-II screening phase population, SN tumor volume was usually too small to be reliably detected by US. For accurate nodal staging to guide the management of melanoma patients, US is not an effective substitute for SN biopsy