761 research outputs found

    An innovative technique for the investigation of the 4-fold forbidden beta-decay of 50^{50}V

    Full text link
    For the first time a Vanadium-based crystal was operated as cryogenic particle detector. The scintillating low temperature calorimetric technique was used for the characterization of a 22 g YVO4_4 crystal aiming at the investigation of the 4-fold forbidden non-unique β−\beta^- decay of 50^{50}V. The excellent bolometric performance of the compound together with high light output of the crystal makes it an outstanding technique for the study of such elusive rate process. The internal radioactive contaminations of the crystal are also investigated showing that an improvement on the current status of material selection and purification are needed, 235/238^{235/238}U and 232^{232}Th are measured at the level of 28 mBq/kg, 1.3 Bq/kg and 28 mBq/kg, respectively. In this work, we also discuss a future upgrade of the experimental set-up which may pave the road for the detection of the rare 50^{50}V β−\beta^- decay

    A new investigation of half-lives for the decay modes of 50^{50}V

    Get PDF
    A new search for the decay modes of the 4-fold forbidden non-unique decay of 50^{50}V has been performed at the Gran Sasso Underground Laboratory (LNGS). In total an exposure of 197 kg ×\times d has been accumulated. The half-life for the electron capture into the first excited state of 50^{50}Ti has been measured with the highest precision to date as 2.67−0.18+0.16×10172.67_{-0.18}^{+0.16} \times 10^{17} yr (68% C.I.) in which systematics uncertainties dominate. The search for the β\beta-decay into the first excited state of 50^{50}Cr resulted in a lower limit of 1.9×1019{1.9} \times 10^{19} yr (90% C.I.), which is an improvement of almost one order of magnitude compared to existing results. The sensitivity of the new measurement is now in the region of theoretical predictions

    Hemostatic Agents for the Management of Bleeding Risk Associated with Oral Anticoagulant Therapy Following Tooth Extraction: A Systematic Review

    Get PDF
    The occurrence of bleeding following dental extraction is a relatively common complication. A history of therapy with oral anticoagulants represents a major favoring factor, both in patients treated with vitamin K-antagonists (especially warfarin) and with direct oral anticoagulants (DOACs). Several local hemostatic measures can be applied to limit the bleeding risk in these patients. The aim of this systematic review is to evaluate what measures can be adopted to limit the bleeding risk following dental extractions in patients treated with oral anticoagulants. A literature search was performed, and 116 articles were retrieved. Titles and abstract analyses excluded 91 articles, and three more articles were excluded following full-text analysis. The systematic review was performed on 22 articles. Among the included articles, 20 studies reported on patients treated with warfarin, and two studies on patients treated with DOACs. The agents employed included local intra-alveolar agents, tranexamic acid, and PRF. The included studies were all at moderate/high risk of bias. Moreover, limited evidence is available on hemostasis in patients treated with DOACs. The available evidence hinders stating the superiority of one agent over the others. Further research is advised to increase the level of evidence of the application of hemostatic agents in patients treated with oral anticoagulants

    Copper electroforming service at Laboratorio Subterráneo de Canfranc

    Get PDF
    Electroforming of copper can be very effective to obtain high radio-purity copper parts for low-background experiments. To support the construction of experiments at the Laboratorio Subterráneo de Canfranc in Spain, a Copper Electroforming Service (CES) set-up is in operation. In this work the electroforming system is described and results on the radio-purity of parts made are presented

    Relativistic electrons from sparks in the laboratory

    Get PDF
    Discharge experiments were carried out at the Eindhoven University of Technology in 2013. The experimental setup was designed to search for electrons produced in meter-scale sparks using a 1 MV Marx generator. Negative voltage was applied to the high voltage (HV) electrode. Five thin (1 mm) plastic detectors (5 cm2\rm cm^2 each) were distributed in various configurations close to the spark gap. Earlier studies have shown (for HV negative) that X-rays are produced when a cloud of streamers is developed 30-60 cm from the negative electrode. This indicates that the electrons producing the X-rays are also accelerated at this location, that could be in the strong electric field from counterstreamers of opposite polarity. Comparing our measurements with modeling results, we find that ∼\sim300 keV electrons produced about 30-60 cm from the negative electrode are the most likely source of our measurements. A statistical analysis of expected detection of photon bursts by these fiber detectors indicates that only 20%-45% of the detected bursts could be from soft (∼\sim10 keV) photons, which further supports that the majority of detected bursts are produced by relativistic electrons

    Updated and novel limits on double beta decay and dark matter-induced processes in platinum

    Full text link
    A 510 day long-term measurement of a 45.3 g platinum foil acting as the sample and high voltage contact in an ultra-low-background high purity germanium detector was performed at Laboratori Nazionali del Gran Sasso (Italy). The data was used for a detailed study of double beta decay modes in natural platinum isotopes. Limits are produced in the range O(1014−1017)\mathcal{O}(10^{14} - 10^{17}) a for double beta decay to excited states (90% C.L.) confirming, and partially extending existing limits. The highest sensitivity, greater than 101710^{17} a, was achieved for the 2ν2\nu and resonant 0ν0\nu modes of double electron capture involving KL shell electrons. Additionally, novel limits for inelastic dark matter scattering on 195^{195}Pt are placed up to mass splittings of approximately 500 keV. We analyze several techniques to extend the sensitivity and propose a few approaches for future medium-scale experiments with platinum-group elements.Comment: 15 pages, 3 figure

    Sustainable Production of Stiff and Crystalline Bacterial Cellulose from Orange Peel Extract

    Get PDF
    In this work, a potentially economic and environmentally friendly method for the synthesis of bacterial cellulose (BC) by Gluconacetobacter xylinus from a biomass containing orange peel extract was evaluated. Orange peel extract was used as a culture medium without any hydrolysis treatment, thus speeding up the synthesis procedure. The efficacy of orange peel as a carbon source was compared with that of sucrose. The orange peel extract formed thicker cellulose gels than those formed using sucrose. X-ray diffraction (XRD) revealed both a high crystallinity index and crystallite size of BC nanofibers in samples obtained from orange peel (BC_Orange). Field emission scanning electron microscopy (FE-SEM) revealed a highly densely packed nanofibrous structure (50 nm in diameter). BC_Orange presented a two-fold increase in water holding capacity (WHC), and dynamic mechanical analysis (DMA) showed a 44% increase in storage modulus compared to sucrose derived BC. These results showed that the naturally available carbon sources derived from orange peel extract can be effectively used for BC production. The orange-based culture medium can be considered a profitable alternative to the generation of high-value products in a virtuous circular economy model

    New experimental limits on the alpha decays of lead isotopes

    Full text link
    For the first time a PbWO4 crystal was grown using ancient Roman lead and it was run as a cryogenic detector. Thanks to the simultaneous and independent read-out of heat and scintillation light, the detector was able to discriminate beta/gamma interactions with respect to alpha particles down to low energies. New more stringent limits on the alpha decays of the lead isotopes are presented. In particular a limit of T_{1/2} > 1.4*10^20 y at a 90% C.L. was evaluated for the alpha decay of 204Pb to 200Hg
    • …
    corecore