3,106 research outputs found

    Dimuon production by protons in Tungsten

    Full text link
    The mass spectrum of dimuons produced by 400 GeV/c protons in Tungsten has been measured for masses greater than 7 GeV. A clear resonant signal of 2700 upsilons has been seen. The dependence of dimuon production on xF and pT has been determined for dimuon masses in the range 7.0 to 8.25 GeV as well as for masses in the upsilon region 8.25 to 9.75 GeV.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87470/2/93_1.pd

    Electron neutrino tagging through tertiary lepton detection

    Get PDF
    We discuss an experimental technique aimed at tagging electron neutrinos in multi-GeV artificial sources on an event-by-event basis. It exploits in a novel manner calorimetric and tracking technologies developed in the framework of the LHC experiments and of rare kaon decay searches. The setup is suited for slow-extraction, moderate power beams and it is based on an instrumented decay tunnel equipped with tagging units that intercept secondary and tertiary leptons from the bulk of undecayed \pi^+ and protons. We show that the taggers are able to reduce the \nue contamination originating from K_e3 decays by about one order of magnitude. Only a limited suppression (~60%) is achieved for \nue produced by the decay-in-flight of muons; for low beam powers, similar performance as for K_e3 can be reached supplementing the tagging system with an instrumented beam dump.Comment: 19 pages, 7 figures; minor changes, version to appear in EPJ

    The validity, reliability and minimal clinically important difference of the patient specific functional scale in snake envenomation

    Get PDF
    Objective: Valid, reliable, and clinically relevant outcome measures are necessary in clinical studies of snake envenomation. The aim of this study was to evaluate the psychometric (validity and reliability) and clinimetric (minimal clinically important difference [MCID]) properties of the Patient-Specific Functional Scale (PSFS) in snakebite envenomation. Methods: We performed a secondary analysis of two existing snakebite trials that measured clinical outcomes using the PSFS as well as other quality of life and functional assessments. Data were collected at 3, 7, 10, and 17 days. Reliability was determined using Cronbach’s alpha for internal consistency and the intraclass correlation coefficient (ICC) for temporal stability at 10 and 17 days. Validity was assessed using concurrent validity correlating with the other assessments. The MCID was evaluated using the following criteria: (1) the distribution of stable patients according to both standard error of measurement (SEM) and responsiveness techniques, and (2) anchor-based methods to compare between individuals and to detect discriminant ability of a positive change with a receiver operator characteristic (ROC) curve and optimal cutoff point. Results: A total of 86 patients were evaluated in this study. The average PSFS scores were 5.37 (SD 3.23), 7.95 (SD 2.22), and 9.12 (SD 1.37) at 3, 7, and 10 days, respectively. Negligible floor effect was observed (maximum of 8% at 3 days); however, a ceiling effect was observed at 17 days (25%). The PSFS showed good reliability with an internal consistency of 0.91 (Cronbach’s alpha) (95% CI 0.88, 0.95) and a temporal stability of 0.83 (ICC) (95% CI 0.72, 0.89). The PSFS showed a strong positive correlation with quality of life and functional assessments. The MCID was approximately 1.0 for all methods. Conclusions: With an MCID of approximately 1 point, the PSFS is a valid and reliable tool to assess quality of life and functionality in patients with snake envenomation

    The Efficacy of Crotalidae Polyvalent Immune Fab (Ovine) Antivenom Versus Placebo Plus Optional Rescue Therapy on Recovery From Copperhead Snake Envenomation: A Randomized, Double-Blind, Placebo-Controlled, Clinical Trial

    Get PDF
    Study objective: Copperhead snake (Agkistrodon contortrix) envenomation causes limb injury resulting in pain and disability. It is not known whether antivenom administration improves limb function. We determine whether administration of antivenom improves recovery from limb injury in patients envenomated by copperhead snakes. Methods: From August 2013 through November 2015, we performed a multicenter, randomized, double-blind, placebo- controlled, clinical trial to evaluate the effect of ovine Crotalidae polyvalent immune Fab (ovine) (CroFab; FabAV) antivenom therapy on recovery of limb function in patients with copperhead snake envenomation at 14 days postenvenomation. The study setting was 18 emergency departments in regions of the United States where copperhead snakes are endemic. Consecutive patients aged 12 years or older with mild- to moderate-severity envenomation received either FabAV or placebo. The primary outcome was limb function 14 days after envenomation, measured by the Patient-Specific Functional Scale. Additional outcomes included the Patient-Specific Functional Scale at other points; the Disorders of the Arm, Shoulder, and Hand, Lower Extremity Functional Scale, and Patient’s Global Impression of Change instruments; grip strength; walking speed; quality of life (Patient-Reported Outcomes Measurement Information System Physical Fucntion-10); pain; and analgesic use. Results: Seventy-four patients received study drug (45 FabAV, 29 placebo). Mean age was 43 years (range 12 to 86 years). Fifty-three percent were men, 62% had lower extremity envenomation, and 88% had mild initial severity. The primary outcome, the least square mean Patient-Specific Functional Scale score at 14 days postenvenomation, was 8.6 for FabAV-treated subjects and 7.4 for placebo recipients (difference 1.2; 95% confidence interval 0.1 to 2.3; P1�4.04). Additional outcome assessments generally favored FabAV. More FabAV-treated subjects experienced treatment- emergent adverse events (56% versus 28%), but few were serious (1 in each group). Conclusion: Treatment with FabAV reduces limb disability measured by the Patient-Specific Functional Scale 14 days after copperhead envenomation. [Ann Emerg Med. 2017;70:233-244.

    Relative luminosity measurement of the LHC with the ATLAS forward calorimeter

    Full text link
    In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the ATLAS detector. The method was verified with a reproduction of a small section of the ATLAS forward calorimeter using proton beams of known beam energies and variable intensities at the U-70 accelerator at IHEP in Protvino, Russia. The experimental setup and the data taking during a test beam run in April 2008 are described in detail. A comparison of the measured high voltage currents with reference measurements from beam intensity monitors shows a linear dependence on the beam intensity. The non-linearities are measured to be less than 0.5 % combining statistical and systematic uncertainties.Comment: 16 page

    The Simulation of the ATLAS Liquid Argon Calorimetry

    Get PDF
    In ATLAS, all of the electromagnetic calorimetry and part of the hadronic calorimetry is performed by a calorimeter system using liquid argon as the active material, together with various types of absorbers. The liquid argon calorimeter consists of four subsystems: the electromagnetic barrel and endcap accordion calorimeters; the hadronic endcap calorimeters, and the forward calorimeters. A very accurate geometrical description of these calorimeters is used as input to the Geant 4-based ATLAS simulation, and a careful modelling of the signal development is applied in the generation of hits. Certain types of Monte Carlo truth information ("Calibration Hits") may, additionally, be recorded for calorimeter cells as well as for dead material. This note is a comprehensive reference describing the simulation of the four liquid argon calorimeteter components

    Search for Top Squark Pair Production in the Dielectron Channel

    Get PDF
    This report describes the first search for top squark pair production in the channel stop_1 stopbar_1 -> b bbar chargino_1 chargino_1 -> ee+jets+MEt using 74.9 +- 8.9 pb^-1 of data collected using the D0 detector. A 95% confidence level upper limit on sigma*B is presented. The limit is above the theoretical expectation for sigma*B for this process, but does show the sensitivity of the current D0 data set to a particular topology for new physics.Comment: Five pages, including three figures, submitted to PRD Brief Report

    Measurement of the WW Boson Mass

    Full text link
    A measurement of the mass of the WW boson is presented based on a sample of 5982 WeνW \rightarrow e \nu decays observed in ppp\overline{p} collisions at s\sqrt{s} = 1.8~TeV with the D\O\ detector during the 1992--1993 run. From a fit to the transverse mass spectrum, combined with measurements of the ZZ boson mass, the WW boson mass is measured to be MW=80.350±0.140(stat.)±0.165(syst.)±0.160(scale)GeV/c2M_W = 80.350 \pm 0.140 (stat.) \pm 0.165 (syst.) \pm 0.160 (scale) GeV/c^2.Comment: 12 pages, LaTex, style Revtex, including 3 postscript figures (submitted to PRL

    Search for W~1Z~2\widetilde{W}_1\widetilde{Z}_2 Production via Trilepton Final States in ppˉp\bar{p} collisions at s=1.8\sqrt{s}=1.8 TeV

    Full text link
    We have searched for associated production of the lightest chargino, W~1\widetilde{W}_1, and next-to-lightest neutralino, Z~2\widetilde{Z}_2, of the Minimal Supersymmetric Standard Model in ppˉp\bar{p} collisions at \mbox{s\sqrt{s} = 1.8 TeV} using the \D0 detector at the Fermilab Tevatron collider. Data corresponding to an integrated luminosity of 12.5±0.7\pm 0.7 \ipb were examined for events containing three isolated leptons. No evidence for W~1Z~2\widetilde{W}_1\widetilde{Z}_2 pair production was found. Limits on σ(W~1Z~2)\sigma(\widetilde{W}_1\widetilde{Z}_2)Br(W~1lνZ~1)(\widetilde{W}_1\to l\nu\widetilde{Z}_1)Br(Z~2llˉZ~1)(\widetilde{Z}_2\to l\bar{l}\widetilde{Z}_1) are presented.Comment: 17 pages (13 + 1 page table + 3 pages figures). 3 PostScript figures will follow in a UUEncoded, gzip'd, tar file. Text in LaTex format. Submitted to Physical Review Letters. Replace comments - Had to resumbmit version with EPSF directive

    Search for a Fourth Generation Charge -1/3 Quark via Flavor Changing Neutral Current Decay

    Get PDF
    We report on a search for pair production of a fourth generation charge -1/3 quark (b') in pbar p collisions at sqrt(s) = 1.8 TeV at the Fermilab Tevatron using an integrated luminosity of 93 pb^-1. Both quarks are assumed to decay via flavor changing neutral currents (FCNC). The search uses the signatures gamma + 3 jets + mu-tag and 2 gamma + 2 jets. We see no significant excess of events over the expected background. We place an upper limit on the production cross section times branching fraction that is well below theoretical expectations for a b' quark decaying exclusively via FCNC for b' quark masses up to m(Z) + m(b).Comment: Eleven pages, two postscript figures, submitted to Physical Review Letter
    corecore