28,605 research outputs found
Noise-induced dynamical transition in systems with symmetric absorbing states
We investigate the effect of noise strength on the macroscopic ordering
dynamics of systems with symmetric absorbing states. Using an explicit
stochastic microscopic model, we present evidence for a phase transition in the
coarsening dynamics, from an Ising-like to a voter-like behavior, as the noise
strength is increased past a nontrivial critical value. By mapping to a thermal
diffusion process, we argue that the transition arises due to locally-absorbing
states being entered more readily in the high-noise regime, which in turn
prevents surface tension from driving the ordering process.Comment: v2 with improved introduction and figures, to appear in PRL. 4 pages,
4 figure
Suppression of combustion oscillations with mechanical devices Interim report
Static rocket thrust chamber simulator for cylindrical cold flow-type apparatus desig
Estimation of Costs of Phosphorus Removal In Wastewater Treatment Facilities: Adaptation of Existing Facilities
As part of a wider enquiry into the feasibility of offset banking schemes as a means to implement pollutant trading within Georgia watersheds, this is the second of two reports addressing the issue of estimating costs for upgrades in the performance of phosphorus removal in point-source wastewater treatment facilities. Earlier, preliminary results are presented in Jiang et al (2004) (Working Paper # 2004-010 of the Georgia Water Planning and Policy Center). The present study is much more detailed and employs an advanced software package (WEST®, Hemmis nv, Kortrijk, Belgium) for simulating a variety of treatment plant designs operating under typical Georgia conditions. Specifically, upgrades in performance, in a single step, from a plant working at an effluent limit of less than 2.0 mg/l phosphorus to one working with limits variously ranging between less than 1.0 mg/l to less than 0.05 mg/l phosphorus are simulated and the resulting costs of the upgrade estimated.Five capacities of plant are considered, from 1 MGD to 100 MGD. Three strategic, alternative designs for the facility are considered: the basic activated sludge (AS) process with chemical addition, the Anoxic/Oxic (A/O) arrangement of the AS process, and the Anaerobic/Aerobic/Oxic (A/A/O) arrangement of the AS process. Upgrades in performance are consistent with the logical alternatives for adapting these options. Cost comparisons are made primarily on the basis of the incremental cost of the upgrade, i.e., from the base-case, reference plant to that performing at the higher level, as expressed through the incremental Total Annual Economic Cost (TAEC; in /kg).For the most stringent upgrade, for example, to a plant generating an effluent with less than 0.05 mg/l phosphorus, these marginal costs -- the cost of the additional phosphorus removed as a result of the upgrade -- amount to something of the order of 150-425 $/kg, with the upper bound being associated with the smallest plant configuration (1 MGD). Working Paper Number 2005-001
Preliminary Results from Recent Measurements of the Antiprotonic Helium Hyperfine Structure
We report on preliminary results from a systematic study of the hyperfine
(HF) structure of antiprotonic helium. This precise measurement which was
commenced in 2006, has now been completed. Our initial analysis shows no
apparent density or power dependence and therefore the results can be averaged.
The statistical error of the observable M1 transitions is a factor of 60
smaller than that of three body quantum electrodynamic (QED) calculations,
while their difference has been resolved to a precision comparable to theory (a
factor of 10 better than our first measurement). This difference is sensitive
to the antiproton magnetic moment and agreement between theory and experiment
would lead to an increased precision of this parameter, thus providing a test
of CPT invariance.Comment: 6 pages, 4 figure
- …