18 research outputs found

    Will naturally ventilated dwellings remain safe during heatwaves?

    Get PDF
    International audienceHeatwaves are responsible for many deaths due to hot weather. Natural ventilation is promoted as a cooling solution to reduce the impacts of climate change because of its energy-saving potential. This paper addresses the prediction of heat-related health risk situations in naturally ventilated dwellings, where indoor thermal conditions depend on external climate and occupant behaviour. Thus, the operating limits of a dwelling vary according to its dynamic thermal response to indoor and outdoor stresses. To secure a building design, a method to improve the prediction of heat-related health risks is proposed that links predicted percentage dissatisfied (PPD) and wet-bulb globe temperature (WBGT) indicators to distinguish a moderately warm situation from a heat stress situation (WBGT>29°C). Simulations are performed for a dwelling during the 2015 heatwave in Paris (France) to test the method. In the example, natural ventilation was found to reduce the indoor temperature, but there remains ambiguity regarding the ability of natural ventilation to provide moderate conditions. According to the scope of the ergonomic standards, "moderate thermal environment" and "heat stress" temperature ranges are not contiguous. Bridging of this gap requires establishing thermal comfort ranges and heat stress thresholds adapted to people according to their acclimatisation level and their sensitivity to heat

    Applicability and relevance of six indoor air quality indexes

    Get PDF
    International audienceThe evaluation of indoor air quality (IAQ) in buildings is complex because IAQ involves a broad spectrum of substances and agents that vary over time and space. To address this complexity, IAQ indexes are used to describe, classify and improve IAQ by providing easy-to-understand and comprehensive rankings of IAQ levels in buildings. Although many IAQ indexes have been proposed all over the world, their relevancy regarding the evaluation of IAQ levels has not been fully studied in a large number of dwellings. In this study, six measurement-based IAQ indexes proposed for use in the USA, France, Taiwan, and Hong Kong were evaluated. The calculation of IAQ levels was based on nine indoor parameters measured in 567 French dwellings, i.e., indoor air temperature, relative humidity, and concentrations of formaldehyde, total volatile organic compounds, radon, carbon monoxide, carbon dioxide, PM2.5, and PM10. A factorial analysis using the multiple correspondence analysis and the hierarchical cluster analysis methods was performed to determine whether the calculated IAQ levels of different indexes in the studied dwellings were repeatable across all indexes. The results showed that three of the indexes tended to provide only positive IAQ ratings, while the other three indexes were more discriminating. Three classes of IAQ levels in dwellings, along with indoor parameters associated with each class, were identified. All of the indoor parameters were associated with the classification of IAQ 2 levels, while the formaldehyde concentration and relative humidity were the key parameters to identify the dwellings with the best IAQ

    Base de référence nationale sur la qualité de l'air intérieur et le confort des occupants de bâtiments performants en énergie : deuxième état descriptif de la qualité de l'air intérieur et du confort de bâtiments d'habitation performants en énergie

    Get PDF
    Ce travail, réalisé dans le cadre de la convention 2014-2015 du programme "Bâtiments Performants en Énergie" de l'OQAI, fournit un deuxième état descriptif des données de qualité de l'environnement intérieur de bâtiments d'habitation performants en énergie. Il porte sur les données d'enquête relatives à 72 logements répartis dans 43 bâtiments. Le rapport, structuré en trois parties, présente : 1 /les caractéristiques des bâtiments, des logements et de leurs occupants ; 2 /les résultats des mesures de concentration du CO2, des indicateurs de qualité d'air intérieur, des paramètres de confort thermique et des débits/pressions aux bouches des systèmes de ventilation mécanique ainsi que la mise en perspective de ces résultats avec la population nationale de logements et les réglementations en vigueur non spécifiques à l'habitat ; 3/ les résultats d'une étude exploratoire sur l'influence de trois variables d'intérêt liées au bâtiment (pièce de mesure, type d'habitat et catégorie de logement) sur la qualité de l'environnement intérieur. Cette deuxième exploitation des données de la base nationale OQAI-BPE confirme les premières tendances observées lors de la première étude, à savoir une qualité de l'air intérieur globalement comparable dans les logements performants en énergie étudiés par rapport à la population nationale de logements, avec néanmoins quelques différences mises en évidence. Ainsi, dans les logements performants en énergie, on observe un indice de contamination fongique plus élevé en proportion, des concentrations en hexaldéhyde, alpha-pinène et limonène plus élevées, et des températures intérieures plus élevées. La suite de l'exploitation de la base OQAI-BPE vise à l'analyse approfondie des données de mesures en fonction des caractéristiques des bâtiments et de leurs occupants

    Ventilation in French buildings

    No full text
    http://www.aivc.orgInternational audienc

    Ventilation in French buildings

    No full text
    http://www.aivc.orgInternational audienc

    A Methodology for Assembling Future Weather Files Including Heatwaves for Building Thermal Simulations from the European Coordinated Regional Downscaling Experiment (EURO-CORDEX) Climate Data

    No full text
    With increasing mean and extreme temperatures due to climate change, it becomes necessary to use—not only future typical conditions—but future heatwaves in building thermal simulations as well. Future typical weather files are widespread, but few researchers have put together methodologies to reproduce future extreme conditions. Furthermore, climate uncertainties need to be considered and it is often difficult due to the lack of data accessibility. In this article, we propose a methodology to re-assemble future weather files—ready-to-use for building simulations—using data from the European Coordinated Regional Downscaling Experiment (EURO-CORDEX) dynamically downscaled regional climate multi-year projections. It is the first time that this database is used to assemble weather files for building simulations because of its recent availability. Two types of future weather files are produced: typical weather years (TWY) and heatwave events (HWE). Combined together, they can be used to fully assess building resilience to overheating in future climate conditions. A case study building in Paris is modelled to compare the impact of the different weather files on the indoor operative temperature of the building. The results confirm that it is better to use multiple types of future weather files, climate models, and or scenarios to fully grasp climate projection uncertainties

    Exposure Assessment of Allergens and Metals in Settled Dust in French Nursery and Elementary Schools

    No full text
    The aim of this study was to characterise the contamination in settled dust in French classrooms and to provide an overview of the influencing factors of dust contamination. Cat, dog and dust mite allergens and metals were measured in 51 classrooms at 17 schools. The concentrations of pet allergens in settled dust were generally low (mean value of 0.1 µg·g−1), with carpeted and rug-covered floors presenting higher dust and cat allergen concentrations. The highest metal loadings in dust were observed for manganese (Mn) and copper (Cu), while the lead (Pb) loadings were lower (16 ± 19 µg·m−2) and fell below the French guideline. Higher metal leachability was found for cadmium (Cd), Cu, Pb and strontium (Sr) at values of approximately 80%, which suggest that, in cases of dust ingestion by children, a large proportion should be assimilated through the gastro-intestinal tract. The intra-classroom and intra-school variabilities of the metal concentrations in settled dust were lower than the variability between schools. Classrooms with tiled floors had higher Pb loadings than classrooms with wood or vinyl floors. In addition, wet cleaning less than once a week resulted in greater loadings of Cu and Pb in the settled dust. Lastly, enrichment factors showed that metals in settled dust of classrooms were not only from the contribution of the natural background concentrations in soils

    Base de référence nationale sur la qualité de l'air intérieur et le confort des occupants de bâtiments performants en énergie : deuxième état descriptif de la qualité de l'air intérieur et du confort de bâtiments d'habitation performants en énergie

    No full text
    Ce travail, réalisé dans le cadre de la convention 2014-2015 du programme "Bâtiments Performants en Énergie" de l'OQAI, fournit un deuxième état descriptif des données de qualité de l'environnement intérieur de bâtiments d'habitation performants en énergie. Il porte sur les données d'enquête relatives à 72 logements répartis dans 43 bâtiments. Le rapport, structuré en trois parties, présente : 1 /les caractéristiques des bâtiments, des logements et de leurs occupants ; 2 /les résultats des mesures de concentration du CO2, des indicateurs de qualité d'air intérieur, des paramètres de confort thermique et des débits/pressions aux bouches des systèmes de ventilation mécanique ainsi que la mise en perspective de ces résultats avec la population nationale de logements et les réglementations en vigueur non spécifiques à l'habitat ; 3/ les résultats d'une étude exploratoire sur l'influence de trois variables d'intérêt liées au bâtiment (pièce de mesure, type d'habitat et catégorie de logement) sur la qualité de l'environnement intérieur. Cette deuxième exploitation des données de la base nationale OQAI-BPE confirme les premières tendances observées lors de la première étude, à savoir une qualité de l'air intérieur globalement comparable dans les logements performants en énergie étudiés par rapport à la population nationale de logements, avec néanmoins quelques différences mises en évidence. Ainsi, dans les logements performants en énergie, on observe un indice de contamination fongique plus élevé en proportion, des concentrations en hexaldéhyde, alpha-pinène et limonène plus élevées, et des températures intérieures plus élevées. La suite de l'exploitation de la base OQAI-BPE vise à l'analyse approfondie des données de mesures en fonction des caractéristiques des bâtiments et de leurs occupants
    corecore