20 research outputs found
Radiation Awareness for Endovascular Abdominal Aortic Aneurysm Repair in the Hybrid Operating Room: An Instant Operator Risk Chart for Daily Practice
Introduction: While the operator radiation dose rates are correlated to patient radiation dose rates, discrepancies may exist in the effect size of each individual radiation dose predictors. An operator dose rate prediction model was developed, compared with the patient dose rate prediction model, and converted to an instant operator risk chart. Materials and Methods: The radiation dose rates (DRoperator for the operator and DRpatient for the patient) from 12,865 abdomen X-ray acquisitions were selected from 50 unique patients undergoing standard or complex endovascular aortic repair (EVAR) in the hybrid operating room with a fixed C-arm. The radiation dose rates were analyzed using a log-linear multivariable mixed model (with the patient as the random effect) and incorporated varying (patient and C-arm) radiation dose predictors combined with the vascular access site. The operator dose rate models were used to predict the expected radiation exposure duration until an operator may be at risk to reach the 20 mSv year dose limit. The dose rate prediction models were translated into an instant operator radiation risk chart. Results: In the multivariate patient and operator fluoroscopy dose rate models, lower DRoperator than DRpatient effect size was found for radiation protocol (2.06 for patient vs 1.4 for operator changing from low to medium protocol) and C-arm angulation. Comparable effect sizes for both DRoperator and DRpatient were found for body mass index (1.25 for patient and 1.27 for the operator) and irradiated field. A higher effect size for the DRoperator than DRpatient was found for C-arm rotation (1.24 for the patient vs 1.69 for the operator) and exchanging from femoral access site to brachial access (1.05 for patient vs 2.5 for the operator). Operators may reach their yearly 20 mSv year dose limit after 941 minutes from the femoral access vs 358 minutes of digital subtraction angiography radiation from the brachial access. Conclusion: The operator dose rates were correlated to patient dose rate; however, C-arm angulation and changing from femoral to brachial vascular access site may disproportionally increase the operator radiation risk compared with the patient radiation risk. An instant risk chart may improve operator dose awareness during EVAR
Исследование характеристик щелевого теплообменника с развитой поверхностью теплообмена
Предложена конструкция водяного многоканального щелевого теплообменника, позволяющего отводить мощность до 750 Вт при температуре имитатора теплового потока 60°С, а также пути повышения технологичности изготовления теплообменника
ENDOVASCULAR ANEURYSM REPAIR IN WIDE INFRARENAL NECKS - INCREASED RISK OF COMPLICATIONS?
EVAR has become the predominant repair technique for abdominal aortic aneurysm. Long-term clinical success relies greatly upon a long-lasting proximal seal. EVAR has achieved good outcomes on the short-term in patients with hostile neck features such as large proximal necks. However, the long-term outcomes in these patients is greatly unknown. In this article, the authors perform a literature review in order to assess the clinical impact of wide proximal neck on mid to long-term outcomes following EVAR
Current state in tracking and robotic navigation systems for application in endovascular aortic aneurysm repair
Objective This study reviewed the current developments in manual tracking and robotic navigation technologies for application in endovascular aortic aneurysm repair (EVAR). Methods EMBASE and MEDLINE databases were searched for studies reporting manual tracking or robotic navigation systems that are able to manipulate endovascular surgical tools during abdominal or thoracic aortic aneurysm repair. Reports were grouped by the navigation systems and categorized into phantom, animal, and clinical studies. First, the general characteristics of each system were compared. Second, target registration error and deployment error were used to compare the accuracy of the tracking systems. Third, all systems were reviewed for fluoroscopy time (FT), radiation dose, and contrast volumes, if reported, in rigid and nonrigid studies. Fourth, vascular cannulation performance of the systems was compared, studying cannulation time, Imperial College Complex Cannulation Scoring Tool score, and the number of wall hits and catheter movements within rigid studies. Results Of 721 articles and references found, 18 studies of four different navigation systems were included: the Aurora (Northern Digital, Waterloo, Ontario, Canada) tracking system, the StealthStation (Medtronic Inc, Minneapolis, Minn) tracking system, an ultrasound localization tracking system, and the Sensei (Hansen Medical, Mountain View, Calif) steerable remote-controlled robotic navigation system. The mean tracking accuracy averaged 1 mm for the three manual tracking systems measured in a rigid environment. An increase of target registration error reaching >3 mm was reported when measured in a nonrigid experimental environment or due to external distortion factors. Except within small-animal studies or case studies, no evidence was found on reduction of clinical outcome parameters, such as FT, radiation dose, and contrast volumes, within clinical EVAR. A comparison of vascular cannulation performance in rigid studies revealed that the Sensei robotic system might have an advantage during advanced cannulation compared with standard cannulation within complex cannulations tasks. Conclusions This review summarizes the current studies on manual tracking and robotic navigation systems for application in EVAR. The main focus of these systems is improving aortic vessel cannulation, required in complex EVAR, in which the robotic system with the improved steerability is favored over manual tracking systems or conventional cannulation. All reviewed tracking systems still require X-ray for anatomic imaging, stent graft deployment, and device registration. Although the current reviewed endovascular navigation systems have shown their potential in phantom and animal studies, clinical trials are too limited to conclude that these systems can improve EVAR outcomes or that they can systematically reduce FTs, radiation doses, and contrast volumes during (complex) EVAR
Allura clarity radiation dose-reduction technology in the hybrid operating room during endovascular aneurysm repair
Purpose: To evaluate the effect of radiation dose reduction with the Allura ClarityIQ image processing technology for fixed C-arms in comparison with a mobile C-arm and an Allura fixed C-arm without ClarityIQ technology during endovascular aneurysm repair (EVAR) procedures. Methods: Radiation dose data from 85 patients (mean age 74.2±7.8 years; 68 men) undergoing EVAR with mobile and fixed C-arm fluoroscopy were retrospectively analyzed. The radiation dose parameters included the kerma area product (KAP), fluoroscopic time (FT), and number of digital subtraction angiography (DSA) frames (FrDSA). KAPtotal consisted of KAPfluoro (KAP for fluoroscopic imaging) and KAPDSA (KAP for DSA and single shots). Linear regression analysis was used to explore differences in the association of KAP with the FT, FrDSA, and body mass index (BMI) among the 3 C-arms. Results: The mean KAPtotal values for mobile, Allura C-arm, and AlluraClarity C-arm for noncomplex EVARs were 56±39, 245±142, and 157±120 Gycm2 (p2 (pfluoro tripled when the mobile C-arm was replaced by the fixed C-arm. There were no significant differences in the KAPfluoro adjusted for the FT between Allura and AlluraClarity (p=0.69). However, there was a major 61% reduction in KAPDSA from 1.36 Gycm2 per DSA frame for Allura to 0.54 Gycm2 per DSA frame with AlluraClarity (p=0.03). For the mobile C-arm, BMI was not associated with KAP (p=0.13). The associations of BMI with KAPfluoro and KAPDSA were significant for both fixed C-arms but were more robust for Allura compared to AlluraClarity (p=0.02 for KAPfluoro and pDSA). Conclusion: Changing a mobile C-arm for a fixed C-arm in a hybrid operating suite increased the average intraoperative dose during EVAR. Upgrading the Allura fixed C-arm with ClarityIQ technology resulted in a 61% reduction in the radiation per DSA frame
Meta-analysis of Cumulative Radiation Duration and Dose During EVAR Using Mobile, Fixed, or Fixed/3D Fusion C-Arms
PURPOSE: To investigate the total fluoroscopy time and radiation exposure dose during endovascular aortic repairs using mobile, fixed, or fixed C-arms with 3-dimensional image fusion (3D-IF). METHODS: A systematic search was performed to identify original articles reporting fluoroscopy time (FT) and the kerma area product (KAP) during endovascular aortic repairs. Data were grouped by noncomplex or complex (fenestrated, branched, or chimney) repairs and stratified by type of C-arm. The search identified 27 articles containing 51 study groups (35 noncomplex and 16 complex) that included 3444 patients. Random-effects meta-analysis and meta-regression models were used to calculate the pooled mean estimates of KAP and FT, as well as any effect of equipment or type of intervention. Results are presented with the 95% confidence interval and the statistical heterogeneity (I(2)). RESULTS: Within the noncomplex procedure studies, a significant (p<0.001) increase was found in the pooled mean KAP estimate in the fixed C-arm group (181 Gy·cm(2), 95% CI 129 to 233; I(2)=99.7) compared with the mobile C-arm (78 Gy·cm(2), 95% CI 59.6 to 97.3; I(2)=99.6). For complex cases, use of 3D-IF showed a significantly (p<0.001) lower mean KAP (139 Gy·cm(2), 95% CI 85 to 191; I(2)=94%) compared to using fixed C-arms without 3D-IF (487 Gy·cm(2), 95% CI 331 to 643; I(2)=94%). CONCLUSION: For equivalent fluoroscopy times, the use of a fixed C-arm in noncomplex procedures leads to higher patient radiation doses compared to a mobile C-arm. Complex procedures, which are predominantly performed using fixed C-arms, are associated with the highest radiation dose per intervention. Using fixed C-arms combined with 3D-IF techniques during complex cases might seem an adequate method to compensate for the higher radiation doses measured when a fixed C-arm is used