17 research outputs found

    Rhodium-Catalyzed Enantioselective Hydrogenation of Oxime Acetates

    No full text
    Rh-catalyzed enantioselective hydrogenation of oxime acetates was first reported, which afforded a new approach for chiral amine synthesis

    Direct Catalytic Asymmetric Reductive Amination of Simple Aromatic Ketones

    No full text
    A green method for chiral amine synthesis, the direct catalytic asymmetric reductive amination, was developed. Phenylhydrazide is an ideal nitrogen source for reductive amination. Molecular sieves play dual roles in this reaction. They help to remove H<sub>2</sub>O to form imine, as well as promote an imine reduction. f-Binaphane minimizes the inhibition effect from amines and helps the coordination of sterically demanding imines to the iridium center, thus leading to a smooth reaction

    Transition-Metal-Catalyzed Asymmetric Reductive Amination and Amidation Cascade Reaction for the Synthesis of Piperazinones

    No full text
    An efficient enantioselective reductive amination and amidation cascade reaction has been developed. Catalyzed by iridium or rhodium complexes and with the help of sets of additives, the coupling of simple alkyl diamines and α-ketoesters occurs smoothly to afford the chiral cyclic piperazinone products. For disubstituted and monosubstituted alkyl diamine substrates, the corresponding reactions proceed through distinctive types of intermediates and thus require different transition metals to achieve high enantioselectivity, namely, iridium for the former and rhodium for the latter. In this transformation, the applied highly modular phosphoramidite–phosphine hybrid ligands displayed preeminent versatility and tunability

    Forest plot of clinical success rates.

    No full text
    This systematic review and meta-analysis aimed to assess and compare the therapeutic outcomes of cutting balloon angioplasty and high-pressure balloon angioplasty for arteriovenous fistula stenosis in hemodialysis patients. All studies indexed in PubMed, Embase, and Cochrane Library Web of Science were retrieved. The retrieval deadline was July 15, 2023. Risk of bias 2.0 was used to evaluate the quality of the included studies. Revman 5.4 software was used for data analysis. This review included three studies and 180 patients, with 90 patients in the cutting balloon angioplasty group and 90 patients in the high-pressure balloon angioplasty group. The results of the meta-analysis suggested that compared with high-pressure balloon angioplasty, cutting balloon angioplasty can improve primary lesion patency rates of internal arteriovenous fistulas at 6 months (relative risk, 1.45; 95% confidence interval, 1.08–1.96; P = 0.01). However, there were no significant differences between the technical success rate (relative risk, 0.99; 95% confidence interval, 0.93–1.05; P = 0.72) and clinical success rate (relative risk, 1.01; 95% confidence interval, 0.95–1.07; P = 0.73). Therefore, cutting balloon angioplasty is likely to increase primary lesion patency rates at 6 months. However, more high-quality, large-sample, multicenter, randomized controlled trials are needed for further validation due to the limited number of included studies.</div

    Grade profiler.

    No full text
    This systematic review and meta-analysis aimed to assess and compare the therapeutic outcomes of cutting balloon angioplasty and high-pressure balloon angioplasty for arteriovenous fistula stenosis in hemodialysis patients. All studies indexed in PubMed, Embase, and Cochrane Library Web of Science were retrieved. The retrieval deadline was July 15, 2023. Risk of bias 2.0 was used to evaluate the quality of the included studies. Revman 5.4 software was used for data analysis. This review included three studies and 180 patients, with 90 patients in the cutting balloon angioplasty group and 90 patients in the high-pressure balloon angioplasty group. The results of the meta-analysis suggested that compared with high-pressure balloon angioplasty, cutting balloon angioplasty can improve primary lesion patency rates of internal arteriovenous fistulas at 6 months (relative risk, 1.45; 95% confidence interval, 1.08–1.96; P = 0.01). However, there were no significant differences between the technical success rate (relative risk, 0.99; 95% confidence interval, 0.93–1.05; P = 0.72) and clinical success rate (relative risk, 1.01; 95% confidence interval, 0.95–1.07; P = 0.73). Therefore, cutting balloon angioplasty is likely to increase primary lesion patency rates at 6 months. However, more high-quality, large-sample, multicenter, randomized controlled trials are needed for further validation due to the limited number of included studies.</div

    S1 Data -

    No full text
    This systematic review and meta-analysis aimed to assess and compare the therapeutic outcomes of cutting balloon angioplasty and high-pressure balloon angioplasty for arteriovenous fistula stenosis in hemodialysis patients. All studies indexed in PubMed, Embase, and Cochrane Library Web of Science were retrieved. The retrieval deadline was July 15, 2023. Risk of bias 2.0 was used to evaluate the quality of the included studies. Revman 5.4 software was used for data analysis. This review included three studies and 180 patients, with 90 patients in the cutting balloon angioplasty group and 90 patients in the high-pressure balloon angioplasty group. The results of the meta-analysis suggested that compared with high-pressure balloon angioplasty, cutting balloon angioplasty can improve primary lesion patency rates of internal arteriovenous fistulas at 6 months (relative risk, 1.45; 95% confidence interval, 1.08–1.96; P = 0.01). However, there were no significant differences between the technical success rate (relative risk, 0.99; 95% confidence interval, 0.93–1.05; P = 0.72) and clinical success rate (relative risk, 1.01; 95% confidence interval, 0.95–1.07; P = 0.73). Therefore, cutting balloon angioplasty is likely to increase primary lesion patency rates at 6 months. However, more high-quality, large-sample, multicenter, randomized controlled trials are needed for further validation due to the limited number of included studies.</div

    Characteristics of the included studies.

    No full text
    This systematic review and meta-analysis aimed to assess and compare the therapeutic outcomes of cutting balloon angioplasty and high-pressure balloon angioplasty for arteriovenous fistula stenosis in hemodialysis patients. All studies indexed in PubMed, Embase, and Cochrane Library Web of Science were retrieved. The retrieval deadline was July 15, 2023. Risk of bias 2.0 was used to evaluate the quality of the included studies. Revman 5.4 software was used for data analysis. This review included three studies and 180 patients, with 90 patients in the cutting balloon angioplasty group and 90 patients in the high-pressure balloon angioplasty group. The results of the meta-analysis suggested that compared with high-pressure balloon angioplasty, cutting balloon angioplasty can improve primary lesion patency rates of internal arteriovenous fistulas at 6 months (relative risk, 1.45; 95% confidence interval, 1.08–1.96; P = 0.01). However, there were no significant differences between the technical success rate (relative risk, 0.99; 95% confidence interval, 0.93–1.05; P = 0.72) and clinical success rate (relative risk, 1.01; 95% confidence interval, 0.95–1.07; P = 0.73). Therefore, cutting balloon angioplasty is likely to increase primary lesion patency rates at 6 months. However, more high-quality, large-sample, multicenter, randomized controlled trials are needed for further validation due to the limited number of included studies.</div

    Risk of bias.

    No full text
    This systematic review and meta-analysis aimed to assess and compare the therapeutic outcomes of cutting balloon angioplasty and high-pressure balloon angioplasty for arteriovenous fistula stenosis in hemodialysis patients. All studies indexed in PubMed, Embase, and Cochrane Library Web of Science were retrieved. The retrieval deadline was July 15, 2023. Risk of bias 2.0 was used to evaluate the quality of the included studies. Revman 5.4 software was used for data analysis. This review included three studies and 180 patients, with 90 patients in the cutting balloon angioplasty group and 90 patients in the high-pressure balloon angioplasty group. The results of the meta-analysis suggested that compared with high-pressure balloon angioplasty, cutting balloon angioplasty can improve primary lesion patency rates of internal arteriovenous fistulas at 6 months (relative risk, 1.45; 95% confidence interval, 1.08–1.96; P = 0.01). However, there were no significant differences between the technical success rate (relative risk, 0.99; 95% confidence interval, 0.93–1.05; P = 0.72) and clinical success rate (relative risk, 1.01; 95% confidence interval, 0.95–1.07; P = 0.73). Therefore, cutting balloon angioplasty is likely to increase primary lesion patency rates at 6 months. However, more high-quality, large-sample, multicenter, randomized controlled trials are needed for further validation due to the limited number of included studies.</div
    corecore