918 research outputs found

    A review on the discovery reach of Dark Matter directional detection

    Full text link
    Directional detection of galactic Dark Matter offers a unique opportunity to identify Weakly Interacting Massive Particle (WIMP) events as such. Depending on the unknown WIMP-nucleon cross section, directional detection may be used to : exclude Dark Matter, discover galactic Dark Matter with a high significance or constrain WIMP and halo properties. We review the discovery reach of Dark Matter directional detection.Comment: Proceedings of the 4th international conference on Directional Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japa

    Identification of Dark Matter with directional detection

    Full text link
    Directional detection is a promising search strategy to discover galactic Dark Matter. Taking advantage on the rotation of the Solar system around the Galactic center through the Dark Matter halo, it allows to show a direction dependence of WIMP events. Data of directional detectors are composed of energy and a 3D track for each recoiling nuclei. Here, we present a Bayesian analysis method dedicated to data from upcoming directional detectors. However, we focus only on the angular part of the event distribution, arguing that the energy part of the background distribution is unknown. Two different cases are considered: a positive or a null detection of Dark Matter. In the first scenario, we will present a map-based likelihood method allowing to recover the main incoming direction of the signal and its significance, thus proving its Galactic origin. In the second scenario, a new statistical method is proposed. It is based on an extended likelihood in order to set robust and competitive exclusion limits. This method has been compared to two other methods and has been shown to be optimal in any detector configurations. Eventually, prospects for the MIMAC project are presented in the case of a 10 kg CF4 detector with an exposition time of 3 years.Comment: Proceeding of the 8th International Workshop on the Identification of Dark Matter (IDM 2010), July 2010, Montpellier, France. To appear in Proceedings of Science (PoS

    Directional detection of galactic dark matter

    Full text link
    Directional detection is a promising Dark Matter search strategy. Taking advantage on the rotation of the Solar system around the galactic center through the Dark Matter halo, it allows to show a direction dependence of WIMP events that may be a powerful tool to identify genuine WIMP events as such. Directional detection strategy requires the simultaneous measurement of the energy and the 3D track of low energy recoils, which is a common challenge for all current projects of directional detectors.Comment: Proceedings of UCLA Dark Matter 2012, 10th Symposium on Sources and Detection of Dark Matter and Dark Energy in the Universe, Marina del Rey Marriott, CA, USA, February 22-24, 201

    An analysis method for time ordered data processing of Dark Matter experiments

    Full text link
    The analysis of the time ordered data of Dark Matter experiments is becoming more and more challenging with the increase of sensitivity in the ongoing and forthcoming projects. Combined with the well-known level of background events, this leads to a rather high level of pile-up in the data. Ionization, scintillation as well as bolometric signals present common features in their acquisition timeline: low frequency baselines, random gaussian noise, parasitic noise and signal characterized by well-defined peaks. In particular, in the case of long-lasting signals such as bolometric ones, the pile-up of events may lead to an inaccurate reconstruction of the physical signal (misidentification as well as fake events). We present a general method to detect and extract signals in noisy data with a high pile-up rate and qe show that events from few keV to hundreds of keV can be reconstructed in time ordered data presenting a high pile-up rate. This method is based on an iterative detection and fitting procedure combined with prior wavelet-based denoising of the data and baseline subtraction. {We have tested this method on simulated data of the MACHe3 prototype experiment and shown that the iterative fitting procedure allows us to recover the lowest energy events, of the order of a few keV, in the presence of background signals from a few to hundreds of keV. Finally we applied this method to the recent MACHe3 data to successfully measure the spectrum of conversion electrons from Co57 source and also the spectrum of the background cosmic muons

    Directional Detection of Dark Matter with MIMAC

    Full text link
    Directional detection is a promising search strategy to discover galactic Dark Matter. We present a Bayesian analysis framework dedicated to Dark Matter phenomenology using directional detection. The interest of directional detection as a powerful tool to set exclusion limits, to authentify a Dark Matter detection or to constrain the Dark Matter properties, both from particle physics and galactic halo physics, will be demonstrated. However, such results need highly accurate track reconstruction which should be reachable by the MIMAC detector using a dedicated readout combined with a likelihood analysis of recoiling nuclei.Comment: 4 pages, 2 figures, to appear in the proceedings of the TAUP 2011 conference held in Munich (5 - 9 September, 2011

    MIMAC-He3 : A Micro-TPC Matrix of Chambers of He3 for direct detection of Wimps

    Full text link
    The project of a micro-TPC matrix of chambers of \hetrois for direct detection of non-baryonic dark matter is presented. The privileged properties of He3 are highlighted. The double detection (ionization - projection of tracks) is explained and its rejection evaluated. The potentialities of MIMAC-He3 for supersymmetric dark matter search are discussed.Comment: to appear in Proc. of the 9th International Conference on Topics in Astroparticle and Underground Physics (TAUP 2005), Zaragoza, Sept. 200

    GePEToS : A Geant4 Monte Carlo simulation package for Positron Emission Tomography

    Full text link
    GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object-Oriented C++ and runs on Linux platforms. The validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+ camera. The results of two application examples are presented : the design optimization of a liquid Xe micro-PET camera dedicated to small animal imaging as well as the evaluation of the effect of a strong axial magnetic field on the image resolution of a Concorde P4 micro-PET camera.Comment: 5 pages, 12 figures, submitted to IEEE Transactions on Nuclear Scienc

    Track reconstruction with MIMAC

    Full text link
    Directional detection of Dark Matter is a promising search strategy. However, to perform such kind of detection, the recoiling tracks have to be accurately reconstructed: direction, sense and position in the detector volume. In order to optimize the track reconstruction and to fully exploit the data from the MIMAC detector, we developed a likelihood method dedicated to the track reconstruction. This likelihood approach requires a full simulation of track measurements with MIMAC in order to compare real tracks to simulated ones. Finally, we found that the MIMAC detector should have the required performance to perform a competitive directional detection of Dark Matter.Comment: 9 pages, 6 figures; Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 201

    Bolometric calibration of a superfluid 3^3He detector for Dark Matter search: direct measurement of the scintillated energy fraction for neutron, electron and muon events

    Full text link
    We report on the calibration of a superfluid 3^3He bolometer developed for the search of non-baryonic Dark Matter. Precise thermometry is achieved by the direct measurement of thermal excitations using Vibrating Wire Resonators (VWRs). The heating pulses for calibration were produced by the direct quantum process of quasiparticle generation by other VWRs present. The bolometric calibration factor is analyzed as a function of temperature and excitation level of the sensing VWR. The calibration is compared to bolometric measurements of the nuclear neutron capture reaction and heat depositions by cosmic muons and low energy electrons. The comparison allows a quantitative estimation of the ultra-violet scintillation rate of irradiated helium, demonstrating the possibility of efficient electron recoil event rejection.Comment: 17 pages, submitted to Nuc. Instr. Meth.
    • …
    corecore