928 research outputs found
Vibration control of flexible structures using fusion of inertial sensors and hyper-stable actuator-sensor pairs
This paper discusses sensor fusion techniques that can be used to increase the control bandwidth and stability
of active vibration isolation systems. For this, a low noise inertial instrument dominates the fusion at low
frequency to provide vibration isolation. Other types of sensors (relative motion, smaller but noisier inertial,
or force sensors) are used at higher frequencies to increase stability. Several sensor fusion configurations are
studied. The paper shows the improvement that can be expected for several case studies
Seismic isolation of Advanced LIGO: Review of strategy, instrumentation and performance
The new generation of gravitational waves detectors require unprecedented levels of isolation from seismic noise. This article reviews the seismic isolation strategy and instrumentation developed for the Advanced LIGO observatories. It summarizes over a decade of research on active inertial isolation and shows the performance recently achieved at the Advanced LIGO observatories. The paper emphasizes the scientific and technical challenges of this endeavor and how they have been addressed. An overview of the isolation strategy is given. It combines multiple layers of passive and active inertial isolation to provide suitable rejection of seismic noise at all frequencies. A detailed presentation of the three active platforms that have been developed is given. They are the hydraulic pre-isolator, the single-stage internal isolator and the two-stage internal isolator. The architecture, instrumentation, control scheme and isolation results are presented for each of the three systems. Results show that the seismic isolation sub-system meets Advanced LIGO's stringent requirements and robustly supports the operation of the two detectors
Frequency-Dependent Squeezing for Advanced LIGO
The first detection of gravitational waves by the Laser Interferometer
Gravitational-wave Observatory (LIGO) in 2015 launched the era of gravitational
wave astronomy. The quest for gravitational wave signals from objects that are
fainter or farther away impels technological advances to realize ever more
sensitive detectors. Since 2019, one advanced technique, the injection of
squeezed states of light is being used to improve the shot noise limit to the
sensitivity of the Advanced LIGO detectors, at frequencies above Hz.
Below this frequency, quantum back action, in the form of radiation pressure
induced motion of the mirrors, degrades the sensitivity. To simultaneously
reduce shot noise at high frequencies and quantum radiation pressure noise at
low frequencies requires a quantum noise filter cavity with low optical losses
to rotate the squeezed quadrature as a function of frequency. We report on the
observation of frequency-dependent squeezed quadrature rotation with rotation
frequency of 30Hz, using a 16m long filter cavity. A novel control scheme is
developed for this frequency-dependent squeezed vacuum source, and the results
presented here demonstrate that a low-loss filter cavity can achieve the
squeezed quadrature rotation necessary for the next planned upgrade to Advanced
LIGO, known as "A+."Comment: 6 pages, 2 figures, to be published in Phys. Rev. Let
Advanced LIGO two-stage twelve-axis vibration isolation and positioning platform. Part 2: Experimental investigation and tests results
This paper presents the results of the past seven years of experimental investigation and testing done on the two-stage twelve-axis vibration isolation platform for Advanced LIGO gravity waves observatories. This five-ton two-and-half-meter wide system supports more than a 1000 kg of very sensitive equipment. It provides positioning capability and seismic isolation in all directions of translation and rotation. To meet the very stringent requirements of Advanced LIGO, the system must provide more than three orders of magnitude of isolation over a very large bandwidth. It must bring the motion below 10^(−11) m/√Hz at 1 Hz and 10^(−12) m/√Hz at 10 Hz. A prototype of this system has been built in 2006. It has been extensively tested and analyzed during the following two years. This paper shows how the experimental results obtained with the prototype were used to engineer the final design. It highlights how the engineering solutions implemented not only improved the isolation performance but also greatly simplified the assembly, testing, and commissioning process. During the past two years, five units have been constructed, tested, installed and commissioned at each of the two LIGO observatories. Five other units are being built for an upcoming third observatory. The test results presented show that the system meets the motion requirements, and reach the sensor noise in the control bandwidth
Advanced technologies for future ground-based, laser-interferometric gravitational wave detectors
We present a review of modern optical techniques being used and developed for the field of gravitational wave detection. We describe the current state-of-the-art of gravitational waves detector technologies with regard to optical layouts, suspensions and test masses. We discuss the dominant sources and noise in each of these subsystems and the developments that will help mitigate them for future generations of detectors. We very briefly summarise some of the novel astrophysics that will be possible with these upgraded detectors
Ultra-low phase noise squeezed vacuum source for gravitational wave detectors
Squeezed states of light are a valuable resource for reducing quantum noise in precision measurements. Injection of squeezed vacuum states has emerged as an important technique for reducing quantum shot noise, which is a fundamental limitation to the sensitivity of interferometric gravitational wave detectors. Realizing the most benefit from squeezed-state injection requires lowering optical losses and also minimizing squeezed quadrature fluctuations—or phase noise—to ensure that the large noise in the anti-squeezed quadrature does not contaminate the measurement quadrature. Here, we present an audio band squeezed vacuum source with 1.3+0.7−0.5 mrad of phase noise. This is a nearly tenfold improvement over previously reported measurements, improving prospects for squeezing enhancements in current and future gravitational wave detectors
Enhancing the dynamic range of deformable mirrors with compression bias
We report the design and testing of a compression-biased thermally-actuated deformable mirror that has a dynamic range larger than the limit imposed by pure-bending stress, negligible higher-order-mode scattering, and a linear defocus response and that is vacuum compatible. The optimum design principles for this class of actuator are described and a mirror with 370 mD dynamic range is demonstrated.Huy Tuong Cao, Sebastian W. S. Ng, Minkyun Noh, Aidan Brooks, Fabrice Matichard and Peter J. Veitc
- …