29 research outputs found
Short-term efficacy and safety of second generation bipolar transurethral vaporization of the prostate (B-TUVP) for large benign prostate enlargement: Results from a retrospective feasibility study
BackgroundTo investigate the efficacy and safety of a second-generation bipolar transurethral electro vaporization of the prostate (B-TUVP) with the new oval-shaped electrode for large benign prostatic enlargement (BPE) with prostate volume (PV) ≥100ml.Materials and methods100 patients who underwent second-generation B-TUVP with the oval-shaped electrode for male lower urinary tract symptom (LUTS) or urinary retention between July 2018 and July 2020 were enrolled in this study. The patients’ characteristics and treatment outcome were retrospectively compared between patients with PV <100ml and ≥100ml.Results17/41 (41.5%) cases of PV ≥100ml and 24/59 cases (40.7%) of PV <100ml were catheterised due to urinary retention. The duration of post-operative catheter placement and hospital-stay of PV ≥100ml (3.1±1.3 and 5.6±2.3 days) were not different from PV <100ml (2.7±1.2 and 5.0±2.4 days). In uncatheterised patients (N = 59), post-void residual urine volume (PVR) significantly decreased after surgery in both groups, however, maximum uroflow rate (Qmax) significantly increased after surgery only in PV <100ml but not in PV ≥100ml. Voiding symptoms and patients’ QoL derived from International Prostate Symptom Score (IPSS), IPSS-QoL (IPSS Quality of Life Index) and BPH Impact Index (BII) scores, significantly improved after B-TUVP in both groups. Catheter free status after final B-TUVP among patients with preoperative urinary retention was achieved in 18/24 (75.0%) and 14/17 (82.1%) cases in patient with <100ml and ≥100ml, respectively. There was no significant difference in post-operative Hb after B-TUVP, which was 97.0±5.4% of baseline for PV <100ml and 96.9±6.1% for PV ≥100ml and no TUR syndrome was observed.ConclusionsThis is the first study investigating short-term efficacy and safety of second-generation B-TUVP with the oval-shaped electrode on large BPE. B-TUVP appears to be effective and safe for treating moderate-to-severe lower urinary tract symptoms and urinary retention in patients with large BPE
The whole blood transcriptional regulation landscape in 465 COVID-19 infected samples from Japan COVID-19 Task Force
「コロナ制圧タスクフォース」COVID-19患者由来の血液細胞における遺伝子発現の網羅的解析 --重症度に応じた遺伝子発現の変化には、ヒトゲノム配列の個人差が影響する--. 京都大学プレスリリース. 2022-08-23.Coronavirus disease 2019 (COVID-19) is a recently-emerged infectious disease that has caused millions of deaths, where comprehensive understanding of disease mechanisms is still unestablished. In particular, studies of gene expression dynamics and regulation landscape in COVID-19 infected individuals are limited. Here, we report on a thorough analysis of whole blood RNA-seq data from 465 genotyped samples from the Japan COVID-19 Task Force, including 359 severe and 106 non-severe COVID-19 cases. We discover 1169 putative causal expression quantitative trait loci (eQTLs) including 34 possible colocalizations with biobank fine-mapping results of hematopoietic traits in a Japanese population, 1549 putative causal splice QTLs (sQTLs; e.g. two independent sQTLs at TOR1AIP1), as well as biologically interpretable trans-eQTL examples (e.g., REST and STING1), all fine-mapped at single variant resolution. We perform differential gene expression analysis to elucidate 198 genes with increased expression in severe COVID-19 cases and enriched for innate immune-related functions. Finally, we evaluate the limited but non-zero effect of COVID-19 phenotype on eQTL discovery, and highlight the presence of COVID-19 severity-interaction eQTLs (ieQTLs; e.g., CLEC4C and MYBL2). Our study provides a comprehensive catalog of whole blood regulatory variants in Japanese, as well as a reference for transcriptional landscapes in response to COVID-19 infection
DOCK2 is involved in the host genetics and biology of severe COVID-19
「コロナ制圧タスクフォース」COVID-19疾患感受性遺伝子DOCK2の重症化機序を解明 --アジア最大のバイオレポジトリーでCOVID-19の治療標的を発見--. 京都大学プレスリリース. 2022-08-10.Identifying the host genetic factors underlying severe COVID-19 is an emerging challenge. Here we conducted a genome-wide association study (GWAS) involving 2, 393 cases of COVID-19 in a cohort of Japanese individuals collected during the initial waves of the pandemic, with 3, 289 unaffected controls. We identified a variant on chromosome 5 at 5q35 (rs60200309-A), close to the dedicator of cytokinesis 2 gene (DOCK2), which was associated with severe COVID-19 in patients less than 65 years of age. This risk allele was prevalent in East Asian individuals but rare in Europeans, highlighting the value of genome-wide association studies in non-European populations. RNA-sequencing analysis of 473 bulk peripheral blood samples identified decreased expression of DOCK2 associated with the risk allele in these younger patients. DOCK2 expression was suppressed in patients with severe cases of COVID-19. Single-cell RNA-sequencing analysis (n = 61 individuals) identified cell-type-specific downregulation of DOCK2 and a COVID-19-specific decreasing effect of the risk allele on DOCK2 expression in non-classical monocytes. Immunohistochemistry of lung specimens from patients with severe COVID-19 pneumonia showed suppressed DOCK2 expression. Moreover, inhibition of DOCK2 function with CPYPP increased the severity of pneumonia in a Syrian hamster model of SARS-CoV-2 infection, characterized by weight loss, lung oedema, enhanced viral loads, impaired macrophage recruitment and dysregulated type I interferon responses. We conclude that DOCK2 has an important role in the host immune response to SARS-CoV-2 infection and the development of severe COVID-19, and could be further explored as a potential biomarker and/or therapeutic target
A Case of Tumor Lysis Syndrome Induced by Epidermal Growth Factor Receptor Tyrosine Kinase Inhibitor for Lung Adenocarcinoma
Short-term efficacy and safety of second generation bipolar transurethral vaporization of the prostate (B-TUVP) for large benign prostate enlargement: Results from a retrospective feasibility study
Background
To investigate the efficacy and safety of a second-generation bipolar transurethral electro vaporization of the prostate (B-TUVP) with the new oval-shaped electrode for large benign prostatic enlargement (BPE) with prostate volume (PV) ≥100ml.
Materials and methods
100 patients who underwent second-generation B-TUVP with the oval-shaped electrode for male lower urinary tract symptom (LUTS) or urinary retention between July 2018 and July 2020 were enrolled in this study. The patients’ characteristics and treatment outcome were retrospectively compared between patients with PV <100ml and ≥100ml.
Results
17/41 (41.5%) cases of PV ≥100ml and 24/59 cases (40.7%) of PV <100ml were catheterised due to urinary retention. The duration of post-operative catheter placement and hospital-stay of PV ≥100ml (3.1±1.3 and 5.6±2.3 days) were not different from PV <100ml (2.7±1.2 and 5.0±2.4 days). In uncatheterised patients (N = 59), post-void residual urine volume (PVR) significantly decreased after surgery in both groups, however, maximum uroflow rate (Qmax) significantly increased after surgery only in PV <100ml but not in PV ≥100ml. Voiding symptoms and patients’ QoL derived from International Prostate Symptom Score (IPSS), IPSS-QoL (IPSS Quality of Life Index) and BPH Impact Index (BII) scores, significantly improved after B-TUVP in both groups. Catheter free status after final B-TUVP among patients with preoperative urinary retention was achieved in 18/24 (75.0%) and 14/17 (82.1%) cases in patient with <100ml and ≥100ml, respectively. There was no significant difference in post-operative Hb after B-TUVP, which was 97.0±5.4% of baseline for PV <100ml and 96.9±6.1% for PV ≥100ml and no TUR syndrome was observed.
Conclusions
This is the first study investigating short-term efficacy and safety of second-generation B-TUVP with the oval-shaped electrode on large BPE. B-TUVP appears to be effective and safe for treating moderate-to-severe lower urinary tract symptoms and urinary retention in patients with large BPE.
</jats:sec
Post-operative complications following B-TUVP.
Post-operative complications following B-TUVP.</p
Fig 2 -
After careful observation of the enlarged prostate (A), the vaporization procedure started with the creation of a working space at 5 (B) and 7 o’clock (C). Following vaporization of the middle (D), and lateral lobes, well-opened prostate and bladder neck were confirmed (E). The coagulation setting could rapidly be deployed with the same electrode, and even arterial bleeding (F) could be terminated immediately (G, coagulation with oval-shaped electrode, H, confirmation of cessation of bleeding).</p
Fig 1 -
Image of the second-generation B-TUVP with oval electrode (A, Olympus, Tokyo) and zoomed image of the oval electrode (B) (Both images were kindly provided with request for citation by Olympus, Tokyo).Image of vaporization of prostate with the oval electrode in second-generation B-TUVP (C).</p
