2 research outputs found

    Report of an interlaboratory comparison organised by the EU Reference Laboratory for Food Contact Materials - ILC01 2009 - DIDP in Oil Laboratory performance and precision criteria of a harmonised method

    Get PDF
    The Institute for Health and Consumer Protection (IHCP) of the European Commission¿s Directorate-General Joint Research Centre hosts the European Union Reference Laboratory for Food Contact Materials (EURL-FCM). One of its core tasks is to organize interlaboratory comparisons (ILCs) among appointed National Reference Laboratories (NRLs). This report presents the results of the second ILC of the EURL-FCM which focused on the determination of Di-isodecyl phthalate (DIDP) in an oil matrix. The aim was to develop and perform the validation of a method for the analysis of DIDP (as model substance for a technical mixture of phthalates) from oil (as simulant for fatty foods). This exercise was used both as proficiency testing and to validate a standard operating procedure (SOP) for the determination of DIDP in oil that was written by the EURL based on the most performant methods used by NRLs in the proficiency test of 2008. Participation of local laboratories under NRLs was encouraged (by producing 60 samples). There were 28 participants to whom samples were dispatched 24 of which submitted results. From the EURL-NRL network 23 laboratories out of 24 reported results. There were 2 guests from Germany that provided results as well. Participants were invited to report four replicates measurements under repeatability conditions. The ILC was closed permanently in the middle of October for statistical interpretation. Based on the results in this precision experiment the method performance was assessed through evaluation of the repeatability and reproducibility standard deviation (SD) according to the mechanism described in ISO 5725 [11,12]. The assigned value and its uncertainty were obtained as a consensus values after applying the robust statistics to the results obtained from the participants. Laboratory results were rated with z and z¿ scores in accordance with ISO 13528 [1]. Standard deviations for proficiency assessment (also called target standard deviations) were set based on Horwitz equation. The participation of the laboratories was regarded as satisfactory for the aim of the precision experiment with regards of the numbers of received results thanks to the proactive involvement of the NRLs-FCM. As a conclusion for participation and laboratory performance, this ILC showed: A noted increase in participation compared to the similar exercise of 2008. The number of laboratories submitting results for DIDP in oil rose from 17 to 25. This was due in part from the experience acquired in the previous year exercise as well as to the provision by the EURL of both the method description in a CEN like format as well as of the internal standard. A great increase in laboratory performance compared to 2008 with 76-92% of successful achievement of results from the participants within the tolerance limits (range 76-92% depended on concentration level considered) compared to 59% in 2008. In particular the performance at the concentration level of the SML was 80% compared to 59% for the same exercise in 2008. The harmonisation of the procedure and following a harmonised method for determination of DIDP in oil in 2009 resulted in a decrease more then 2.5 times in the reproducibility SD from 37% to 14 % for the concentration level around SML of 9 mg/kg while the repeatability SD remained almost the same ¿ 6.5%.JRC.DG.I.2-Chemical assessment and testin

    Report of the interlaboratory comparison organised by the EU Reference for Laboratory Food Contact Material - ILC02 2009- Bisphenol A in 50% aqueous ethanol (milk simulant): Laboratory performance and precision criteria of a harmonised method

    Get PDF
    The Institute for Health and Consumer Protection (IHCP) of the European Commission¿s Directorate-General Joint Research Centre hosts the Community Reference Laboratory for Food Contact Materials (EURL-FCM). One of its core tasks is to organize interlaboratory comparisons (ILCs) among appointed National Reference Laboratories (NRLs). This report presents the results of the second ILC exercise of the EURL-FCM for the year 2009, which focused on the determination of Bisphenol A (BPA) in 50% aqueous ethanol as a food simulant for milk. The general aim was to develop and perform the validation of a method for the analysis of Bisphenol A as model substance for a polycarbonate (PC), since it is a material that has typically been used as baby bottles and therefore typically in contact with mostly milk-type products. The strategy rose from the implementation of the new milk simulant 50% Ethanol (EtOH) in Commission Directive 2007/19/EC that current CEN standards for specific migration have not addressed yet. Four 50% ethanol solutions containing different concentrations of Bisphenol A were provided for analysis encompassing concentrations of relevance to exposure determination and compliance determination. The homogeneity and stability studies were performed by the EURL-FCM laboratory. Standard operating procedures (SOPs) for the two approaches were also written. There were 31 participants from twenty-five countries to whom samples were dispatched and 26 of which submitted results. The results of analyses were received and statistically interpreted. The assigned values were obtained as a consensus values after applying the robust statistics to the results obtained from the participants. Laboratory results were rated with z-scores in accordance with ISO 13528 [1]. Standard deviations for ILC comparison (also called target standard deviations) were set based on Horwitz equation and Horrat ratio 0.5. The results and preliminary report were discussed in the plenary of December 2009. The participation of the laboratories was regarded as satisfactory for the aim of the precision experiment with regards of the numbers of received results. As a conclusion of the precision exercise on the quantification of Bisphenol A in the new milk simulant 50% ethanol, this ILC showed that the validation of the method based on HPLC-FLD according to the description based mostly on the previous CEN standard TS 13130-13 was successful. The precision that can be suggested were of 15% reproducibility SD and 6% repeatability SD for the 0.0067 mg/kg level, 10% reproducibility SD and 4% repeatability SD for the 0.0.21 mg/kg level, 6% reproducibility SD and 2% repeatability SD for the 0.0.75 mg/kg level, 6% reproducibility SD and 0.2% repeatability SD for the 0.56 mg/kg level. With respect to the scarcity of data previously available in the validation performed as reported in the CEN standard TS 13130-13 (issued version of 2005), this validation also provides a great breadth of valuable detailed and traceable raw data, which should prove extremely relevant for the creation of an extension of the standard from CEN.JRC.DG.I.2-Chemical assessment and testin
    corecore