3,624 research outputs found

    Accuracy And Error Study Of Horizontal And Vertical Measurements With Single View Metrology For Road Surveying

    Get PDF
    High quality digital image can be produced and stored with cost effective embedded system, thanks to advancement of low power digital camera and hardware accelerated high definition video image compression System-on- Chip. Image recorded with these multi-megapixel digital cameras allowed the world to be digitized more accurately (compared with conventional VGA camera with low resolution) and hence enable the use of single image as the metrology tool. Using the single view geometry techniques (planar homography, vanishing points and vanishing lines) widely accepted by the community, the suitability of applying these techniques with error reduced for road surveying is studied and reported in this work

    Microflow imaging: new Doppler technology to detect low-grade inflammation in patients with arthritis

    Get PDF
    AIM: To assess the efficacy of microvascular imaging in detecting low-grade inflammation in arthritis compared with Power Doppler ultrasound (PDUS). METHOD AND MATERIALS: Patients presenting for ultrasound with arthralgia were assessed with grey-scale, PDUS and Superb Microvascular Imaging (SMI). Videoclips were stored for analysis at a later date. Three musculoskeletal radiologists scored grey-scale changes, signal on PDUS and/or SMI within these joints. If a signal was detected on both PDUS and SMI, the readers graded the conspicuity of vascular signal from the two Doppler techniques using a visual analogue scale. RESULTS: Eighty-three patients were recruited with 134 small joints assessed. Eighty-nine of these demonstrated vascular flow with both PD and SMI, whilst in five no flow was detected. In 40 joints, vascularity was detected with SMI but not with PDUS (p = 0.007). Out of the 89 joints with vascularity on both SMI and PDUS, 23 were rated as being equal; while SMI scored moderately or markedly better in 45 cases (p <0.001). CONCLUSION: SMI is a new Doppler technique that increases conspicuity of Doppler vascularity in symptomatic joints when compared to PDUS. This allows detection of low grade inflammation not visualised with Power Doppler in patients with arthritis. KEY POINTS: ‱ SMI detects vascularity with improved resolution and sensitivity compared to Power Doppler. ‱ SMI can detect low-grade inflammation not seen with Power Doppler. ‱ Earlier detection of active inflammation could have significant impact on treatment paradigms

    Effect of phacoemulsification on facility of outflow

    No full text
    PURPOSE: Phacoemulsification has been shown to reduce intraocular pressure (IOP). The mechanism of action is thought to be via increased trabecular outflow facility. However, studies on the relationship between phacoemulsification and outflow facility have been inconsistent. This study intended to examine the change in electronic Schiotz tonographic outflow facility (TOF) and IOP measurements following phacoemulsification. METHODS: Patients who were due to undergo a standard clear corneal incision phacoemulsification with intraocular lens (IOL) implantation, at St Thomas' Hospital, were invited to participate in this study. IOP was measured using Goldmann's applanation tonometer, and TOF was measured by electronic Schiotz tonography at baseline and at 3, 6 and 12 months postoperatively. RESULTS: Forty-one patients were recruited. Tonography data for 27 patients were reliable and available at all time points. Eleven cases had primary open angle glaucoma and cataract, while 16 patients had cataract only. Mean IOP reduced at every time point postoperatively significantly compared with baseline. TOF improved significantly after cataract extraction at all time points (baseline of 0.14±0.06 vs 0.18±0.09 at 3 months, P=0.02 and 0.20±0.09 at 6 months, P=0.003, 0.17±0.07 ”L/min mmHg at 12 months, P=0.04). Five contralateral eyes of patients with cataracts only who did not have any intraocular surgery during the follow-up period were used as comparison. Their IOP and TOF did not change significantly at any postoperative visits. CONCLUSION: This is the first study using electronic Schiotz tonography with documented anterior chamber depth and gonioscopy after modern cataract surgery (CS) with phacoemulsification and IOL implantation. We demonstrated that phacoemulsification increases TOF and this fully accounts for the IOP reduction following CS. ISTCRN REGISTRATION NUMBER: ISRCTN04247738

    Olfactory dysfunction is common in classical infratentorial superficial siderosis of the central nervous system

    Get PDF
    BACKGROUND: Established features of classical infratentorial superficial siderosis (iSS) include hearing loss, impaired balance, myelopathy and, less commonly, cognitive compromise. Olfactory function may be affected but dedicated studies are lacking. This study aimed to assess the prevalence of olfactory dysfunction in iSS and correlate it with auditory and cognitive functions. METHODS: Ten participants with iSS completed the University of Pennsylvania Smell Identification Test (UPSIT). The scores were compared with population norms; regression analysis was performed to evaluate associations between the scores and hearing thresholds (3-frequency average, 3FA) or the number of cognitive domains impaired. Imaging was reviewed for haemosiderin distribution and to exclude other causes of olfactory and hearing dysfunction. RESULTS: Eight of ten participants were male; the mean (standard deviation, SD) age was 52.5 (14.5) years. Olfactory hypofunction was identified in all participants and in six (60%) was moderate or completely absent. The mean UPSIT score of 25.5 (7.8) was significantly worse than population norms (difference in means - 10.0; 95% CI - 15.6 to - 4.4). Linear regression identified an association between UPSIT and hearing thresholds (R = 0.75; p = 0.013). The score decreases by 0.157 units (95% CI - 0.31 to - 0.002; p = 0.048) per unit increase in 3FA, after adjusting for hearing loss risk factors. There was no statistically significant association between UPSIT and cognitive function (R = 0.383; p = 0.397). CONCLUSION: We report a high prevalence of olfactory dysfunction in iSS, the severity of which correlated with hearing loss. Olfaction appears to be a core feature of the iSS clinical syndrome that should be assessed routinely

    Wi-Fi Sniffer Based Commuters Statistics Collection System For Reliable Bus Scheduling System

    Get PDF
    Traffic congestion issues have always been a concern for the fast growing metropolitans in which more than 90 percent of trips are made entirely by private means of transportation i.e. by car and motorcycle. As the country is actively engaged in infrastructure development especially in the transportation network to facilitate the movements of people and goods, a high demand for better public transportation is needed to reduce the issue of road congestion (percentage of GDI lost due to man hour lost in the traffic). Therefore, a cost effective Wi-Fi sniffing based bus commuters’ statistic collection system is designed and developed to study the feasibility of predicting the necessity of scheduling additional bus services when the detected number of Wi-Fi enabled devices exceeded the bus capacity. The developed system is subsequently deployed to the busiest university bus stop and the obtained result shows that variation of sniffed MAC address exhibit parallelism to the actual number of commuters waiting at the bus station as observed in the captured bus station video images. Result also shows that the MAC address based counting system can help to alert the bus management for better scheduling when the commuter at the particular bus stop is traveling to the same destination

    New techniques for a measurement of the electron's electric dipole moment

    Get PDF
    The electric dipole moment of the electron (eEDM) can be measured with high precision using heavy polar molecules. In this paper, we report on a series of new techniques that have improved the statistical sensitivity of the YbF eEDM experiment. We increase the number of molecules participating in the experiment by an order of magnitude using a carefully designed optical pumping scheme. We also increase the detection efficiency of these molecules by another order of magnitude using an optical cycling scheme. In addition, we show how to destabilise dark states and reduce backgrounds that otherwise limit the efficiency of these techniques. Together, these improvements allow us to demonstrate a statistical sensitivity of 1.8 x 10⁻ÂČ⁞ e cm after one day of measurement, which is 1.2 times the shot-noise limit. The techniques presented here are applicable to other high-precision measurements using molecules

    Health-related Quality of Life in Patients With Nonalcoholic Fatty Liver Disease: A Prospective Multi-center UK Study

    Get PDF
    BACKGROUND & AIMS: It is unclear whether health-related quality of life (HRQoL) is impaired in patients with nonalcoholic fatty liver disease (NAFLD) without advanced fibrosis and how this compares with the general population. We aimed to assess HRQoL in patients with NAFLD in comparison to the general population and any associations of fibrosis severity and metabolic comorbidities with impairments in HRQoL. METHODS: We prospectively enrolled 513 consecutive patients with NAFLD who completed the EuroQol 5-dimensional questionnaire (EQ-5D) and Chronic Liver Disease Questionnaires (CLDQ). Demographic and clinical information, liver biopsy results, and/or liver stiffness (LS) by transient elastography were recorded. A general population sub-cohort of the Health Survey for England 2018 was used as a comparator (n = 5483), and a 1:1 propensity-score (PS) matching was performed, according to age, sex, body mass index, and type 2 diabetes mellitus (T2DM). RESULTS: EQ-5D-5L utility was significantly lower in 466 PS-matched patients with NAFLD compared with PS-matched controls (0.77 ± 0.27 vs 0.84 ± 0.19; P < .001), even in those without advanced fibrosis (F ≀2 or LS <8kPa) (0.80 ± 0.24 vs 0.84 ± 0.19; P = .024). HRQoL measures (EQ-5D-5L, EQ-VAS, CLDQ) did not differ between patients with NAFLD with and without advanced fibrosis. LS was independently associated with lower EQ-5D-5L in all patients with NAFLD but not in those without advanced fibrosis. In the latter, lower EQ-5D-5L was associated with female sex, T2DM, and depression. CONCLUSIONS: Patients with NAFLD, even those without advanced fibrosis, have worse HRQoL compared with the general population. In patients with NAFLD without advanced fibrosis, HRQoL is independently associated with non-liver comorbidities but not LS. Multi-disciplinary management is therefore required in NAFLD, irrespective of fibrosis severity

    Evidence for Efimov quantum states in an ultracold gas of cesium atoms

    Full text link
    Systems of three interacting particles are notorious for their complex physical behavior. A landmark theoretical result in few-body quantum physics is Efimov's prediction of a universal set of bound trimer states appearing for three identical bosons with a resonant two-body interaction. Counterintuitively, these states even exist in the absence of a corresponding two-body bound state. Since the formulation of Efimov's problem in the context of nuclear physics 35 years ago, it has attracted great interest in many areas of physics. However, the observation of Efimov quantum states has remained an elusive goal. Here we report the observation of an Efimov resonance in an ultracold gas of cesium atoms. The resonance occurs in the range of large negative two-body scattering lengths, arising from the coupling of three free atoms to an Efimov trimer. Experimentally, we observe its signature as a giant three-body recombination loss when the strength of the two-body interaction is varied. We also detect a minimum in the recombination loss for positive scattering lengths, indicating destructive interference of decay pathways. Our results confirm central theoretical predictions of Efimov physics and represent a starting point with which to explore the universal properties of resonantly interacting few-body systems. While Feshbach resonances have provided the key to control quantum-mechanical interactions on the two-body level, Efimov resonances connect ultracold matter to the world of few-body quantum phenomena.Comment: 18 pages, 3 figure
    • 

    corecore