9 research outputs found
Recommended from our members
Alternative Donor--Acceptor Stacks from Crown Ethers and Naphthalene Diimide Derivatives: Rapid, Selective Formation from Solution and Solid State Grinding
Self assembling {pi}-conjugated molecules into ordered structures are of increasing interest in the field of organic electronics. One particular example is charge transfer complexes containing columnar alternative donor-acceptor (ADA) stacks, where neutral and ionic ground states can be readily tuned to modulate electrical, optical, and ferroelectrical properties. Aromatic-aromatic and charge transfer interactions have been the leading driving forces in assisting the self-assembly of ADA stacks. Various folding structures containing ADA stacks were assembled in solution with the aid of solvophobic or ion-binding interactions. Meanwhile, examples of solid ADA stacks, which are more appealing for practical use in devices, were obtained from cocrystalization of binary components or mesophase assembly of liquid crystals in bulk blends. Regardless of these examples, faster and more controllable approaches towards precise supramolecular order in the solid state are still highly desirable
Recommended from our members
Bendable X-ray Optics at the ALS: Design, Tuning, Performance and Applications
We review the development at the Advanced Light Source (ALS) of bendable x-ray optics widely used for focusing of beams of soft and hard x-rays. Typically, the focusing is divided in the tangential and sagittal directions into two elliptically cylindrical reflecting elements, the so-called Kirkpatrick-Baez (KB) pair [1]. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. This is in contrast to flat optics, that are simpler to manufacture and easier to measure by conventional interferometry. The figure of a flat substrate can be changed by placing torques (couples) at each end. Equal couples form a tangential cylinder, and unequal couples can approximate a tangential ellipse or parabola. We review the nature of the bending, requirements and approaches to the mechanical design, and describe a technique developed at the ALS Optical Metrology Laboratory (OML) for optimal tuning of bendable mirrors before installation in the beamline [2]. The tuning technique adapts a method previously used to adjust bendable mirrors on synchrotron radiation beamlines [3]. However, in our case, optimal tuning of a bendable mirror is based on surface slope trace data obtained with a slope measuring instrument--in our case, the long trace profiler (LTP). We show that due to the near linearity of the bending problem, the minimal set of data, necessary for tuning of two benders, consists of only three slope traces measured before and after a single adjustment of each bending couple. We provide an algorithm that was used in dedicated software for finding optimal settings for the mirror benders. The algorithm is based on the method of regression analysis with experimentally found characteristic functions of the benders. The resulting approximation to the functional dependence of the desired slope shape provides nearly final settings for the benders. Moreover, the characteristic functions of the benders found in the course of tuning, can be used for retuning of the optics to a new desired shape without removing it from the beamline and re-measuring with the LTP. The result of practical use of the developed technique to precisely tune a KB mirror used at the ALS for micro-focusing is also presented. We also describe a simple ray trace using the profiler data which shows expected performance in the beamline and compare the simulation with experimental data. In summary, we also discuss the next steps in the systematic improvement of optical performance for the application of KB pairs in synchrotron beamlines at the ALS
Recommended from our members
A velocity map imaging spectrometer for electron?ion and ion?ion coincidence experiments with synchrotron radiation
We have built a velocity imaging (VMI) spectrometer optimized for angle-resolved photoionization experiments with synchrotron radiation (SR) in the VUV and soft X-tay range. The spectrometer is equiped with four electrostatic lenses that focus the charged photoionization products onto a position-sensitive multi-hit delay-line anode. The use of two additional electrostatic lens elements as compared to the standard design of Eppink and Parker [T.J.B. Eppink and D.H. Parker, Rev. Sci. Instrum. 68 (1997) 3477]provides better focusing of an extended interaction region, which is crucial for most SR applications. Furthermore, the apparatus is equipped with a second micro-channel plate detector opposite to the VMI spectrometer, enabling electron-ion coincidence experiments and thereby mass-resolved ion spectroscopy independent of the time structure of the synchrotron radiation. First results for the photofragmentation of CO2 molecules are presented
Recommended from our members
Bendable X-ray Optics at the ALS: Design, Tuning, Performance and Applications
Recommended from our members
Analysis of Capillary Guided Laser Plasma Accelerator Experiments at LBNL
Laser wakefield acceleration experiments were carried out by using a hydrogen-filledcapillary discharge waveguide. For a 15 mm long, 200 mu m diameter capillary, quasi-monoenergetic e-beams up to 300 MeV were observed. By de-tuning discharge delay from optimum guiding performance, self-trapping was found to be stabilized. For a 33 mm long, 300 mu m capillary, a parameter regime with high energy electron beams, up to 1 GeV, was found. In this regime, the electron beam peak energy was correlated with the amount of trapped electrons
Recommended from our members
5000 groove/mm multilayer-coated blazed grating with 33percent efficiency in the 3rd order in the EUV wavelength range
We report on recent progress in developing diffraction gratings which can potentially provide extremely high spectral resolution of 105-106 in the EUV and soft x-ray photon energy ranges. Such a grating was fabricated by deposition of a multilayer on a substrate which consists ofa 6-degree blazed grating with a high groove density. The fabrication of the substrate gratings was based on scanning interference lithography and anisotropic wet etch of silicon single crystals. The optimized fabrication process provided precise control of the grating periodicity, and the grating groove profile, together with very short anti-blazed facets, and near atomically smooth surface blazed facets. The blazed grating coated with 20 Mo/Si bilayers demonstrated a diffraction efficiency in the third order as high as 33percent at an incidence angle of 11? and wavelength of 14.18 nm
Data for "A rapidly-reversible absorptive and emissive vapochromic Pt(II) pincer-based chemical sensor"
Data to accompany the article "A rapidly-reversible absorptive and emissive vapochromic Pt(II) pincer-based chemical sensor". This dataset contains data from the computational modelling carried out as part of this study, including optimised structures and simulated optical-absorption spectra
Data for "A rapidly-reversible absorptive and emissive vapochromic Pt(II) pincer-based chemical sensor"
Data to accompany the article "A rapidly-reversible absorptive and emissive vapochromic Pt(II) pincer-based chemical sensor". This dataset contains data from the computational modelling carried out as part of this study, including optimised structures and simulated optical-absorption spectra