14 research outputs found

    Towards Practical Capture of High-Fidelity Relightable Avatars

    Full text link
    In this paper, we propose a novel framework, Tracking-free Relightable Avatar (TRAvatar), for capturing and reconstructing high-fidelity 3D avatars. Compared to previous methods, TRAvatar works in a more practical and efficient setting. Specifically, TRAvatar is trained with dynamic image sequences captured in a Light Stage under varying lighting conditions, enabling realistic relighting and real-time animation for avatars in diverse scenes. Additionally, TRAvatar allows for tracking-free avatar capture and obviates the need for accurate surface tracking under varying illumination conditions. Our contributions are two-fold: First, we propose a novel network architecture that explicitly builds on and ensures the satisfaction of the linear nature of lighting. Trained on simple group light captures, TRAvatar can predict the appearance in real-time with a single forward pass, achieving high-quality relighting effects under illuminations of arbitrary environment maps. Second, we jointly optimize the facial geometry and relightable appearance from scratch based on image sequences, where the tracking is implicitly learned. This tracking-free approach brings robustness for establishing temporal correspondences between frames under different lighting conditions. Extensive qualitative and quantitative experiments demonstrate that our framework achieves superior performance for photorealistic avatar animation and relighting.Comment: Accepted to SIGGRAPH Asia 2023 (Conference); Project page: https://travatar-paper.github.io

    The 5th International Conference on Biomedical Engineering and Biotechnology (ICBEB 2016)

    Get PDF

    Experimental Study of the Hydrodynamics of an Open Channel with Algae Attached to the Side Wall

    No full text
    The construction of large-scale water diversion projects has effectively alleviated the current situation of the uneven distribution of water resources in China. However, due to the siltation of very fine sediment and organic matter on the side wall of an open channel, and the slow velocity of the side wall flow field, it is easy for epipelic algae to be produced, which affects water quality. Because prototype observation cannot be used to predict the series of flow in real time, and the calculation of the mathematical model is affected by parameter limitations, these two methods often cannot truly reflect the hydrodynamic characteristics of an open channel with epipelic algae. Therefore, by referring to the design parameters of the water diversion project channel, this study took the epipelic algae growing on the side wall of an open channel as the research object and used the scale of 1:30 to carry out a generalized flume experiment. Through the analysis of the physical characteristics of the prototype sample, and the simulation of the cohesive force between the oblique side wall and the epipelic algae, multi-group and multi-series hydrodynamic tests were carried out. The velocity distribution law and flow field distribution law were analyzed. The research results show that the presence of epipelic algae has a certain hindering effect on the flow velocity and significantly reduces the range of the peak velocity of the channel along the water depth. The position of the maximum velocity on the vertical line of the channel flow appears at the relative water depth of 0.6. In the case of small flow, the epipelic algae group only reduces the average flow rate of the channel by 5~6%; in the case of large flow, the effect of epipelic algae on the channel flow rate is minimal. This paper includes important scientific guiding significance and practical value for the regulation of water quantity and water quality safety, as well as the protection of long-distance projects

    A Multiple Source and Target Sweeping Method for Generating All Hexahedral Finite Element Meshes

    No full text
    : This paper presents an algorithm to enhance the capabilities of generating all hexahedral finite element meshes by the sweeping process. Traditional sweeping techniques are very useful and robust. They create meshes by projecting an existing single-surface mesh along a specified trajectory to a specified singletarget surface. In this process the source surface is meshed by any surface meshing algorithm while the sides that couple the source to the target are limited to a regular mapped quadrilateral mesh. This process is often called two and one half dimensional meshing. The procedure presented in this paper enhances this traditional technique by developing a projection technique that minimizes mesh distortion; and allows multiple connected surfaces to single target, multiple unconnected surfaces to single target, and multiple unconnected surfaces to multiple unconnected target sweeping. Keywords: Sweeping, Hexahedrons, Multiple Targets 1. Introduction Swept representations are base..

    Predicting Epipelic Algae Transport in Open Channels: A Flume Study to Quantify Transport Capacity and Guide Flow Management

    No full text
    The functionality of rivers and open diversion channels can be severely impacted when the epipelic algae group that grows on concrete inclined side walls, which are typical of urban rivers, joins the water flow. This study aims to increase the long-distance transport of epipelic algae groups in urban rivers and open diversion channels through flow scheduling and to anticipate their transport capacity with respect to water flow. Current research on contaminant movement is primarily based on mathematical models with limited data on flake epipelic algae types. A sidewall epipelic algae group in a flume was modeled using a generalized hydrodynamic experimental approach. Hydraulic experiments were conducted to study the physical movement form and transport capacity of the suspended epipelic algae group. This study suggests that the epipelic algae group will create transport movement without sedimentation when the velocity reaches 80–85% of the main flow velocity and settle to the bottom when it falls below 80%. This research can support the mathematical modelling of hydrodynamic transport, provide a research foundation for long-distance transport, and estimate potential gathering places and sediment amounts under different water flow conditions

    H2RSPET: a 0.5 mm resolution high-sensitivity small-animal PET scanner, a simulation study

    No full text
    With the goal of developing a total-body small-animal PET system with a high spatial resolution of ∼0.5 mm and a high sensitivity >10% for mouse/rat studies, we simulated four scanners using the graphical processing unit-based Monte Carlo simulation package (gPET) and compared their performance in terms of spatial resolution and sensitivity. We also investigated the effect of depth-of-interaction (DOI) resolution on the spatial resolution. All the scanners are built upon 128 DOI encoding dual-ended readout detectors with lutetium yttrium oxyorthosilicate (LYSO) arrays arranged in 8 detector rings. The solid angle coverages of the four scanners are all ∼0.85 steradians. Each LYSO element has a cross-section of 0.44 Ã— 0.44 mm2 and the pitch size of the LYSO arrays are all 0.5 mm. The four scanners can be divided into two groups: (1) H2RS110-C10 and H2RS110-C20 with 40 Ã— 40 LYSO arrays, a ring diameter of 110 mm and axial length of 167 mm, and (2) H2RS160-C10 and H2RS160-C20 with 60 Ã— 60 LYSO arrays, a diameter of 160 mm and axial length of 254 mm. C10 and C20 denote the crystal thickness of 10 and 20 mm, respectively. The simulation results show that all scanners have a spatial resolution better than 0.5 mm at the center of the field-of-view (FOV). The radial resolution strongly depends on the DOI resolution and radial offset, but not the axial resolution and tangential resolution. Comparing the C10 and C20 designs, the former provides better resolution, especially at positions away from the center of the FOV, whereas the latter has 2× higher sensitivity (∼10% versus ∼20%). This simulation study provides evidence that the 110 mm systems are a good choice for total-body mouse studies at a lower cost, whereas the 160 mm systems are suited for both total-body mouse and rat studies
    corecore