2,154 research outputs found
u-RANIA: a neutron detector based on \mu -RWELL technology
In the framework of the ATTRACT-uRANIA project, funded by the European
Community, we are developing an innovative neutron imaging detector based on
micro-Resistive WELL ( -RWELL) technology. The -RWELL, based on the
resistive detector concept, ensuring an efficient spark quenching mechanism, is
a highly reliable device. It is composed by two main elements: a readout-PCB
and a cathode. The amplification stage for this device is embedded in the
readout board through a resistive layer realized by means of an industrial
process with DLC (Diamond-Like Carbon). A thin layer of BC on the copper
surface of the cathode allows the thermal neutrons detection through the
release of Li and particles in the active volume. This technology
has been developed to be an efficient and convenient alternative to the He
shortage. The goal of the project is to prove the feasibility of such a novel
neutron detector by developing and testing small planar prototypes with readout
boards suitably segmented with strip or pad read out, equipped with existing
electronics or readout in current mode. Preliminary results from the test with
different prototypes, showing a good agreement with the simulation, will be
presented together with construction details of the prototypes and the future
steps of the project.Comment: Prepared for the INSTR20 Conference Proceeding for JINS
Prune cAMP phosphodiesterase binds nm23-H1 and promotes cancer metastasis
We identify a new enzymatic activity underlying metastasis in breast cancer and describe its susceptibility to therapeutic inhibition. We show that human prune (h-prune), a phosphoesterase DHH family appertaining protein, has a hitherto unrecognized cyclic nucleotide phosphodiesterase activity effectively suppressed by dipyridamole, a phosphodiesterase inhibitor. h-prune physically interacts with nm23-H1, a metastasis suppressor gene. The h-prune PDE activity, suppressed by dipyridamole and enhanced by the interaction with nm23-H1, stimulates cellular motility and metastasis processes. Out of 59 metastatic breast cancer cases analyzed, 22 (37%) were found to overexpress h-prune, evidence that this novel enzymatic activity is involved in promoting cancer metastasis
A model to explain angular distributions of and decays into and
BESIII data show a particular angular distribution for the decay of the
and mesons into the hyperons
and . More in details the angular distribution of
the decay exhibits an opposite trend
with respect to that of the other three channels: , and
. We define a model to explain the
origin of this phenomenon.Comment: 6 pages, 7 figures, to be published in Chinese Physics
The Straw Tube Trackers of the PANDA Experiment
The PANDA experiment will be built at the FAIR facility at Darmstadt
(Germany) to perform accurate tests of the strong interaction through bar pp
and bar pA annihilation's studies. To track charged particles, two systems
consisting of a set of planar, closed-packed, self-supporting straw tube layers
are under construction. The PANDA straw tubes will have also unique
characteristics in term of material budget and performance. They consist of
very thin mylar-aluminized cathodes which are made self-supporting by means of
the operation gas-mixture over-pressure. This solution allows to reduce at
maximum the weight of the mechanical support frame and hence the detector
material budget. The PANDA straw tube central tracker will not only reconstruct
charged particle trajectories, but also will help in low momentum (< 1 GeV)
particle identification via dE/dx measurements. This is a quite new approach
that PANDA tracking group has first tested with detailed Monte Carlo
simulations, and then with experimental tests of detector prototypes. This
paper addresses the design issues of the PANDA straw tube trackers and the
performance obtained in prototype tests.Comment: 7 pages,16 figure
A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector
that collects data provided by the collision in the Beijing Electron Positron
Collider II (BEPCII), hosted at the Institute of High Energy Physics of
Beijing. Since the beginning of its operation, BESIII has collected the world
largest sample of J/{\psi} and {\psi}(2s). Due to the increase of the
luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC
decreases its efficiency in the first layers up to 35% with respect to the
value in 2014. Since BESIII has to take data up to 2022 with the chance to
continue up to 2027, the Italian collaboration proposed to replace the inner
part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM).
The CGEM-IT project will deploy several new features and innovation with
respect the other current GEM based detector: the {\mu}TPC and analog readout,
with time and charge measurements will allow to reach the 130 {\mu}m spatial
resolution in 1 T magnetic field requested by the BESIII collaboration. In this
proceeding, an update of the status of the project will be presented, with a
particular focus on the results with planar and cylindrical prototypes with
test beams data. These results are beyond the state of the art for GEM
technology in magnetic field
Treatment decision-making of secondary prevention after venous thromboembolism. data from the real-life START2-POST-VTE register
Patients with venous thromboembolism (VTE) should receive a decision on the duration of anticoagulant treatment (AT) that is often not easy to make. Sixteen Italian clinical centers included patients with recent VTE in the START2-POST-VTE register and reported the decisions taken on duration of AT in each patient and the reasons for them. At the moment of this report, 472 (66.9%) of the 705 patients included in the registry were told to stop AT in 59.3% and to extend it in 40.7% of patients. Anticoagulant treatment lasted ≥3 months in >90% of patients and was extended in patients with proximal deep vein thrombosis because considered at high risk of recurrence or had thrombophilic abnormalities. d-dimer testing, assessment of residual thrombus, and patient preference were also indicated among the criteria influencing the decision. In conclusion, Italian doctors stuck to the minimum 3 months AT after VTE, while the secondary or unprovoked nature of the event was not seen as the prevalent factor influencing AT duration which instead was the result of a complex and multifactorial evaluation of each patient
Observation of in
Using a sample of events recorded with
the BESIII detector at the symmetric electron positron collider BEPCII, we
report the observation of the decay of the charmonium state
into a pair of mesons in the process
. The branching fraction is measured for the first
time to be , where the first uncertainty is
statistical, the second systematic and the third is from the uncertainty of
. The mass and width of the are
determined as MeV/ and
MeV.Comment: 13 pages, 6 figure
Measurement of proton electromagnetic form factors in in the energy region 2.00-3.08 GeV
The process of is studied at 22 center-of-mass
energy points () from 2.00 to 3.08 GeV, exploiting 688.5~pb of
data collected with the BESIII detector operating at the BEPCII collider. The
Born cross section~() of is
measured with the energy-scan technique and it is found to be consistent with
previously published data, but with much improved accuracy. In addition, the
electromagnetic form-factor ratio () and the value of the
effective (), electric () and magnetic () form
factors are measured by studying the helicity angle of the proton at 16
center-of-mass energy points. and are determined with
high accuracy, providing uncertainties comparable to data in the space-like
region, and is measured for the first time. We reach unprecedented
accuracy, and precision results in the time-like region provide information to
improve our understanding of the proton inner structure and to test theoretical
models which depend on non-perturbative Quantum Chromodynamics
- …