85 research outputs found

    Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)

    Get PDF
    Purpose. To investigate the agreement between morphometric optic nerve head parameters assessed with the confocal laser ophthalmoscope HRT III and the stereoscopic fundus camera Kowa nonmyd WX3D retrospectively. Methods. Morphometric optic nerve head parameters of 40 eyes of 40 patients with primary open angle glaucoma were analyzed regarding their vertical cup-to-disc-ratio (CDR). Vertical CDR, disc area, cup volume, rim volume, and maximum cup depth were assessed with both devices by one examiner. Mean bias and limits of agreement (95% CI) were obtained using scatter plots and Bland-Altman analysis. Results. Overall vertical CDR comparison between HRT III and Kowa nonmyd WX3D measurements showed a mean difference (limits of agreement) of −0.06 (−0.36 to 0.24). For the CDR < 0.5 group (n=24) mean difference in vertical CDR was −0.14 (−0.34 to 0.06) and for the CDR ≥ 0.5 group (n=16) 0.06 (−0.21 to 0.34). Conclusion. This study showed a good agreement between Kowa nonmyd WX3D and HRT III with regard to widely used optic nerve head parameters in patients with glaucomatous optic neuropathy. However, data from Kowa nonmyd WX3D exhibited the tendency to measure larger CDR values than HRT III in the group with CDR < 0.5 group and lower CDR values in the group with CDR ≥ 0.5

    Feasibility of monitoring compliance with intermittent occlusion therapy glasses for amblyopia treatment

    Get PDF
    Background Liquid crystal glasses use an intermittent occlusion technique and may improve compliance compared to adhesive patches. Previous studies support the effectiveness of intermittent occlusion therapy (IO therapy) glasses for amblyopia treatment. However, objective compliance for these glasses has not been measured. The purpose of this study was to investigate the feasibility of using a microsensor to monitor objective compliance with IO therapy glasses. Methods Children 3 to ≤8 years of age with unilateral amblyopia were enrolled. All subjects had optimal refractive correction (if needed) for at least 5 weeks without improvement. Subjects were prescribed IO therapy glasses, set at 30-second opaque/transparent intervals (ie, occluded 50% of wear time). Wear time was prescribed according to amblyopia severity. For each patient, objective compliance with the IO therapy glasses was monitored by means of a microsensor. Results A total of 13 subjects returned with microsensor data. Compliance varied among and within individuals. General compliance averaged 51.6% (range, 10%-97%). Mean daily compliance decreased slightly over time. On average, patients’ visual acuity improved 0.14 ± 0.15 logMAR (range, −0.1 to 0.5 logMAR). No parents reported that their child had social concerns related to the attached microsensor. Conclusions Objective compliance with IO therapy glasses can be monitored by a simple microsensor reliably. In our study cohort, objective compliance with IO therapy glasses varied among individuals, but on average it declined slightly over time

    Toxicity of heavy liquids

    No full text
    • …
    corecore