5 research outputs found

    TARGET® Intracranial Aneurysm Coiling Prospective Multicenter Registry: Final Analysis of Peri-Procedural and Long-Term Safety and Efficacy Results

    No full text
    Background and Purpose: To describe the final results of the TARGET Registry, a multicenter, real-world study of patients with intracranial aneurysms treated with new generation TARGET Coils. Methods: The TARGET Registry is a prospective, single-arm study with independent medical event monitoring and core-lab adjudication. Patients with de novo intracranial aneurysms were embolized with either TARGET-360° or helical coils in 12 US centers. The primary outcome was aneurysm packing density (PD), which was assessed immediately post-procedure. The secondary outcomes were immediate and long-term aneurysm occlusion rate using the Raymond Scale, and independent functional outcome using the modified Rankin Scale (mRS). A secondary analysis investigated the influence of the use of 100% 360-complex coils on clinical and angiographic outcomes. Results: 148 patients with 157 aneurysms met the inclusion and exclusion criteria. 58 (39.2%) patients with ruptured and 90 (61.8%) with unruptured aneurysms were treated using TARGET 360°, helical Coils, or both. Median age was 58.3 (IQR 48.1–67.4), 73% female, and 71.6% were Caucasian. Median follow-up time was 5.9 (IQR 4.0–6.9) months. The majority were treated with TARGET 360-coils (63.7%), followed by mixed and helical coils only. Peri-procedural morbidity and mortality was seen in 2.7% of patients. A good outcome at discharge (mRS 0–2) was seen in 89.9% of the full cohort, and in 84.5 and 93.3% in the ruptured and unruptured patients, respectively. The median packing density was 28.8% (IQR 20.3–41.1). Long-term complete and near complete occlusion rate was seen in 90.4% of aneurysms and complete obliteration was seen in 66.2% of the aneurysms. No significant difference in clinical and angiographic outcomes were noted between the pure 360-complex coiling vs. mixed 360-complex/Helical coiling strategies. In a multivariate analysis, predictors for long-term aneurysm occlusion were aneurysm location, immediate occlusion grade, and aneurysm size. The long-term independent functional outcome was achieved in 128/135 (94.8%) patients and all-cause mortality was seen in 3/148 (2%) patients. Conclusion: In the multicenter TARGET Registry, two-thirds of aneurysms achieved long-term complete occlusion and 91.0% achieved complete or near complete occlusion with excellent independent functional outcome. Clinical Trial Registration: www.ClinicalTrials.gov, identifier: NCT0174890

    Effect of balloon guide catheter on clinical outcomes and reperfusion in Trevo thrombectomy.

    No full text
    INTRODUCTION: The Solitaire stent retriever registry showed improved reperfusion, faster procedure times, and better outcome in acute stroke patients with large vessel occlusion treated with a balloon guide catheter (BGC) and Solitaire stent retriever compared with a conventional guide catheter. The goal of this study was to evaluate whether use of a BGC with the Trevo stent retriever improves outcomes compared with a conventional guide catheter. METHODS: The TRACK registry recruited 23 sites to submit demographic, clinical, and site adjudicated angiographic and outcome data on consecutive patients treated with the Trevo stent retriever. BGC use was at the discretion of the physician. RESULTS: 536 anterior circulation patients (of whom 279 (52.1%) had BGC placement) were included in this analysis. Baseline characteristics were notable for younger patients in the BGC group (65.4±15.3 vs 68.1±13.6, P=0.03) and lower rate of hypertension (72% vs 79%, P=0.06). Mean time from symptom onset to groin puncture was longer in the BGC group (357 vs 319 min, P=0.06).Thrombolysis in Cerebral Infarction 2b/3 scores were higher in the BGC cohort (84% vs 75.5%, P=0.01). There was no difference in reperfusion time, first pass effect, number of passes, or rescue therapy. Good clinical outcome at 3 months was superior in patients with BGC (57% vs 40%; P=0.0004) with a lower mortality rate (13% vs 23%, P=0.008). Multivariate analysis demonstrated that BGC use was an independent predictor of good clinical outcome (OR 2; 95% CI 1.3 to 3.1, P=0.001). CONCLUSIONS: In acute stroke patients presenting with anterior circulation large vessel occlusion, use of a BGC with the Trevo stent retriever resulted in improved reperfusion, improved clinical outcome, and lower mortality

    First Pass Effect in Patients Treated With the Trevo Stent-Retriever: A TRACK Registry Study Analysis.

    Get PDF
    Background and Objective: The first pass effect (FPE; achieving complete recanalization with a single thrombectomy device pass) has been shown to be associated with higher rates of good clinical outcomes in patients with acute ischemic stroke. Here, we investigate clinical and radiographic factors associated with FPE in a large U.S. post-marketing registry (TRACK, Trevo Stent-Retriever Acute Stroke). Methods: We analyzed the TRACK database (multicenter registry of 634 patients from 23 centers from March 2013 through August 2015), which 609 patients were included in the final analysis. FPE was defined as a single pass/use of device, TICI 2c/3 recanalization, and no use of rescue therapy. Analysis of individual patient data from TRACK were performed to analyze clinical and radiographic characteristics associated with FPE as well-compared clinical outcomes defined as modified Rankin Scale (mRS) score at 30 and 90 days from hospital discharge to the non-FPE group. Results: The rate of FPE in TRACK was 23% (140/609). There was no association between patient demographics and FPE, including age (p = 0.36), sex (p = 0.50), race (p = 0.50), location of occlusion (p = 0.26), baseline NIHSS (p = 0.62), or past medical history. There was no difference in the use of a balloon-guide catheter or general anesthesia (49 and 57% with FPE vs. 47 and 64%, p = 0.63 and p = 0.14, respectively). Clinical outcomes were significantly associated with FPE; 63 vs. 44% in non-FPE patients achieved mRS 0-2 at 90 days (p = 0.0004). Conclusion: Our study showed that achieving complete recanalization with a single thrombectomy pass using the Trevo device was highly beneficial. The most common clinical factors that are used to determine eligibility for endovascular therapy, such as NIHSS severity, location of occlusion or patient age were not predictive of the ability to achieve FPE. Copyright © 2020 Mokin, Primiani, Castonguay, Nogueira, Haussen, English, Satti, Chen, Farid, Borders, Veznedaroglu, Binning, Puri, Vora, Budzik, Dabus, Linfante, Janardhan, Alshekhlee, Abraham, Edgell, Taqi, Khoury, Majjhoo, Kabbani, Froehler, Finch, Ansari, Novakovic, Nguyen and Zaidat
    corecore