31 research outputs found

    Effect of Saxagliptin on Endothelial Function in Patients with Type 2 Diabetes : A Prospective Multicenter Study

    Get PDF
    The dipeptidyl peptidase-4 inhibitor saxagliptin is a widely used antihyperglycemic agent in patients with type 2 diabetes. The purpose of this study was to evaluate the effects of saxagliptin on endothelial function in patients with type 2 diabetes. This was a prospective, multicenter, interventional study. A total of 34 patients with type 2 diabetes were enrolled at four university hospitals in Japan. Treatment of patients was initially started with saxagliptin at a dose of 5 mg daily. Assessment of endothelial function assessed by flow-mediated vasodilation (FMD) and measurement of stromal cell-derived factor-1α (SDF-1α) were conducted at baseline and at 3 months after treatment with saxagliptin. A total of 31 patients with type 2 diabetes were included in the analysis. Saxagliptin significantly increased FMD from 3.1 ± 3.1% to 4.2 ± 2.4% (P = 0.032) and significantly decreased total cholesterol from 190 ± 24 mg/dL to 181 ± 25 mg/dL (P = 0.002), glucose from 160 ± 53 mg/dL to 133 ± 25 mg/dL (P < 0.001), HbA1c from 7.5 ± 0.6% to 7.0 ± 0.6% (P < 0.001), urine albumin-to-creatinine ratio from 63.8 ± 134.2 mg/g to 40.9 ± 83.0 mg/g (P = 0.043), and total SDF-1α from 2108 ± 243 pg/mL to 1284 ± 345 pg/mL (P < 0.001). These findings suggest that saxagliptin is effective for improving endothelial function

    Diagnostic Criteria of FMD and NID

    Get PDF
    Background - Diagnostic criteria of flow-mediated vasodilation (FMD), an index of endothelial function, and nitroglycerin-induced vasodilation (NID), an index of vascular smooth muscle function, of the brachial artery have not been established. The purpose of this study was to propose diagnostic criteria of FMD and NID for normal endothelial function and normal vascular smooth muscle function. Methods and Results - We investigated the cutoff values of FMD and NID in subjects with (risk group) and those without cardiovascular risk factors or cardiovascular diseases (no-risk group) in 7277 Japanese subjects (mean age 51.4±10.8 years) from the Flow-Mediated Dilation Japan study and the Flow-Mediated Dilatation Japan Registry study for analysis of the cutoff value of FMD and in 1764 Japanese subjects (62.2±16.1 years) from the registry of Hiroshima University Hospital for analysis of the cutoff value of NID. Receiver-operator characteristic curve analysis of FMD to discriminate subjects in the no-risk group from patients in the risk group showed that the optimal cutoff value of FMD to diagnose subjects in the no-risk group was 7.1%. Receiver-operator characteristic curve analysis of NID to discriminate subjects in the no-risk group from patients in the risk group showed that the optimal cutoff value of NID to diagnose subjects in the no-risk group was 15.6%. Conclusions - We propose that the cutoff value for normal endothelial function assessed by FMD of the brachial artery is 7.1% and that the cutoff value for normal vascular smooth muscle function assessed by NID of the brachial artery is 15.6% in Japanese subjects

    Sound Field Reproduction System Tracking Environmental Variations With Deconvolution

    Get PDF
    In this paper, we propose a novel sound field reproduction system using the deconvolution. In the conventional sound reproduction systems, the preprocessing filters are generally determined and fixed based on transfer functions from loudspeakers to control points in advance. However, movements of control points result in severe localization errors. Therefore, we have already proposed a sound field reproduction system using the simultaneous perturbation (SP) method which updates the filter coefficients only using error signal. However the SP method suffers from the disadvantage of slow convergence. Hence, we newly propose a sound field reproduction system using Deconvolution Algorithm (DA) which has the advantage of the fast convergence. The DA updates the filter coefficients using the signals which input to the loudspeakers and the observing microphones. Simulation results demonstrate that the proposed method can track the movements of control points and has reasonable convergence speed.APSIPA ASC 2009: Asia-Pacific Signal and Information Processing Association, 2009 Annual Summit and Conference. 4-7 October 2009. Sapporo, Japan. Poster session: Audio and Electroacoustics (5 October 2009)

    Sound Field Reproduction System Tracking Environmental Variations With Deconvolution

    No full text
    corecore