12 research outputs found

    Towards an SSVEP Based BCI With High ITR

    Get PDF
    A brain-computer interface (BCI) provides the possibility to translate brain neural activity patterns into control commands without movement by the user. In recent years, there has been increasing interest in using steady-state visual evoked potential (SSVEP) in BCI systems; the SSVEP approach provides currently the fastest and most reliable communication paradigm for the implementation of a non-invasive BCI system. However, many aspects of current system realizations need improvement, specifically in relation to speed (in terms of information transfer rate as well as time needed to perform a single command), user variability and ease of use. With these improvements in mind, this paper presents the Bremen-BCI, an online multi-channel SSVEP-based BCI system that operates on a conventional computer making use of the minimum energy combination method for extraction of power information associated with the SSVEP responses. An additional advantage of the presented methodology is that it is fully online, i.e., no calibration data for noise estimation, feature extraction, or electrode selection is needed, the system is ready to use once the subject is prepared. The SSVEP-based Bremen-BCI system with five targets, an adaptive time segment length between 0.75s and 4s, and six EEG channel locations on the occipital area, was used for online testing on 27 subjects. ALL participants were able to successfully complete spelling tasks with a mean accuracy of 93.83% and an information transfer rate (ITR) of 49.93 bit/min

    Towards an SSVEP Based BCI With High ITR

    No full text
    A brain-computer interface (BCI) provides the possibility to translate brain neural activity patterns into control commands without movement by the user. In recent years, there has been increasing interest in using steady-state visual evoked potential (SSVEP) in BCI systems; the SSVEP approach provides currently the fastest and most reliable communication paradigm for the implementation of a non-invasive BCI system. However, many aspects of current system realizations need improvement, specifically in relation to speed (in terms of information transfer rate as well as time needed to perform a single command), user variability and ease of use. With these improvements in mind, this paper presents the Bremen-BCI, an online multi-channel SSVEP-based BCI system that operates on a conventional computer making use of the minimum energy combination method for extraction of power information associated with the SSVEP responses. An additional advantage of the presented methodology is that it is fully online, i.e., no calibration data for noise estimation, feature extraction, or electrode selection is needed, the system is ready to use once the subject is prepared. The SSVEP-based Bremen-BCI system with five targets, an adaptive time segment length between 0.75s and 4s, and six EEG channel locations on the occipital area, was used for online testing on 27 subjects. ALL participants were able to successfully complete spelling tasks with a mean accuracy of 93.83% and an information transfer rate (ITR) of 49.93 bit/min

    Multiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces

    No full text

    A Novel Hybrid Mental Spelling Application Based on Eye Tracking and SSVEP-Based BCI

    No full text
    Steady state visual evoked potentials (SSVEPs)-based Brain-Computer interfaces (BCIs), as well as eyetracking devices, provide a pathway for re-establishing communication for people with severe disabilities. We fused these control techniques into a novel eyetracking/SSVEP hybrid system, which utilizes eye tracking for initial rough selection and the SSVEP technology for fine target activation. Based on our previous studies, only four stimuli were used for the SSVEP aspect, granting sufficient control for most BCI users. As Eye tracking data is not used for activation of letters, false positives due to inappropriate dwell times are avoided. This novel approach combines the high speed of eye tracking systems and the high classification accuracies of low target SSVEP-based BCIs, leading to an optimal combination of both methods. We evaluated accuracy and speed of the proposed hybrid system with a 30-target spelling application implementing all three control approaches (pure eye tracking, SSVEP and the hybrid system) with 32 participants. Although the highest information transfer rates (ITRs) were achieved with pure eye tracking, a considerable amount of subjects was not able to gain sufficient control over the stand-alone eye-tracking device or the pure SSVEP system (78.13% and 75% of the participants reached reliable control, respectively). In this respect, the proposed hybrid was most universal (over 90% of users achieved reliable control), and outperformed the pure SSVEP system in terms of speed and user friendliness. The presented hybrid system might offer communication to a wider range of users in comparison to the standard techniques

    Dynamic time window mechanism for time synchronous VEP-based BCIs-Performance evaluation with a dictionary-supported BCI speller employing SSVEP and c-VEP.

    No full text
    Brain-Computer Interfaces (BCIs) based on visual evoked potentials (VEPs) allow high communication speeds and accuracies. The fastest speeds can be achieved if targets are identified in a synchronous way (i.e., after a pre-set time period the system will produce a command output). The duration a target needs to be fixated on until the system classifies an output command affects the overall system performance. Hence, extracting a data window dedicated for the classification is of critical importance for VEP-based BCIs. Secondly, unintentional fixation on a target could easily lead to its selection. For the practical usability of BCI applications it is desirable to distinguish between intentional and unintentional fixations. This can be achieved by using threshold-based target identification methods. The study explores personalized dynamic classification time windows for threshold-based time synchronous VEP BCIs. The proposed techniques were tested employing the SSVEP and the c-VEP paradigm. Spelling performance was evaluated using an 8-target dictionary-supported BCI utilizing an n-gram word prediction model. The performance of twelve healthy participants was assessed with the information transfer rate (ITR) and accuracy. All participants completed sentence spelling tasks, reaching average accuracies of 94% and 96.3% for the c-VEP and the SSVEP paradigm, respectively. Average ITRs around 57 bpm were achieved for both paradigms

    Brain–Computer Interface Spellers: A Review

    No full text
    A Brain–Computer Interface (BCI) provides a novel non-muscular communication method via brain signals. A BCI-speller can be considered as one of the first published BCI applications and has opened the gate for many advances in the field. Although many BCI-spellers have been developed during the last few decades, to our knowledge, no reviews have described the different spellers proposed and studied in this vital field. The presented speller systems are categorized according to major BCI paradigms: P300, steady-state visual evoked potential (SSVEP), and motor imagery (MI). Different BCI paradigms require specific electroencephalogram (EEG) signal features and lead to the development of appropriate Graphical User Interfaces (GUIs). The purpose of this review is to consolidate the most successful BCI-spellers published since 2010, while mentioning some other older systems which were built explicitly for spelling purposes. We aim to assist researchers and concerned individuals in the field by illustrating the highlights of different spellers and presenting them in one review. It is almost impossible to carry out an objective comparison between different spellers, as each has its variables, parameters, and conditions. However, the gathered information and the provided taxonomy about different BCI-spellers can be helpful, as it could identify suitable systems for first-hand users, as well as opportunities of development and learning from previous studies for BCI researchers
    corecore