15 research outputs found

    Brominated flame retardants in Canadian chicken egg yolks

    Get PDF
    Chicken eggs categorised as conventional, omega-3 enriched, free range and organic were collected at grading stations in three regions of Canada between 2005 and 2006. Free run eggs, which were only available for collection from two regions, were also sampled during this time frame. Egg yolks from each of these egg types (n = 162) were analysed to determine brominated flame retardant levels, specifically polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD). PBDEs were detected in 100% of the 162 samples tested, while HBCD was observed in 85% of the egg yolks. Total PBDE concentrations in egg yolks ranged from 0.018 to 20.9 ng g−1 lipid (median = 3.03 ng g−1 lipid), with PBDE 209 identified as being the major contributor to ΣPBDE concentrations. In addition to PBDE 209, PBDE 99, 47, 100, 183 and 153 were important contributors to ΣPBDE concentrations. Total HBCD concentrations ranged from below the limit of detection to a maximum concentration of 71.9 ng g−1 lipid (median = 0.053 ng g−1 lipid). The α-isomer was the dominant contributor to ΣHBCD levels in Canadian egg yolks and was the most frequently detected HBCD isomer. ΣPBDE levels exhibited large differences in variability between combinations of region and type. ΣHBCD concentrations were not significantly different among regions, although differences were observed between the different types of egg yolks analysed in the present study

    A round robin approach to the analysis of bisphenol a (BPA) in human blood samples

    Full text link
    BACKGROUND: Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contribute BPA to serum; 2) to identify sensitive and precise methods to accurately measure unconjugated BPA (uBPA) and BPA-glucuronide (BPA-G), a metabolite, in serum; and 3) to evaluate whether inadvertent hydrolysis of BPA-G occurs during sample handling and processing. METHODS: Four laboratories participated in this Round Robin. Laboratories screened materials to identify BPA contamination in collection and analysis materials. Serum was spiked with concentrations of uBPA and/or BPA-G ranging from 0.09-19.5 (uBPA) and 0.5-32 (BPA-G) ng/mL. Additional samples were preserved unspiked as ‘environmental’ samples. Blinded samples were provided to laboratories that used LC/MSMS to simultaneously quantify uBPA and BPA-G. To determine whether inadvertent hydrolysis of BPA metabolites occurred, samples spiked with only BPA-G were analyzed for the presence of uBPA. Finally, three laboratories compared direct and indirect methods of quantifying BPA-G. RESULTS: We identified collection materials and reagents that did not introduce BPA contamination. In the blinded spiked sample analysis, all laboratories were able to distinguish low from high values of uBPA and BPA-G, for the whole spiked sample range and for those samples spiked with the three lowest concentrations (0.5-3.1 ng/ml). By completion of the Round Robin, three laboratories had verified methods for the analysis of uBPA and two verified for the analysis of BPA-G (verification determined by: 4 of 5 samples within 20% of spiked concentrations). In the analysis of BPA-G only spiked samples, all laboratories reported BPA-G was the majority of BPA detected (92.2 – 100%). Finally, laboratories were more likely to be verified using direct methods than indirect ones using enzymatic hydrolysis. CONCLUSIONS: Sensitive and accurate methods for the direct quantification of uBPA and BPA-G were developed in multiple laboratories and can be used for the analysis of human serum samples. BPA contamination can be controlled during sample collection and inadvertent hydrolysis of BPA conjugates can be avoided during sample handling
    corecore