205 research outputs found
Converting 15-Minute Interval Electricity Load Data into Reduced Demand, Energy Reduction and Cash Flow
The file with the "a" is the PowerPoint presentation given at the Hot and Humid Conference.Whole-building-electric (WBE) 15-minute interval data is an extremely low-cost, easy approach to reap an immediate reduction in energy consumption. With the advance of lower cost Internet based metering technology integrated with TCP/IP Internet communications, equipment costs and installation issues are not the issues as were in the past. The challenge is to be able to interpret the data and then implement actions to correct operational and equipment problems and anomalies. This paper will address the types of data acquisition equipment and systems available and the different components of a data. Lastly, actual graphs of data will be presented to demonstrate how to dissect and analyze a data set and then implement measures that will optimize operations and maintenance of which will effect a reduction in energy costs.Energy Knowledge Grou
Trends in Drug Utilization, Glycemic Control, and Rates of Severe Hypoglycemia, 2006-2013.
ObjectiveTo examine temporal trends in utilization of glucose-lowering medications, glycemic control, and rate of severe hypoglycemia among patients with type 2 diabetes (T2DM).Research design and methodsUsing claims data from 1.66 million privately insured and Medicare Advantage patients with T2DM from 2006 to 2013, we estimated the annual 1) age- and sex-standardized proportion of patients who filled each class of agents; 2) age-, sex-, race-, and region-standardized proportion with hemoglobin A1c (HbA1c) <6%, 6 to <7%, 7 to <8%, 8 to <9%, ≥9%; and 3) age- and sex-standardized rate of severe hypoglycemia among those using medications. Proportions were calculated overall and stratified by age-group (18-44, 45-64, 65-74, and ≥75 years) and number of chronic comorbidities (zero, one, and two or more).ResultsFrom 2006 to 2013, use increased for metformin (from 47.6 to 53.5%), dipeptidyl peptidase 4 inhibitors (0.5 to 14.9%), and insulin (17.1 to 23.0%) but declined for sulfonylureas (38.8 to 30.8%) and thiazolidinediones (28.5 to 5.6%; all P < 0.001). The proportion of patients with HbA1c <7% declined (from 56.4 to 54.2%; P < 0.001) and with HbA1c ≥9% increased (9.9 to 12.2%; P < 0.001). Glycemic control varied by age and was poor among 23.3% of the youngest and 6.3% of the oldest patients in 2013. The overall rate of severe hypoglycemia remained the same (1.3 per 100 person-years; P = 0.72), declined modestly among the oldest patients (from 2.9 to 2.3; P < 0.001), and remained high among those with two or more comorbidities (3.2 to 3.5; P = 0.36).ConclusionsDuring the recent 8-year period, the use of glucose-lowering drugs has changed dramatically among patients with T2DM. Overall glycemic control has not improved and remains poor among nearly a quarter of the youngest patients. The overall rate of severe hypoglycemia remains largely unchanged
Search for Neutrinoless Double-Beta Decay in Xe with EXO-200
We report on a search for neutrinoless double-beta decay of Xe with
EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background
of ~1.5 x 10^{-3} /(kg yr keV) in the region of interest. This
sets a lower limit on the half-life of the neutrinoless double-beta decay
(Xe) > 1.6 x 10 yr (90% CL),
corresponding to effective Majorana masses of less than 140-380 meV, depending
on the matrix element calculation
Investigation of radioactivity-induced backgrounds in EXO-200
The search for neutrinoless double-beta decay (0{\nu}{\beta}{\beta}) requires
extremely low background and a good understanding of their sources and their
influence on the rate in the region of parameter space relevant to the
0{\nu}{\beta}{\beta} signal. We report on studies of various {\beta}- and
{\gamma}-backgrounds in the liquid- xenon-based EXO-200 0{\nu}{\beta}{\beta}
experiment. With this work we try to better understand the location and
strength of specific background sources and compare the conclusions to
radioassay results taken before and during detector construction. Finally, we
discuss the implications of these studies for EXO-200 as well as for the
next-generation, tonne-scale nEXO detector.Comment: 9 pages, 7 figures, 3 table
A simple radionuclide-driven single-ion source
We describe a source capable of producing single barium ions through nuclear
recoils in radioactive decay. The source is fabricated by electroplating 148Gd
onto a silicon {\alpha}-particle detector and vapor depositing a layer of BaF2
over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+
ions from the BaF2 layer and emit them in the surrounding environment. The
simultaneous detection of an {\alpha} particle in the substrate detector allows
for tagging of the nuclear decay and of the Ba+ emission. The source is simple,
durable, and can be manipulated and used in different environments. We discuss
the fabrication process, which can be easily adapted to emit most other
chemical species, and the performance of the source
A magnetically-driven piston pump for ultra-clean applications
A magnetically driven piston pump for xenon gas recirculation is presented.
The pump is designed to satisfy extreme purity and containment requirements, as
is appropriate for the recirculation of isotopically enriched xenon through the
purification system and large liquid xenon TPC of EXO-200. The pump, using
sprung polymer gaskets, is capable of pumping more than 16 standard liters per
minute (SLPM) of xenon gas with 750 torr differential pressure.Comment: 6 pages, 5 figure
- …