    Predictors of aortic growth in uncomplicated type B aortic dissection from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) database

    No full text
    Background: The high-risk patient cohort of uncomplicated type B aortic dissections (uTBADs) needs to be clarified. We compared uTBAD patients treated with best medical treatment (BMT), with and without aortic growth, from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) trial database. Furthermore, we looked for trends in outcome for aortic growth and remodeling after BMT and thoracic endovascular aortic repair (TEVAR) and BMT (TEVAR+BMT). Methods: BMT patients with available baseline and a 1-year follow-up arterial computed tomography scan were identified. True lumen and false lumen diameter was assessed at baseline and at follow-up. Patients with false lumen growth (group I) and without false lumen growth (group II) were compared. Predictors of false lumen and total lumen (aortic) growth were identified. Lastly, BMT outcomes were compared with BMT+TEVAR for false lumen thrombosis and change in false lumen and total aortic diameter in four sections: 0 to 10 cm (A), 10 to 20 cm (B), 20 to 30 cm (C), and 30 to 40 cm (D) from the left subclavian artery. Results: The dissection was significantly longer in group I than in group II (43.2 +/- 4.9 cm vs 30.4 +/- 8.8 cm; P = .002). The number of vessels originating from the false lumen at baseline was identified as an independent predictor of false lumen growth (odds ratio, 22.1; 95% confidence interval, 1.01-481.5; P = .049). Increasing age was a negative predictor of total aortic diameter growth (odds ratio, 0.902; 95% confidence interval, 0.813-1.00; P = .0502). The proximal sections A and B showed complete thrombosis in 80.6% in the BMT+TEVAR group compared with 9.5% in the BMT group. In these sections, changes from patent to partial or partial to complete thrombosis were observed in 90.3% of the TEVAR+BMT group vs 31.0% in the BMT group. In sections C and D, the change in thrombosis was 74.1% for the TEVAR+BMT group vs 20.6% for the BMT group. The false lumen diameter increase at section C was larger in the BMT group. Total lumen diameter decreased in sections A and B in the TEVAR+BMT group compared with an increase in the BMT group (-4.8 mm vs +2.9 mm, and -1.5 mm vs +3.8 mm, respectively). Sections C and D showed minimal and comparable expansion in both treatment groups. Conclusions: The new imaging analysis of the ADSORB trial patients identified the number of vessels originating from the false lumen as an independent predictor of false lumen growth in uTBAD patients. Increasing age was a negative predictor of aortic growth. Our analysis may help to identify which uTBAD patients are at higher risk and should receive TEVAR or be monitored closely during follow-up

    Microvascular hemodynamics in human hypothermic circulatory arrest and selective antegrade cerebral perfusion

    No full text
    Objective: The behavior of the human microcirculation in the setting of cardiac arrest is largely unknown. Animal experiments have consistently revealed that global hemodynamics do not necessarily reflect microvascular perfusion. In addition, the time it takes for capillary blood flow to stop after the heart arrests is debated. Estimations range from 50 seconds to 5 mins, but data in humans are lacking. Aortic arch surgery frequently necessitates deep hypothermic circulatory arrest and subsequent selective antegrade cerebral perfusion. To elucidate microvascular behavior surrounding cessation of human circulation, we used sublingual microvascular imaging in this setting. Design: Prospective, observational study. Setting: Operating room of a large tertiary referral center for cardiac surgery. Patients: Seven patients undergoing elective aortic arch repair. Interventions: We used sidestream dark field imaging to study the sublingual microcirculation immediately before circulatory arrest, during circulatory arrest, and immediately after selective antegrade cerebral perfusion. Measurements and Main Results: Results are reported as mean (SD) unless indicated otherwise. Before circulatory arrest, perfused vessel density was 6.41 (1.18) for small ( 20 mu m) microvessels. Microvascular flow index was a median of 3.0 (interquartile range 3.0-3.0) for both vessel sizes. After circulatory arrest, there was no equilibration of arterial and venous blood pressure before onset of selective antegrade cerebral perfusion after 59 (17) secs (range, 40-80 secs). Flow in small microvessels came to a complete stop after 45 (9) secs (range, 34-57 secs) after transition to circulatory arrest. However, flow in larger microvessels did not completely stop before selective antegrade cerebral perfusion started. Selective antegrade cerebral perfusion restored microvascular flow, reaching precirculatory arrest levels after 45 (27) secs (range, 20-85 secs). Conclusions: In a controlled surgical setting, circulatory arrest in humans induces a complete sublingual small microvessel shutdown within 1 min. However, flow in larger microvessels persists. Selective antegrade cerebral perfusion was able to restore microvascular flow to precirculatory arrest levels within a similar timeframe. (Crit Care Med 2010; 38:1548-1553

    Predictors of aortic growth in uncomplicated type B aortic dissection from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) database

    No full text
    International audienceBACKGROUND:The high-risk patient cohort of uncomplicated type B aortic dissections (uTBADs) needs to be clarified. We compared uTBAD patients treated with best medical treatment (BMT), with and without aortic growth, from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) trial database. Furthermore, we looked for trends in outcome for aortic growth and remodeling after BMT and thoracic endovascular aortic repair (TEVAR) and BMT (TEVAR+BMT).METHODS:BMT patients with available baseline and a 1-year follow-up arterial computed tomography scan were identified. True lumen and false lumen diameter was assessed at baseline and at follow-up. Patients with false lumen growth (group I) and without false lumen growth (group II) were compared. Predictors of false lumen and total lumen (aortic) growth were identified. Lastly, BMT outcomes were compared with BMT+TEVAR for false lumen thrombosis and change in false lumen and total aortic diameter in four sections: 0 to 10 cm (A), 10 to 20 cm (B), 20 to 30 cm (C), and 30 to 40 cm (D) from the left subclavian artery.RESULTS:The dissection was significantly longer in group I than in group II (43.2 ± 4.9 cm vs 30.4 ± 8.8 cm; P = .002). The number of vessels originating from the false lumen at baseline was identified as an independent predictor of false lumen growth (odds ratio, 22.1; 95% confidence interval, 1.01-481.5; P = .049). Increasing age was a negative predictor of total aortic diameter growth (odds ratio, 0.902; 95% confidence interval, 0.813-1.00; P = .0502). The proximal sections A and B showed complete thrombosis in 80.6% in the BMT+TEVAR group compared with 9.5% in the BMT group. In these sections, changes from patent to partial or partial to complete thrombosis were observed in 90.3% of the TEVAR+BMT group vs 31.0% in the BMT group. In sections C and D, the change in thrombosis was 74.1% for the TEVAR+BMT group vs 20.6% for the BMT group. The false lumen diameter increase at section C was larger in the BMT group. Total lumen diameter decreased in sections A and B in the TEVAR+BMT group compared with an increase in the BMT group (-4.8 mm vs +2.9 mm, and -1.5 mm vs +3.8 mm, respectively). Sections C and D showed minimal and comparable expansion in both treatment groups.CONCLUSIONS:The new imaging analysis of the ADSORB trial patients identified the number of vessels originating from the false lumen as an independent predictor of false lumen growth in uTBAD patients. Increasing age was a negative predictor of aortic growth. Our analysis may help to identify which uTBAD patients are at higher risk and should receive TEVAR or be monitored closely during follow-up

    External validation of the preHEART score and comparison with current clinical risk scores for prehospital risk assessment in patients with suspected NSTE-ACS

    No full text
    Background: Emergency Medical Services (EMS) studies have shown that prehospital risk stratification and triage decisions in patients with suspected non-ST-elevation acute coronary syndrome (NSTE-ACS) can be improved using clinical risk scores with point-of-care (POC) troponin. In current EMS studies, three different clinical risk scores are used in patients suspected of NSTE-ACS: the prehospital History, ECG, Age, Risk and Troponin (preHEART) score, History, ECG, Age, Risk and Troponin (HEART) score and Troponin-only Manchester Acute Coronary Syndromes (T-MACS). The preHEART score lacks external validation and there exists no prospective comparative analysis of the different risk scores within the prehospital setting. The aim of this analysis is to externally validate the preHEART score and compare the diagnostic performance of the these three clinical risk scores and POC-troponin. Methods: Prespecified analysis from a prospective, multicentre, cohort study in patients with suspected NSTE-ACS who were transported to an ED between April 2021 and December 2022 in the Netherlands. Risk stratification is performed by EMS personnel using preHEART, HEART, T-MACS and POC-troponin. The primary end point was the hospital diagnosis of NSTE-ACS. The diagnostic performance was expressed as area under the receiver operating characteristic (AUROC), sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV). Results: A total of 823 patients were included for external validation of the preHEART score, final hospital diagnosis of NSTE-ACS was made in 29% (n=235). The preHEART score classified 27% as low risk, with a sensitivity of 92.8% (95% CI 88.7 to 95.7) and NPV of 92.3% (95% CI 88.3 to 95.1). The preHEART classified 9% of the patients as high risk, with a specificity of 98.5% (95% CI 97.1 to 99.3) and PPV of 87.7% (95% CI 78.3 to 93.4). Data for comparing clinical risk scores and POC-troponin were available in 316 patients. No difference was found between the preHEART score and HEART score (AUROC 0.83 (95% CI 0.78 to 0.87) vs AUROC 0.80 (95% CI 0.74 to 0.85), p=0.19), and both were superior compared with T-MACS (AUROC 0.72 (95% CI 0.66 to 0.79), p≤0.001 and p=0.03, respectively) and POC-troponin measurement alone (AUROC 0.71 (95% CI 0.64 to 0.78), p<0.001 and p=0.01, respectively). Conclusion: On external validation, the preHEART demonstrates good overall diagnostic performance as a prehospital risk stratification tool. Both the preHEART and HEART scores have better overall diagnostic performance compared with T-MACS and sole POC-troponin measurement. These data support the implementation of clinical risk scores in prehospital clinical pathways

    Does Intraoperative Fibrinogen Affect Blood Loss or Transfusion Practice After Aortic Arch Surgery: A Prematurely Ended Randomized Trial

    No full text
    Cardiovascular surgery is often complicated by significant bleeding due to perioperative coagulopathy. The effectiveness of treatment with fibrinogen concentrate to reduce the perioperative blood transfusion rate after thoracic aortic replacement surgery in prior studies has shown conflicting results. Therefore, we conducted a double-blind randomized controlled trial to investigate if a single dose of intraoperative fibrinogen administration reduced blood loss and allogeneic transfusion rate after elective surgery for thoracic arch aneurysm with deep hypothermic circulatory arrest. Twenty patients were randomized to fibrinogen concentrate ( N  = 10) or placebo ( N  = 10). The recruitment of study patients was prematurely ended due to a low inclusion rate. Perioperative transfusion, 5-minute bleeding mass after study medication and postoperative blood loss were not different between the groups with fibrinogen concentrate or placebo. Due to small volumes of postoperative blood loss and premature study termination, a beneficial effect of fibrinogen concentrate on the number of blood transfusions could not be established. However, treatment with fibrinogen efficiently restored fibrinogen levels and clot strength to preoperative values with a more effective preserved postoperative thrombin generation capacity. This result might serve as a pilot for further multicenter studies to assess the prospective significance of automated and standardized thrombin generation as a routine assay for monitoring perioperative coagulopathy and its impact on short- and long-term operative results