61 research outputs found

    Method for performing cerebral perfusion-weighted MRI in neonates

    Get PDF
    Cerebral perfusion-weighted imaging (PWI) in neonates is known to be technically difficult and there are very few published studies on its use in preterm infants. In this paper, we describe one convenient method to perform PWI in neonates, a method only recently used in newborns. A device was used to manually inject gadolinium contrast material intravenously in an easy, quick and reproducible way. We studied 28 newborn infants, with various gestational ages and weights, including both normal infants and those suffering from different brain pathologies. A signal intensity-time curve was obtained for each infant, allowing us to build perfusion maps. This technique offered a fast and easy method to manually inject a bolus gadolinium contrast material, which is essential in performing PWI in neonates. Cerebral PWI is technically feasible and reproducible in neonates of various gestational age and with various pathologies

    Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis.

    Get PDF
    BACKGROUND: The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO(TM) is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. OBJECTIVE: To evaluate the potential of VEO(TM) on diagnostic image quality and dose reduction in pediatric chest CT examinations. MATERIALS AND METHODS: Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. RESULTS: At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. CONCLUSIONS: At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection

    Lemierre's syndrome, reemergence of a forgotten disease: a case report

    Get PDF
    Lemierre's syndrome is a rare disorder of young adults caused by the anaerobic bacterium, Fusobacterium necrophorum and occasionally by other Fusobacterium species (F. nucleatum, F. mortiferum and F. varium etc). The condition is characterized by a primary oropharyngeal infection with evidence of septic thrombophlebitis, exhibited by positive blood cultures, clinical or radiographic evidence of internal jugular vein thrombosis, and at least one metastatic focus. The incidence of Lemierre's syndrome is reported to be nearly one in a million. In the pre-antibiotic era, Lemierre's syndrome followed a fulminant, often fatal course. During the 1960s and 1970s, the syndrome was rarely reported when penicillin was commonly prescribed to treat oropharyngeal infections. Today, antibiotic-resistant organisms are a major concern, thus causing more prudent prescribing of antibiotics. We present a case report of a 27-year-old man with worsening pharyngitis, which illustrates that subsequent reemergence of this often forgotten disease may become more common in clinical setting

    The contribution of Swiss scientists to the assessment of energy metabolism

    Get PDF
    Although Switzerland is considered a small country, it has its share in discoveries, inventions and developments for the assessment of energy metabolism. This includes seminal contributions to respiratory and metabolic physiology and to devices for measuring energy expenditure by direct and indirect calorimetry in vivo in humans and small animals (as well as in vitro in organs/tissues), for the purpose of evaluating the basic nutritional requirements. A strong momentum came during World War II when it was necessary to evaluate the energy requirements of soldiers protecting the country by assessing their energy expenditure, as well as to determine the nutritional needs of the Swiss civil population in time of war when food rationing was necessary to ensure national neutrality and independence. A further impetus came in the 1970s at the start of the obesity epidemics, toward a better understanding of the metabolic basis of obesity, ranging from the development of whole-body concepts to molecular mechanisms. In a trip down memory lane, this review focuses on some of the earlier leading Swiss scientists who have contributed to a better understanding of the field

    Echography of pulmonary sequestration

    No full text
    Pulmonary sequestration is a rare congenital disorder in which a portion of normal lung tissue lacks normal connections with the tracheo-bronchial tree and the pulmonary arteries. We report on three cases of left lower lobe extrapleural sequestrations that have been studied with ultrasound since 1980. In the two more recent cases demonstration of the feeding vessel originating directly in the abdominal aorta by real-time ultrasound permitted very rapid non-invasive diagnosis of the malformation. We recommend that a search should be made for such an aberrant vessel with real-time ultrasound whenever a pulmonary sequestration is suspected

    Angeboren-pulmonale Sequestration

    No full text

    Plasminogen activator inhibitor 1 and plasminogen activator inhibitor 2 in various disease states.

    No full text
    The association of increased PA-inhibitor (PAI) activity and of PAI-1 and PAI-2 antigen levels with different pathological conditions was studied in a collective of over 300 patients. PAI-1 and PAI-2 levels were measured by specific radioimmunoassays. A good correlation was observed of PAI activity with PAI-1 antigen (r = 0.718; p less than 0.0001) but not with PAI-2 (r = 0.070; n.s.). Both in the controls and in the patients, PAI activity and PAI-1 antigen showed an extremely large range of values. PAI activity ranged from 0.5 to 68 U/ml and PAI-1 antigen from 6 to 600 ng/ml. Increased PAI activity and PAI-1 antigen was observed in patients with malignant tumors, cardiovascular or thromboembolic disease, in the postoperative phase, with hepatic insufficiency, after trauma and after extracorporeal circulation. The large spectrum of disease states with increased PAI activity and PAI-1 antigen reinforces previous suggestions that PAI-1 is an acute phase reactant. After extracorporeal circulation, PAI activity and PAI-1 concentrations strongly increased within one hour, remained elevated for at least one week and returned to preoperation values within 7 days. PAI-2 values ranged from below detection limit (15 ng/ml), observed in half of the plasmas, to 485 ng/ml in a pregnant woman. High values of PAI-2 were only observed in pregnancy

    An uncommon G375C substitution in a newborn with achondroplasia.

    No full text
    We report a G-to-T de novo transversion mutation causing the substitution of a glycine with a cysteine (G375C) in a newborn with achondroplasia. This rare observation confirms allelic heterogeneity