1,833 research outputs found

    A symptomatic pelvic rib

    Get PDF
    Pelvic rib is a rare anomaly where ectopic rib is found in a pelvic region. It is usually found occasionally in asymptomatic patients. We report a case of 15-year-old male, diagnosed with a symptomatic pelvic rib. It had an unusual presentation creating a pseudotumour associated with pain and reduced range of motion in the hip joint. Patient was operated on with good result and final diagnosis was confirmed in pathological examination. (Folia Morphol 2018; 77, 2: 406–408

    Persistent left superior vena cava with an absent right superior vena cava in a 72-year-old male with multivessel coronary artery disease

    Get PDF
    Congenital anomalies of systemic veins are usually asymptomatic and foundincidentally during ultrasonography, computed tomography (CT) or magneticresonance examinations performed for other clinical indications. Persistent leftsuperior vena cava (PLSVC) with absent right superior vena cava (RSVC) is thecongenital aberration in the thoracic venous system which occurs in only 0.09%to 0.13% of patients who have congenital heart defects. In this paper, we presentthe extremely rare case of a 72-year-old male with PLSVC associated withan absence of RSVC, referred for coronary CT angiography. Multidetector CTangiography is a powerful tool for the detection of venous anomalies, which isessential before invasive procedures such as the implantation of pacemakers

    Prevalence of congenital coronary artery anomalies and variants in 726 consecutive patients based on 64-slice coronary computed tomography angiography

    Get PDF
      Background: Coronary computed tomography angiography (CCTA) is helpful in making a precise noninvasive evaluation of coronary anatomy, allowing concomitant evaluation of other cardiac structures. The aim of this study was to determine the prevalence of coronary artery variations detected by 64-slice mutidetector CT. Materials and methods: The results of ECG-gated CCTA in 726 consecutive patients (mean age 58 years) were analysed retrospectively. The main indicationsfor CCTA were a typical chest pain, angina pectoris, screening for coronary artery disease and determination of the patency of bypass grafts or stents. Acquisitionwas performed with a 64-detector CT scanner with retrospective ECG gating. Imaging results were assessed by experienced cardiovascular radiologist. Results: The overall incidence of coronary artery anomalies was 1.1% (8 out of 726 participants). The most common anomaly was an anomalous origin of the circumflex artery from the right coronary sinus with a retroaortic course (4 patients,0.6%), followed by origin of right coronary artery from the left coronary sinus (2 patients, 0.3%). One patient with abnormal origin of the left main artery from the right coronary sinus (0.1%) and 1 patient with a circumflex artery origin from the proximal segment of the right coronary artery (0.1%) were observed, both with retroartic course. Conclusions: CCTA is a noninvasive imaging technique useful for the precise evaluation of variations of the coronary arteries. This study shows similar results to other reports on this subject.

    The Optical Alignment System of the ZEUS MicroVertex Detector

    Full text link
    The laser alignment system of the ZEUS microvertex detector is described. The detector was installed in 2001 as part of an upgrade programme in preparation for the second phase of electron-proton physics at the HERA collider. The alignment system monitors the position of the vertex detector support structure with respect to the central tracking detector using semi-transparent amorphous-silicon sensors and diode lasers. The system is fully integrated into the general environmental monitoring of the ZEUS detector and data has been collected over a period of 5 years. The primary aim of defining periods of stability for track-based alignment has been achieved and the system is able to measure movements of the support structure to a precision around 10μ10 \mum.Comment: 38 pages; 17 figure

    Measurement of the neutrino mass splitting and flavor mixing by MINOS

    Get PDF
    Measurements of neutrino oscillations using the disappearance of muon neutrinos from the Fermilab NuMI neutrino beam as observed by the two MINOS detectors are reported. New analysis methods have been applied to an enlarged data sample from an exposure of 7.25imes10207.25 imes 10^{20} protons on target. A fit to neutrino oscillations yields values of ∣Deltam2∣=(2.32−0.08+0.12)imes10−3|Delta m^2| = (2.32^{+0.12}_{-0.08}) imes10^{-3},eV2^2 for the atmospheric mass splitting and m sin^2!(2 heta) > 0.90 (90%,C.L.) for the mixing angle. Pure neutrino decay and quantum decoherence hypotheses are excluded at 7 and 9 standard deviations, respectively
    • …
    corecore