34 research outputs found

    Production of Oriented Fibers out of Poly(Hydroxybutyrate/Hydroxyvalerate) Copolymers and Testing of Mechanical Stability under Static and Cyclic Loads

    Get PDF
    We investigated the process of production of oriented fibers by melt spinning of biodegradable hydroxybutyrate and hydroxyvalerate (PHBV) copolymers. It was revealed that temperature has a large effect on the stability of extrusion and quality of fibers, and the optimal paramter values were found. We showed that the diameter of fibers and orientation degree depend on the spinning rate which can vary in a wide range (from 2-3 to 40 m/min), not affecting the quality of fibers. We studied the extensibility and deformability of fibers at different temperatures and found the conditions allowing to produce fibers with the diameter of 0.17-0.20 mm with high mechanical characteristics (strength 306 MPa, elasticity modulus 3 GPa, elongation at break 24%), that were stable during the 3 month period of observation. We obtained and analyzed extension curves on which three areas were fixed: linear elasticity, visible deformation, totally nonreversible deformation, which is typical for the elongation curves of polymer elastomers. It was stated that the produced fibers have high mechanical stability at static and cyclic loading conditions (up to 100 MPa); in the area of linear elasticity the deformation of fibers is practically totally reversible after 1000 cycles of loading

    Production of Oriented Fibers out of Poly(Hydroxybutyrate/Hydroxyvalerate) Copolymers and Testing of Mechanical Stability under Static and Cyclic Loads

    No full text
    We investigated the process of production of oriented fibers by melt spinning of biodegradable hydroxybutyrate and hydroxyvalerate (PHBV) copolymers. It was revealed that temperature has a large effect on the stability of extrusion and quality of fibers, and the optimal paramter values were found. We showed that the diameter of fibers and orientation degree depend on the spinning rate which can vary in a wide range (from 2-3 to 40 m/min), not affecting the quality of fibers. We studied the extensibility and deformability of fibers at different temperatures and found the conditions allowing to produce fibers with the diameter of 0.17-0.20 mm with high mechanical characteristics (strength 306 MPa, elasticity modulus 3 GPa, elongation at break 24%), that were stable during the 3 month period of observation. We obtained and analyzed extension curves on which three areas were fixed: linear elasticity, visible deformation, totally nonreversible deformation, which is typical for the elongation curves of polymer elastomers. It was stated that the produced fibers have high mechanical stability at static and cyclic loading conditions (up to 100 MPa); in the area of linear elasticity the deformation of fibers is practically totally reversible after 1000 cycles of loading

    The mTOR Pathway in Pluripotent Stem Cells: Lessons for Understanding Cancer Cell Dormancy

    No full text
    Currently, the success of targeted anticancer therapies largely depends on the correct understanding of the dormant state of cancer cells, since it is increasingly regarded to fuel tumor recurrence. The concept of cancer cell dormancy is often considered as an adaptive response of cancer cells to stress, and, therefore, is limited. It is possible that the cancer dormant state is not a privilege of cancer cells but the same reproductive survival strategy as diapause used by embryonic stem cells (ESCs). Recent advances reveal that high autophagy and mTOR pathway reduction are key mechanisms contributing to dormancy and diapause. ESCs, sharing their main features with cancer stem cells, have a delicate balance between the mTOR pathway and autophagy activity permissive for diapause induction. In this review, we discuss the functioning of the mTOR signaling and autophagy in ESCs in detail that allows us to deepen our understanding of the biology of cancer cell dormancy

    The neuromuscular system in flatworms: serotonin and FMRFamide immunoreactivities, and musculature in Prodistomum alaskense (Digenea: Lepocreadiidae), an endemic fish parasite of the north-western Pacific

    No full text
    Using the immunocytochemical method and confocal scanning laser microscopy, the pioneering data are obtained on the muscle system organization and presence and localization of biogenic amine serotonin and FMRFamide-related peptides in the nervous system of trematode Prodistomum alaskense (Ward and Fillingham, 1934) Bray and Merrett, 1998 (family Lepocreadiidae). This flatworm is an intestinal parasite of endemic representatives of marine fauna of the north-western Pacific Ocean – the prowfish, Zaprora silenus Jordan, 1896 and the lumpfish, Aptocyclus ventricosus Pallas, 1769. The article provides data of scanning electron microscopy on the tegumental topography of P. alaskense. The body wall musculature of P. alaskense has three layers of muscle fibres – the outer circular, intermediate longitudinal and inner diagonal ones. The muscle system elements are well-developed in the attachment organs, digestive and reproductive systems, in the excretory sphincter. Serotonin- and FMRFamide-immunopositive neurons and neurites are found in the head ganglia, circular commissure, longitudinal nerve cords, and in the transversal connective commissures. The innervation of the oral and ventral suckers, pharynx, and the reproductive system compartments by the serotonergic and FMRFamide-immunopositive neurites is revealed. The results are discussed in connection with the published data on the presence and functional roles of the serotonin and FMRFamide-related peptides in Platyhelminthes.The accepted manuscript in pdf format is listed with the files at the bottom of this page. The presentation of the authors' names and (or) special characters in the title of the manuscript may differ slightly between what is listed on this page and what is listed in the pdf file of the accepted manuscript; that in the pdf file of the accepted manuscript is what was submitted by the author

    Light Emitting Devices Based on Quantum Well-Dots

    No full text
    We review epitaxial formation, basic properties, and device applications of a novel type of nanostructures of mixed (0D/2D) dimensionality that we refer to as quantum well-dots (QWDs). QWDs are formed by metalorganic vapor phase epitaxial deposition of 4–16 monolayers of InxGa1−xAs of moderate indium composition (0.3 < x < 0.5) on GaAs substrates and represent dense arrays of carrier localizing indium-rich regions inside In-depleted residual quantum wells. QWDs are intermediate in properties between 2D quantum wells and 0D quantum dots and show some advantages of both of those. In particular, they offer high optical gain/absorption coefficients as well as reduced carrier diffusion in the plane of the active region. Edge-emitting QWD lasers demonstrate low internal loss of 0.7 cm−1 and high internal quantum efficiency of 87%. as well as a reasonably high level of continuous wave (CW) power at room temperature. Due to the high optical gain and suppressed non-radiative recombination at processed sidewalls, QWDs are especially advantageous for microlasers. Thirty-one μm in diameter microdisk lasers show a high record for this type of devices output power of 18 mW. The CW lasing is observed up to 110 °C. A maximum 3-dB modulation bandwidth of 6.7 GHz is measured in the 23 μm in diameter microdisks operating uncooled without a heatsink. The open eye diagram is observed up to 12.5 Gbit/s, and error-free 10 Gbit/s data transmission at 30 °C without using an external optical amplifier, and temperature stabilization is demonstrated

    Apixaban versus warfarin in patients with atrial fibrillation

    No full text
    BACKGROUND: Vitamin K antagonists are highly effective in preventing stroke in patients with atrial fibrillation but have several limitations. Apixaban is a novel oral direct factor Xa inhibitor that has been shown to reduce the risk of stroke in a similar population in comparison with aspirin. METHODS: In this randomized, double-blind trial, we compared apixaban (at a dose of 5 mg twice daily) with warfarin (target international normalized ratio, 2.0 to 3.0) in 18,201 patients with atrial fibrillation and at least one additional risk factor for stroke. The primary outcome was ischemic or hemorrhagic stroke or systemic embolism. The trial was designed to test for noninferiority, with key secondary objectives of testing for superiority with respect to the primary outcome and to the rates of major bleeding and death from any cause. RESULTS: The median duration of follow-up was 1.8 years. The rate of the primary outcome was 1.27% per year in the apixaban group, as compared with 1.60% per year in the warfarin group (hazard ratio with apixaban, 0.79; 95% confidence interval [CI], 0.66 to 0.95; P<0.001 for noninferiority; P = 0.01 for superiority). The rate of major bleeding was 2.13% per year in the apixaban group, as compared with 3.09% per year in the warfarin group (hazard ratio, 0.69; 95% CI, 0.60 to 0.80; P<0.001), and the rates of death from any cause were 3.52% and 3.94%, respectively (hazard ratio, 0.89; 95% CI, 0.80 to 0.99; P = 0.047). The rate of hemorrhagic stroke was 0.24% per year in the apixaban group, as compared with 0.47% per year in the warfarin group (hazard ratio, 0.51; 95% CI, 0.35 to 0.75; P<0.001), and the rate of ischemic or uncertain type of stroke was 0.97% per year in the apixaban group and 1.05% per year in the warfarin group (hazard ratio, 0.92; 95% CI, 0.74 to 1.13; P = 0.42). CONCLUSIONS: In patients with atrial fibrillation, apixaban was superior to warfarin in preventing stroke or systemic embolism, caused less bleeding, and resulted in lower mortality. Copyright © 2011 Massachusetts Medical Society. All rights reserved

    Apixaban compared with warfarin in patients with atrial fibrillation and previous stroke or transient ischaemic attack: A subgroup analysis of the ARISTOTLE trial

    No full text
    Background: In the ARISTOTLE trial, the rate of stroke or systemic embolism was reduced by apixaban compared with warfarin in patients with atrial fibrillation (AF). Patients with AF and previous stroke or transient ischaemic attack (TIA) have a high risk of stroke. We therefore aimed to assess the efficacy and safety of apixaban compared with warfarin in prespecified subgroups of patients with and without previous stroke or TIA. Methods: Between Dec 19, 2006, and April 2, 2010, patients were enrolled in the ARISTOTLE trial at 1034 clinical sites in 39 countries. 18 201 patients with AF or atrial flutter were randomly assigned to receive apixaban 5 mg twice daily or warfarin (target international normalised ratio 2·0-3·0). The median duration of follow-up was 1·8 years (IQR 1·4-2·3). The primary efficacy outcome was stroke or systemic embolism, analysed by intention to treat. The primary safety outcome was major bleeding in the on-treatment population. All participants, investigators, and sponsors were masked to treatment assignments. In this subgroup analysis, we estimated event rates and used Cox models to compare outcomes in patients with and without previous stroke or TIA. The ARISTOTLE trial is registered with ClinicalTrials.gov, number NTC00412984. Findings: Of the trial population, 3436 (19%) had a previous stroke or TIA. In the subgroup of patients with previous stroke or TIA, the rate of stroke or systemic embolism was 2·46 per 100 patient-years of follow-up in the apixaban group and 3·24 in the warfarin group (hazard ratio [HR] 0·76, 95% CI 0·56 to 1·03); in the subgroup of patients without previous stroke or TIA, the rate of stroke or systemic embolism was 1·01 per 100 patient-years of follow-up with apixaban and 1·23 with warfarin (HR 0·82, 95% CI 0·65 to 1·03; p for interaction=0·71). The absolute reduction in the rate of stroke and systemic embolism with apixaban versus warfarin was 0·77 per 100 patient-years of follow-up (95% CI -0·08 to 1·63) in patients with and 0·22 (-0·03 to 0·47) in those without previous stroke or TIA. The difference in major bleeding with apixaban compared with warfarin was 1·07 per 100 patient-years (95% CI 0·09-2·04) in patients with and 0·93 (0·54-1·32) in those without previous stroke or TIA. Interpretation: The effects of apixaban versus warfarin were consistent in patients with AF with and without previous stroke or TIA. Owing to the higher risk of these outcomes in patients with previous stroke or TIA, the absolute benefits of apixaban might be greater in this population. Funding: Bristol-Myers Squibb and Pfizer. © 2012 Elsevier Ltd

    Measurements of long-range two-particle correlation over a wide pseudorapidity range in p–Pb collisions at √sNN = 5.02 TeV

    No full text
    Correlations in azimuthal angle extending over a long range in pseudorapidity between particles, usually called the "ridge" phenomenon, were discovered in heavy-ion collisions, and later found in pp and p−Pb collisions. In large systems, they are thought to arise from the expansion (collective flow) of the produced particles. Extending these measurements over a wider range in pseudorapidity and final-state particle multiplicity is important to understand better the origin of these long-range correlations in small-collision systems. In this Letter, measurements of the long-range correlations in p−Pb collisions at sNN−−−√=5.02 TeV are extended to a pseudorapidity gap of Δη∼8 between particles using the ALICE, forward multiplicity detectors. After suppressing non-flow correlations, e.g., from jet and resonance decays, the ridge structure is observed to persist up to a very large gap of Δη∼8 for the first time in p−Pb collisions. This shows that the collective flow-like correlations extend over an extensive pseudorapidity range also in small-collision systems such as p−Pb collisions. The pseudorapidity dependence of the second-order anisotropic flow coefficient, v2({\eta}), is extracted from the long-range correlations. The v2(η) results are presented for a wide pseudorapidity range of −3.1<η<4.8 in various centrality classes in p−Pb collisions. To gain a comprehensive understanding of the source of anisotropic flow in small-collision systems, the v2(η) measurements are compared to hydrodynamic and transport model calculations. The comparison suggests that the final-state interactions play a dominant role in developing the anisotropic flow in small-collision systems

    Multiplicity and event-scale dependent flow and jet fragmentation in pp collisions at √s = 13 TeV and in p–Pb collisions at √sNN = 5.02 TeV

    No full text
    Long- and short-range correlations for pairs of charged particles are studied via two-particle angular correlations in pp collisions at s√=13 TeV and p−Pb collisions at sNN−−−√=5.02 TeV. The correlation functions are measured as a function of relative azimuthal angle Δφ and pseudorapidity separation Δη for pairs of primary charged particles within the pseudorapidity interval |η|<0.9 and the transverse-momentum interval 1<pT<4 GeV/c. Flow coefficients are extracted for the long-range correlations (1.6<|Δη|<1.8) in various high-multiplicity event classes using the low-multiplicity template fit method. The method is used to subtract the enhanced yield of away-side jet fragments in high-multiplicity events. These results show decreasing flow signals toward lower multiplicity events. Furthermore, the flow coefficients for events with hard probes, such as jets or leading particles, do not exhibit any significant changes compared to those obtained from high-multiplicity events without any specific event selection criteria. The results are compared with hydrodynamic-model calculations, and it is found that a better understanding of the initial conditions is necessary to describe the results, particularly for low-multiplicity events
    corecore