24 research outputs found

    Clamidiosi felina: indagine epidemiologica.

    No full text

    Febbre Q nella pecora: diagnosi sperimentale.

    No full text

    Development and preliminary validation of a pain scale for ophthalmic pain in horses: The Equine Ophthalmic Pain Scale (EOPS)

    No full text
    The purpose of this study was to describe the development and preliminary validation of a composite pain scale, called the Equine Ophthalmic Pain Scale (EOPS), to assess ocular pain in horses. Indicators associated with ocular pain were selected and classified as behavioural, physiological or ocular expressions. Eight horses diagnosed with ocular or adnexa diseases that required medical or surgical treatment were enrolled in the study (group P). The developed EOPS was applied at the baseline (T0) and 1 week later (T7). Moreover, the EOPS was applied twice, 1 week apart, to 15 healthy control horses (group C). Videos of 60-80 s duration of all assessments were retrospectively analysed by seven masked observers, who scored items included in the behavioural and ocular expression categories of the EOPS.The inter- and intra-observer reliability was excellent (intraclass correlation coefficients >0.75) for most of the scored items. Cronbach's alpha (0.76) indicated that the EOPS had good internal consistency. The total score (TS), calculated as the sum of all scores, differed between groups C and P at TO (P < 0.001) and reduced after medical/surgical treatment in group P (P = 0.017), indicating the responsiveness of the EOPS. Moreover, the area under the curve (AUC=0.918, 95% confidence interval = 0.815-1.000; P < 0.001) indicated that the EOPS was very accurate for distinguishing healthy from pathological animals. Sensitivity and specificity of EOPS to identify horses with ocular pathology (at the optimal cut-off, i.e. TS >= 7) were 81.3% and 100.0%, respectively. However, 'overall behaviour', 'position inside the box', 'ear movements' and 'head position' items as well as physiological parameters, showed sub-optimal reliability, consistency and/or item-total correlation, suggesting that there is still mom to improve this composite scale

    Use of experimental chicks model for paratuberculosis enteritis (Johne's Diseases)

    No full text

    Comparison of Mesh and Barbed Suture for Laparoscopic Nephrosplenic Space Ablation in Horses

    No full text
    Nephrosplenic space (NSS) ablation has been demonstrated to be an effective technique for prevention of left dorsal displacement of the large colon and multiple laparoscopic techniques, among which ablation with mesh or with a barbed suture, have been proposed. Our objective was to compare two laparoscopic techniques for closure of the NSS in twenty-eight horses diagnosed with nephrosplenic entrapment. Medical records of horses that had laparoscopic NSS ablation in two referral centers between 2017–2019 were retrieved. Duration of surgery, complications, and short- and long-term follow-up information were collected and compared. Costs were also calculated and compared. All horses met the inclusion criteria: 9 had NSS ablation with a mesh implant (group M), 19 with barbed suture material (group B). One horse in group B had recurrent colic after discharge. At control laparoscopy after 5 months, the NSS resulted in still not being ablated because of a failure of the suture. In group M, three horses had recurrent colic. One was successfully treated medically, one died of unknown causes and the third required a second laparoscopic suturing at 3–6 months because of failure of the mesh implant. The mean time of surgery and costs were lower in group B compared to group M. The barbed suture technique was faster, more cost-effective and had a lower complication rate than the mesh implant

    Ureteral Endoscopy to Detect Upper Urinary Tract Diseases in Horses

    No full text
    Ureteral endoscopy is a routine procedure in human medicine, whereas the reports of this procedure on horses are few and far between. The aim of this paper is to describe the endoscopic technique to evaluate the ureters in standing, sedated horses. An endoscopy of the ureters and lower urinary tract was performed using flexible endoscopes on 4 horses, three mares and one gelding. The animals were sedated with alpha-2-agonists and an epidural anaesthesia was given. An endoscopy of the ureter in the horse is easy to perform, causes the animal no adverse effects and could provide significant information on the diagnosis and prognosis of diseases of the urinary tract

    Long-term safety and tolerance of silicone and self-expandable airway stents: an experimental study

    No full text
    BACKGROUND: A variety of respiratory stents are currently available, but the ideal airway prosthesis seems far from being recognized. The objective of this study was to verify safety and long-term effect on the bronchial wall of three different types of airway stents. METHODS: Twelve healthy adult sheep were divided in three groups, scheduled to receive: (1) bare self-expandable metallic stents (Gianturco); (2) silicone stents (Dumon); and (3) covered self-expandable synthetic stents (Polyflex). Insertions were performed through a rigid bronchoscope under general anesthesia. Chest roentgenogram was performed 1 and 6 months after surgery, and flexible bronchoscopy after 6 months. Twelve months postoperatively, the animals were killed and a postmortem examination was carried out. RESULTS: All Polyflex stents migrated during the observation period; one late migration was observed in the Dumon group. Microscopic study showed: (1) Gianturco stents: full-thickness perforation of the bronchial wall covered by a thick layer of a chronic inflammatory infiltrate. Infection by Candida at the bottom of some ulcerations; (2) Dumon stents: mild bronchial inflammation (squamous metaplasia, submucosal inflammatory infiltrates; granuloma-like infiltrates). In case of displacement, no significant changes of the previously stented bronchus occurred; and (3) Polyflex stents: no changes of the previously stented bronchi. CONCLUSIONS: Gianturco stents proved unsafe in the long term, owing to the risk of severe airway wall damage. The Polyflex stent is well tolerated but presents a high migration rate. Silicone stents show several limitations but appear to be well tolerated by the host mucosa

    Long-term safety and tolerance of silicone and self-expandable airway stents: an experimental study.

    No full text
    corecore