276 research outputs found

    A paperfluidic platform to detect Neisseria gonorrhoeae in clinical samples

    Full text link
    Globally, the microbe Neisseria gonorrhoeae (NG) causes 106 million newly documented sexually transmitted infections each year. Once appropriately diagnosed, NG infections can be readily treated with antibiotics, but high-risk patients often do not return to the clinic for treatment if results are not provided at the point of care. A rapid, sensitive molecular diagnostic would help increase NG treatment and reduce the prevalence of this sexually transmitted disease. Here, we report on the design and development of a rapid, highly sensitive, paperfluidic device for point-of-care diagnosis of NG. The device integrates patient swab sample lysis, nucleic acid extraction, thermophilic helicase-dependent amplification (tHDA), an internal amplification control (NGIC), and visual lateral flow detection within an 80 min run time. Limits of NG detection for the NG/NGIC multiplex tHDA assay were determined within the device, and clinical performance was validated retroactively against qPCR-quantified patient samples in a proof-of-concept study. This paperfluidic diagnostic has a clinically relevant limit of detection of 500 NG cells per device with analytical sensitivity down to 10 NG cells per device. In triplicate testing of 40 total urethral and vaginal swab samples, the device had 95% overall sensitivity and 100% specificity, approaching current laboratory-based molecular NG diagnostics. This diagnostic platform could increase access to accurate NG diagnoses to those most in need.This work was funded by the National Institute of Health National Institute of Allergy and Infectious Diseases award number R01 AI113927 to Boston University and the NIH National Institute of Biomedical and Bioengineering award number U54 EB007958 to Johns Hopkins University. (R01 AI113927 - National Institute of Health National Institute of Allergy and Infectious Diseases; U54 EB007958 - NIH National Institute of Biomedical and Bioengineering)Accepted manuscrip

    Antiviral Prescriptions to U.S. Ambulatory Care Visits with a Diagnosis of Influenza before and after High Level of Adamantane Resistance 2005–06 Season

    Get PDF
    Rapid emergence of influenza A viruses resistance to anti-influenza drugs has been observed in the past five years. Our objective was to compare antiviral prescription patterns of ambulatory care providers to patients with a diagnosis of influenza before and after the 2005-2006 influenza season, which was temporally concordant with the emergence of adamantane resistance. We also determined providers' adherence to Centers for Disease Control and Prevention (CDC) 2006 interim treatment guidelines for influenza after the dissemination of guidelines.We conducted a multi-year cross-sectional analysis using 2002-2006 data from the national representative ambulatory care surveys, National Ambulatory Medical Care Survey and National Hospital Ambulatory Medical Care Survey. Our main outcome measure was prescription of any anti-influenza pharmaceutical medication, including amantadine, rimantadine, oseltamivir, and zanamivir. Analyses were performed using procedures taking into account the multi-stage survey design and weighted sampling probabilities of the data source. Overall, there were 941 visits to U.S. ambulatory care providers for which the diagnosis of influenza was made, representing 12,140,727 visits nationally. Antiviral drugs were prescribed in 21.7% of visits. Even though prescription rates were not significantly different by influenza season (2001-02: 26.4%; 2002-03: 11.2%; 2003-04: 16.5%; 2004-05: 18.0%; 2005-06: 35.8%; 2006-07: 46.5%, p = 0.061), significantly higher prescription rates were observed in the high adamantane resistance period (18.7% versus 37.0%, p = 0.023), and after the announcement of the 2006 guidelines (18.5% versus 38.8%, p = 0.032). Use of adamantanes decreased over time, in that they were commonly used during influenza seasons 2001-03 (60.1%), but used much less frequently during seasons 2003-05 (31.9%), and used rarely after high adamantane resistance emerged (2.2%) (p<0.001). Adherence to 2006 guidelines was 97.7%. After March 2006, no prescriptions for adamantanes were given to patients with a diagnosis of influenza.In this nationally representative study of U.S. ambulatory care visits, we found a complete absence of the use of adamantanes in all ambulatory care settings after March 2006, closely corresponding to release of the 2006 CDC interim guidelines. Adherence to such practice is an essential element for control and prevention of influenza, especially during the era of emergence of resistance to anti-viral drugs

    Rapid and point-of-care tests for the diagnosis of Trichomonas vaginalis in women and men.

    Get PDF
    BACKGROUND: Trichomonasvaginalis (TV) is a highly prevalent parasitic infection worldwide. It is associated with many adverse reproductive health outcomes. Many infections are asymptomatic and syndromic management leads to underdetection of TV. Traditional methods of TV detection such as wet preparation are insensitive. New rapid, point-of-care (POC) tests can enhance the diagnosis of trichomoniasis. METHODS: The authors reviewed the literature and discuss older POC tests for TV detection, as well as the OSOM lateral flow test, the AmpliVue test, the Solana test and the GeneXpert test as well as the limitations of wet preparation and culture for detection of TV. RESULTS: The OSOM test is easy to perform, compared with other POC tests, and is Clinical Laboratory Improvement Amendments (CLIA)-waived, equipment-free, has sensitivities of 83%-86% compared with nucleic acid amplification tests (NAATs) and can be performed in 15 min. The AmpliVue and the Solana tests are not CLIA waived and require small pieces of equipment. They are molecular amplified assays and can be completed in <1 hour. AmpliVue demonstrated a sensitivity for vaginal swabs of 100% compared with wet preparation/culture and 90.7% compared with NAATs. Solana demonstrated a sensitivity of 98.6%-100% for vaginal swabs and 92.9%-98% for female urines, compared with wet preparation/culture. Compared with other NAATs, the sensitivity for Solana was 89.7% for swabs and 100% for urine. The GeneXpert TV test for women and men is a moderately complex test, requires a small platform and can be performed in <1 hour. The sensitivity compared with wet preparation/culture for self-collected vaginal swabs was 96.4%, 98.9% for endocervical specimens and 98.4% for female urine. For men, sensitivity for urines was excellent (97.2%). The specificity for all assays was excellent. CONCLUSIONS: Several rapid POC tests have the potential to rapidly diagnose trichomoniasis in women and one is available for detection of TV in men

    Quantification of HIV-1 RNA Among Men Who Have Sex With Men Using an At-Home Self-Collected Dried Blood Spot Specimen: Feasibility Study

    Full text link
    Background: Suboptimal antiretroviral therapy (ART) adherence and disengagement in care present significant public health challenges because of the increased probability of HIV transmission. In the United States, men who have sex with men (MSM) continue to be disproportionately affected by HIV, highlighting a critical need to engage high-risk MSM living with HIV who are not engaged or retained in care. Objective: The aim of the study was to assess the feasibility of at-home blood self-collection and laboratory quantification of HIV-1 RNA viral load (VL) to report laboratory-based VL outcomes and compare self-reported and laboratory-reported VL Methods: Between 2016 and 2017, 766 US HIV-positive MSM enrolled in a Web-based behavioral intervention were invited to participate in an at-home dried blood spot (DBS) collection study using HemaSpot-HF kits (Spot On Sciences, Inc, Austin, TX) for laboratory-quantified VL. Results: Of those invited to participate, 72.3% (554/766) enrolled in the DBS study. Most (79.2%, 439/554) men enrolled reported attempting to collect their blood, 75.5% (418/554) of participants mailed a DBS specimen to the research laboratory, and 60.8% (337/554) had an adequate blood sample for VL testing. Of the 337 specimens tested for VL by the laboratory, 52.5% (177/337) had detectable VL (median: 3508 copies/mL; range: 851-1,202,265 copies/mL). Most men (83.9%, 135/161) who returned a DBS specimen with laboratory-quantified detectable VL self-reported an undetectable VL during their last clinical visit. Conclusions: Home collection of DBS samples from HIV-positive MSM is feasible and has the potential to support clinical VL monitoring. Discrepant laboratory HIV-1 RNA values and self-reported VL indicate a need to address perceived VL status, especially in the era of treatment as prevention. Most participants were willing to use an at-home DBS kit in the future, signaling an opportunity to engage high-risk MSM in long-term HIV care activities

    Accurate PCR detection of influenza A/B and respiratory syncytial viruses by use of Cepheid Xpert Flu+RSV Xpress Assay in point-of-care settings: Comparison to Prodesse ProFlu+

    Get PDF
    ABSTRACT The Xpert Flu+RSV Xpress Assay is a fast, automated in vitro diagnostic test for qualitative detection and differentiation of influenza A and B viruses and respiratory syncytial virus (RSV) performed on the Cepheid GeneXpert Xpress System. The objective of this study was to establish performance characteristics of the Xpert Flu+RSV Xpress Assay compared to those of the Prodesse ProFlu+ real-time reverse transcription-PCR (RT-PCR) assay (ProFlu+) for the detection of influenza A and B viruses as well as RSV in a Clinical Laboratory Improvement Amendments (CLIA)-waived (CW) setting. Overall, the assay, using fresh and frozen nasopharyngeal (NP) swabs, demonstrated high concordance with results of the ProFlu+ assay in the combined CW and non-CW settings with positive percent agreements (PPA) (100%, 100%, and 97.1%) and negative percent agreements (NPA) (95.2%, 99.5%, and 99.6%) for influenza A and B viruses and RSV, respectively. In conclusion, this multicenter study using the Cepheid Xpert Flu+RSV Xpress Assay demonstrated high sensitivities and specificities for influenza A and B viruses and RSV in ∼60 min for use at the point-of-care in the CW setting. </jats:p

    Perceptions of an Ideal Point-of-Care Test for Sexually Transmitted Infections – A Qualitative Study of Focus Group Discussions with Medical Providers

    Get PDF
    A point-of-care test (POCT) for sexually transmitted infections (STIs), which offers immediate diagnosis resulting in patients receiving diagnosis and treatment in a single visit, has the ability to address some of the STI control needs. However, needs assessment from STI experts and end users about currently available STI POCTs and their future new development has not been evaluated since World Health Organization Sexually Transmitted Diseases Diagnostics Initiative was formed over 15 years ago. Therefore, our objective was to explore the perceptions of the ideal types of STI POCT for use in health care settings.A qualitative study, encompassing eight focus groups, was conducted from March 2008 through April 2009. Participants included 6 STD clinic directors, 63 clinicians, and 7 public health/laboratory/epidemiology professionals in the STI field. Discussion topics included currently available POCT, perceived barriers to using POCT in clinics, priority STI for the development of new POCT, and characteristics of the ideal POCT. All discussions were recorded and transcribed verbatim. Themes raised as barriers for current POCT included complexity, long time frames of the so-called "rapid" test, multiple time-driven steps, requiring laboratory technician, difficulty in reading result, interruption of workflow, unreliability, and invasiveness. Chlamydia trachomatis was identified as the priority organism for development of a new STI POCT. Themes indicated for the ideal POCT included rapid turnaround (up to 20 minutes), ease of use, non-invasive, accurate (preferred sensitivity and specificity in the range of high 90s), Clinical Laboratory Improvement Amendments (CLIA)-waived, user-friendly (for both patients and staff), compact, durable, and sturdy.Focus group discussions with STI experts and professionals highlighted chlamydia as the top priority pathogen for POCT development, and identified the qualities of new POCT for STIs. Participants endorsed ease of use, rapid turnaround and high accuracy as essential characteristics of an ideal POCT

    A meta-analysis of point-of-care laboratory tests in the diagnosis of novel 2009 swine-lineage pandemic influenza A (H1N1)

    Get PDF
    Abstract This paper reviews 14 published studies describing performance characteristics, including sensitivity and specificity, of commercially available rapid, point-of-care (POC) influenza tests in patients affected by an outbreak of a novel swine-related influenza A (H1N1) that was declared a pandemic in 2009. Although these POC tests were not intended to be specific for this pandemic influenza strain, the nonspecialized skills required and the timeliness of results make these POC tests potentially valuable for clinical and public health use. Pooled sensitivity and specificity for the POC tests studied were 68% and 81%, respectively, but published values were not homogeneous with sensitivities and specificities ranging from 10% to 88% and 51% to 100%, respectively. Pooled positive and negative likelihood ratios were 5.94 and 0.42, respectively. These results support current recommendations for use of rapid POC tests when H1N1 is suspected, recognizing that positive results are more reliable than negative results in determining infection, especially when disease prevalence is high

    Herpes Simplex Virus Type 2 Seroprevalence and Ultrasound-Diagnosed Uterine Fibroids in a Large Population of Young African-American Women

    Get PDF
    For decades reproductive tract infections (RTIs) have been hypothesized to play a role in uterine fibroid development. The few previous studies conducted used self-reported history of RTIs and had inconsistent findings. We investigated this hypothesis further using serological analysis, an immunological measure of past exposure. We focused on herpes simplex virus type 2 (HSV-2) because prior published data have suggested a possible association with fibroids, and serology for HSV-2 is much more sensitive than self-report. We used cross-sectional enrollment data from African-American women enrolled in a prospective study of fibroid incidence and growth (recruited 2010–2012) in the Detroit, Michigan, area. The women were aged 23–34 years and were screened for fibroids using a standardized ultrasound examination at their enrollment. Age- and multivariable-adjusted logistic regression models were used to estimate odds ratios. Of 1,696 participants, 1,658 had blood samples and HSV-2 serology results; 22% of participants with serology results had fibroids. There was no significant association between HSV-2 seropositivity and the presence of fibroids (multivariable-adjusted odds ratio = 0.94, 95% confidence interval: 0.73, 1.20), nor were there any associations with size of the largest fibroid, number of fibroids, or total fibroid volume. Our data provide no evidence for an influence of HSV-2 exposure on fibroid risk in young African-American women. Further study of other serologically measured RTIs is warranted

    Rapid Diagnosis of Trichomonas vaginalis by Testing Vaginal Swabs in an Isothermal Helicase-Dependent AmpliVue Assay

    Get PDF
    The AmpliVue™ Trichomonas Assay (Quidel) is a new FDA cleared rapid test for qualitative detection of Trichomonas vaginalis (TV) DNA in female vaginal specimens. The assay is based on BioHelix’s Helicase-Dependent Amplification (HDA) isothermal technology in conjunction with a disposable lateral-flow detection device, with a total turn-around time of approximately 45 minutes

    The Respiratory Protection Effectiveness Clinical Trial (ResPECT): a cluster-randomized comparison of respirator and medical mask effectiveness against respiratory infections in healthcare personnel.

    Get PDF
    BACKGROUND: Although N95 filtering facepiece respirators and medical masks are commonly used for protection against respiratory infections in healthcare settings, more clinical evidence is needed to understand the optimal settings and exposure circumstances for healthcare personnel to use these devices. A lack of clinically germane research has led to equivocal, and occasionally conflicting, healthcare respiratory protection recommendations from public health organizations, professional societies, and experts. METHODS: The Respiratory Protection Effectiveness Clinical Trial (ResPECT) is a prospective comparison of respiratory protective equipment to be conducted at multiple U.S. study sites. Healthcare personnel who work in outpatient settings will be cluster-randomized to wear N95 respirators or medical masks for protection against infections during respiratory virus season. Outcome measures will include laboratory-confirmed viral respiratory infections, acute respiratory illness, and influenza-like illness. Participant exposures to patients, coworkers, and others with symptoms and signs of respiratory infection, both within and beyond the workplace, will be recorded in daily diaries. Adherence to study protocols will be monitored by the study team. DISCUSSION: ResPECT is designed to better understand the extent to which N95s and MMs reduce clinical illness among healthcare personnel. A fully successful study would produce clinically relevant results that help clinician-leaders make reasoned decisions about protection of healthcare personnel against occupationally acquired respiratory infections and prevention of spread within healthcare systems. TRIAL REGISTRATION: The trial is registered at clinicaltrials.gov, number NCT01249625 (11/29/2010)
    • …
    corecore