629 research outputs found

    Local Heat Transfer Coefficients Under Flows Induced by Vibrating Cantilevers

    Get PDF

    Confined Jet Impingement with Boiling on a Variety of Enhanced Surfaces

    Get PDF
    Confined jet impingement with boiling offers unique and attractive performance characteristics for thermal management of high heat flux components. Two-phase operation of jet impingement has been shown to provide high heat transfer coefficients while maintaining a uniform temperature over a target surface. This can be achieved with minimal increases in pumping power compared to single-phase operation. To investigate further enhancements in heat transfer coefficients and increases in the maximum heat flux supported by two-phase jet impingement, an experimental study of surface enhancements is performed using the dielectric working fluid HFE-7100. The performance of a single, 3.75 mm-diameter jet orifice is compared across four distinct copper target surfaces of varying enhancement scales: a baseline smooth flat surface, a flat surface coated with a microporous layer, a surface with macroscale area enhancement (extended square pin fins), and a hybrid surface on which the pin fins are coated with the microporous layer. The heat transfer performance of each surface is compared in single- and two-phase operation at three volumetric flow rates (450 ml/min, 900 ml/min, and 1800 ml/min); area-averaged heat transfer parameters and pressure drop are reported. The mechanisms resulting in enhanced performance for the different surfaces are identified, with a special focus on the coated pin fins. This hybrid surface showed the best enhancement of all those tested, and resulted in an extension of critical heat flux (CHF) by a maximum of 2.42 times compared to the smooth flat surface at the lowest flow rate investigated; no increase in the overall pressure drop was measured

    Latent-Heat Augmentation of Thermocline Energy Storage for Concentrating Solar Power – A System-Level Assessment

    Get PDF
    Molten-salt thermocline tanks are a low-cost energy storage option for concentrating solar power plants. Despite the potential economic advantage, the capacity of thermocline tanks to store sufficient amounts of high-temperature heat is limited by the low energy density of the constituent sensible-heat storage media. A promising design modification replaces conventional rock filler inside the tank with an encapsulated phase-change material (PCM), contributing a latent heat storage mechanism to increase the overall energy density. The current study presents a new finite-volume approach to simulate mass and energy transport inside a latent heat thermocline tank at low computational cost. This storage model is then integrated into a system-level model of a molten-salt power tower plant to inform tank operation with respect to realistic solar collection and power production. With this system model, PCMs with different melting temperatures and heats of fusion are evaluated for their viability in latent heat storage for solar plants. Thermocline tanks filled with a single PCM do not yield a substantial increase in annual storage or plant output over a conventional rock-filled tank of equal size. As the melting temperature and heat of fusion are increased, the ability of the PCM to support steam generation improves but the corresponding ability of the thermocline tank to utilize this available latent heat decreases. This trend results from an inherent deconstruction of the heat-exchange region inside the tank between sensible and latent heat transfer, preventing effective use of the added phase change for daily plant operations. This problem can be circumvented with a cascaded filler structure composed of multiple PCMs with their melting temperatures tuned along the tank height. However, storage benefits with these cascaded tank structures are shown to be highly sensitive to the proper selection of the PCM melting points relative to the thermocline tank operating temperatures

    Cooling Performance of Arrays of Vibrating Cantilevers

    Get PDF
    provide heat transfer enhancement while consuming little power. Past research has focused on feasibility and performance characterization of a single fan, while arrays of such fans, which have important practical applications, have not been widely studied. This paper investigates the heat transfer achieved using arrays of cantilevers vibrating in their first resonant mode. This is accomplished by determining the local convection coefficients due to the two piezoelectric fans mounted near a constant heat flux surface using infrared thermal imaging. The heat transfer performance is quantified over a wide range of operating conditions, including vibration amplitude (7.5–10 mm), distance from heat source (0.01–2 times the fan amplitude), and pitch between fans (0.5–4 times the amplitude). The convection patterns observed are strongly dependent on the fan pitch, with the behavior resembling a single fan for small fan pitch and two isolated fans at a large pitch. The area-averaged thermal performance of the fan array is superior to that of a single fan, and correlations are developed to describe this enhancement in terms of the governing parameters. The best thermal performance is obtained when the fan pitch is 1.5 times its vibration amplitude

    Evaporative Deposition on Superhydrophobic Surfaces

    Get PDF
    Sessile droplets containing colloidal suspensions of latex particles in water are evaporated on temperature‐controlled superhydrophobic surfaces of varying geometry. The transient droplet shape and wetting behavior under evaporation are analyzed as a function of surface temperature and morphology. Throughout the evaporation process, the solid‐liquid interface is characterized by a constant contact radius evaporation mode (CCR), a constant contact angle evaporation mode (CCA), or a mixed mode of both CCR and CCA. The total evaporation time can be significantly reduced via substrate heating as compared to diffusion‐limited evaporation at thermal equilibrium. To describe the spatial distribution of the particle residues left on the surfaces, qualitative and quantitative evaluations of the depositions are presented. The results show that droplet evaporation on superhydrophobic surfaces driven by either diffusion or substrate heating, suppresses particle deposition at the contact line ‐ the so‐called ‘coffee ring effect’ – and signifies the ability to control the location of solute deposits

    Local Heat Transfer Coefficients Induced by Piezoelectrically Actuated Vibrating Cantilevers

    Get PDF
    Piezoelectric fans have been shown to provide substantial enhancements in heat transfer over natural convection while consuming very little power. These devices consist of a piezoelectric material attached to a flexible cantilever beam. When driven at resonance, large oscillations at the cantilever tip cause fluid motion, which in turn results in improved heat transfer rates. In this study, the local heat transfer coefficients induced by piezoelectric fans are determined experimentally for a fan vibrating close to an electrically heated stainless steel foil, and the entire temperature field is observed by means of an infrared camera. Four vibration amplitudes ranging from 6.35 to 10 mm are considered, with the distance from the heat source to the fan tip chosen to vary from 0.01 to 2.0 times the amplitude. The two-dimensional contours of the local heat transfer coefficient transition from a lobed shape at small gaps to an almost circular shape at intermediate gaps. At larger gaps, the heat transfer coefficient distribution becomes elliptical in shape. Correlations developed with appropriate Reynolds and Nusselt number definitions describe the area-averaged thermal performance with a maximum error of less than 12%

    Local Single- and Two-Phase Heat Transfer from an Impinging Cross-Shaped Jet

    Get PDF
    Local single- and two-phase heat transfer distributions are measured under a confined impinging jet issuing from a cross-shaped orifice. Spatially resolved temperature maps and convection coefficients resulting from the impinging flow are obtained via infrared imaging of a thin-foil heat source. The cooling patterns in single- and two-phase operation are explained by an accompanying numerical investigation of the fluid flow issuing from the orifice; computed velocity magnitudes and turbulence intensities are presented. In single-phase operation, the coolest surface temperatures correspond to areas with high liquid velocities. High velocities and developing turbulence are also shown to increase convective heat transfer along the diagonal outflow directions from the impinging jet. During two-phase transport, boiling preferentially begins in regions of low velocity, providing enhanced heat transfer in the areas least affected by the impingement. The cross-shaped orifice achieves local heat transfer coefficients that exceed the stagnation-point value of a circular jet of equivalent open orifice area by up to 1.5 times, while resulting in an increased pressure drop only 1.1 times higher than that of the circular jet

    A Dataset of Fact-Checked Images Shared on WhatsApp During the Brazilian and Indian Elections

    Full text link
    Recently, messaging applications, such as WhatsApp, have been reportedly abused by misinformation campaigns, especially in Brazil and India. A notable form of abuse in WhatsApp relies on several manipulated images and memes containing all kinds of fake stories. In this work, we performed an extensive data collection from a large set of WhatsApp publicly accessible groups and fact-checking agency websites. This paper opens a novel dataset to the research community containing fact-checked fake images shared through WhatsApp for two distinct scenarios known for the spread of fake news on the platform: the 2018 Brazilian elections and the 2019 Indian elections.Comment: 7 pages. This is a preprint version of an accepted paper on ICWSM'20. Please, consider to cite the conference version instead of this on

    Experimental Study of Aerodynamic Damping in Arrays of Vibrating Cantilevers

    Get PDF
    Cantilever structures vibrating in a fluid are encountered in numerous engineering applications. The aerodynamic loading from a fluid can have a large effect on both the resonance frequency and damping, and has been the subject of numerous studies. The aerodynamic loading on a single beam is altered when multiple beams are configured in an array. In such situations, neighboring beams interact through the fluid and their dynamic behavior is modified. In this work, aerodynamic interactions between neighboring cantilever beams operating near their first resonance mode and vibrating at amplitudes comparable to their widths are experimentally explored. The degree to which two beams become coupled through the fluid is found to be sensitive to vibration amplitude and proximity of neighboring components in the array. The cantilever beams considered are slender piezoelectric fans (approximately 6 cm in length), and are caused to vibrate in-phase and out-of-phase at frequencies near their fundamental resonance values. Aerodynamic damping is expressed in terms of the quality factor for two different array configurations and estimated for both in-phase and out-of-phase conditions. The two array configurations considered are for neighboring fans placed face-to-face and edge-to-edge. It is found that the damping is greatly influenced by proximity of neighboring fans and phase difference. For the face-to-face configuration, a reduction in damping is observed for in-phase vibration, while it is greatly increased for out-of-phase vibration; the opposite effect is seen for the edge-to-edge configuration. The resonance frequencies also show a dependence on the phase difference, but these changes are small compared to those observed for damping. Correlations are developed based on the experimental data which can be used to predict the aerodynamic damping in arrays of vibrating cantilevers. The distance at which the beams no longer interact is quantified for both array configurations. Understanding the fluid interactions between neighboring vibrating beams is essential for predicting the dynamic behavior of such arrays and designing them for practical applications

    Thermal Management of a Soft Starter: Transient Thermal Impedance Model and Performance Enhancements using Phase Change Materials

    Get PDF
    Adverse effects of starting-torque transients and high in-rush currents in induction motors are typically mitigated by employing electronically controlled soft starting voltages through silicon-controlled rectifiers (SCRs). However, the heat dissipation in the soft starter must be carefully managed in the design of motor drives. The objective of this study is both to address the heat dissipation in the soft starter by implementing analytical solutions to the heat diffusion equations inside the soft starter, and to investigate the use of a phase change material (PCM) based heat sink for thermal management of the device. The analytical modeling approach is, however, general, and can be applied to the solution of a range of thermal problems in power electronics. The transient analytical thermal model, based on the thermal quadrupole approach, allows a determination of the transient performance of a soft starter by evaluating the thyristor junction temperature. Predictions from the model are first compared to results obtained using a coupled thermal and electricalmodel based on a resistance/capacitance network approach. Experimental results obtained with the soft starter connected to a low-voltage 200 hp induction machine are then used to validate the model. Additionally, the performance improvement resulting from the use of a hybrid heat sink (plate fin heat sink immersed in a PCM) is evaluated and compared to a conventional air-cooled heat sink without a PCM under identical conditions
    corecore