57 research outputs found

    Detection of emphysema progression in alpha 1-antitrypsin deficiency using CT densitometry; Methodological advances

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Computer tomography (CT) densitometry is a potential tool for detecting the progression of emphysema but the optimum methodology is uncertain. The level of inspiration affects reproducibility but the ability to adjust for this variable is facilitated by whole lung scanning methods. However, emphysema is frequently localised to sub-regions of the lung and targeted densitometric sampling may be more informative than whole lung assessment.</p> <p>Methods</p> <p>Emphysema progression over a 2-year interval was assessed in 71 patients (alpha 1-antitrypsin deficiency with PiZ phenotype) with CT densitometry, using the 15<sup>th </sup>percentile point (Perc15) and voxel index (VI) -950 Hounsfield Units (HU) and -910 HU (VI -950 and -910) on whole lung, limited single slices, and apical, central and basal thirds. The relationship between whole lung densitometric progression (ΔCT) and change in CT-derived lung volume (ΔCT<sub>Vol</sub>) was characterised, and adjustment for lung volume using statistical modelling was evaluated.</p> <p>Results</p> <p>CT densitometric progression was statistically significant for all methods. ΔCT correlated with ΔCT<sub>Vol </sub>and linear regression indicated that nearly one half of lung density loss was secondary to apparent hyperinflation. The most accurate measure was obtained using a random coefficient model to adjust for lung volume and the greatest progression was detected by targeted sampling of the middle third of the lung.</p> <p>Conclusion</p> <p>Progressive hyperinflation may contribute significantly to loss of lung density, but volume effects and absolute tissue loss can be identified by statistical modelling. Targeted sampling of the middle lung region using Perc15 appears to be the most robust measure of emphysema progression.</p

    ApoSense: a novel technology for functional molecular imaging of cell death in models of acute renal tubular necrosis

    Get PDF
    Purpose: Acute renal tubular necrosis (ATN), a common cause of acute renal failure, is a dynamic, rapidly evolving clinical condition associated with apoptotic and necrotic tubular cell death. Its early identification is critical, but current detection methods relying upon clinical assessment, such as kidney biopsy and functional assays, are insufficient. We have developed a family of small molecule compounds, ApoSense, that is capable, upon systemic administration, of selectively targeting and accumulating within apoptotic/necrotic cells and is suitable for attachment of different markers for clinical imaging. The purpose of this study was to test the applicability of these molecules as a diagnostic imaging agent for the detection of renal tubular cell injury following renal ischemia. Methods: Using both fluorescent and radiolabeled derivatives of one of the ApoSense compounds, didansyl cystine, we evaluated cell death in three experimental, clinically relevant animal models of ATN: renal ischemia/reperfusion, radiocontrast-induced distal tubular necrosis, and cecal ligature and perforation-induced sepsis. Results: ApoSense showed high sensitivity and specificity in targeting injured renal tubular epithelial cells in vivo in all three models used. Uptake of ApoSense in the ischemic kidney was higher than in the non-ischemic one, and the specificity of ApoSense targeting was demonstrated by its localization to regions of apoptotic/necrotic cell death, detected morphologically and by TUNEL staining. Conclusion: ApoSense technology should have significant clinical utility for real-time, noninvasive detection of renal parenchymal damage of various types and evaluation of its distribution and magnitude; it may facilitate the assessment of efficacy of therapeutic interventions in a broad spectrum of disease states

    Development and Evaluation of a Novel 99mTc-Labeled Annexin A5 for Early Detection of Response to Chemotherapy

    Get PDF
    99mTc-HYNIC-annexin A5 can be considered as a benchmark in the field of apoptosis imaging. However, 99mTc-HYNIC-annexin A5 has characteristics of high uptake and long retention in non-target tissues such as kidney and liver. To minimize this problem, we developed a novel 99mTc-labeled annexin A5 using a bis(hydroxamamide) derivative [C3(BHam)2] as a bifunctional chelating agent, and evaluated its usefulness as an imaging agent for detecting apoptosis. The amino group of C3(BHam)2 was converted to a maleimide group, and was coupled to thiol groups of annexin A5 pretreated with 2-iminothiolane. 99mTc labeling was performed by a ligand exchange reaction with 99mTc-glucoheptonate. Biodistribution experiments for both 99mTc-C3(BHam)2-annexin A5 and 99mTc-HYNIC-annexin A5 were performed in normal mice. In addition, in tumor-bearing mice, the relationship between the therapeutic effects of chemotherapy (5-FU) and the tumor accumulation of 99mTc-C 3(BHam)2-annexin A5 just after the first treatment of 5-FU was evaluated. 99mTc-C3(BHam)2-annexin A5 was prepared with a radiochemical purity of over 95%. In biodistribution experiments, 99mTc-C3(BHam)2-annexin A5 had a much lower kidney accumulation of radioactivity than 99mTc-HYNIC- annexin A5. In the organs for metabolism, such as liver and kidney, radioactivity after the injection of 99mTc-HYNIC-annexin A5 was residual for a long time. On the other hand, radioactivity after the injection of 99mTc-C3(BHam)2-annexin A5 gradually decreased. In therapeutic experiments, tumor growth in the mice treated with 5-FU was significantly inhibited. Accumulation of 99mTc-C 3(BHam)2-annexin A5 in tumors significantly increased after 5-FU treatment. The accumulation of radioactivity in tumor correlated positively with the counts of TUNEL-positive cells. These findings suggest that 99mTc-C3(BHam)2-annexin A5 may contribute to the efficient detection of apoptotic tumor response after chemotherapy
    • …
    corecore