65 research outputs found

    Comparison of two arthroscopic pump systems based on image quality

    Get PDF
    The effectiveness of arthroscopic pump systems has been investigated with either subjective measures or measures that were unrelated to the image quality. The goal of this study is to determine the performance of an automated pump in comparison to a gravity pump based on objective assessment of the quality of the arthroscopic view. Ten arthroscopic operations performed with a gravity pump and ten performed with an automated pump (FMS Duo system) were matched on duration of the surgery and shaver usage, type of operation, and surgical experience. Quality of the view was defined by means of the presence or absence of previously described definitions of disturbances (bleeding, turbidity, air bubbles, and loose fibrous tissue). The percentage of disturbances for all operations was assessed with a time-disturbance analysis of the recorded operations. The Mann–Whitney U test shows a significant difference in favor of the automated pump for the presence of turbidity only (Exact Sig. [2*(1-tailed Sig.)] = 0.015). Otherwise, no differences were determined (Exact Sig. [2*(1-tailed Sig.)] > 0.436). A new objective method is successfully applied to assess efficiency of pump systems based on the quality of the arthroscopic view. Important disturbances (bleeding, air bubbles, and loose fibrous tissue) are not reduced by an automated pump used in combination with a tourniquet. The most frequent disturbance turbidity is reduced by around 50%. It is questionable if this result justifies the use of an automated pump for straightforward arthroscopic knee surgeries using a tourniquet

    Probing forces of menisci: what levels are safe for arthroscopic surgery

    Get PDF
    Purpose To facilitate effective learning, feedback on performance during arthroscopic training is essential. Less attention has been paid to feedback on monitoring safe handling of delicate tissues such as meniscus. The goal is to measure in vitro probing forces of menisci and compare them with a theoretical maximum probing force (TMPF). Method Menisci samples of ten cadavers were mounted on force platforms to measure probing forces up to 20 N in three directions. Nineteen subjects participated: six novices (experience 60 arthroscopies), and three faculty (>250 a year). All had to perform three tasks on each meniscus sample with an arthroscopic probe: push three times on the superior meniscal surface, perform one continuous run on the superior meniscal surface, and push three times on the inferior meniscal surface. The absolute maximum probing force (AMPF) was determined for each condition. A multivariable linear regression analysis was performed to assess the influence of experience on the force magnitude (P < 0.05). AMPFs were compared to the TMPF (estimated to be 8.5 N). Results The AMPF of the push task was on average 2.8 N (standard deviation (SD) of 0.8 N), of the continuous run task 2.5 N (SD 0.9 N), and of the pull task 3.9 N (SD 2.0 N). Significant difference was present between experts and novices (P < 0.05). The AMPFs are in the same order of magnitude as the TMPF. Conclusion The results indicate the necessity of using a safety level for tissue manipulation when training arthroscopy and a value for is magnitude.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin

    Design and Preliminary Evaluation of a Stiff Steerable Cutter for Arthroscopic Procedures

    Get PDF
    This article describes a novel and simple shaft actuated tip articulation (SATA) mechanism that allows arthroscopic instruments to articulate while remaining stiff. Since the SATA mechanism requires only independent rotation of two tubes for hinge articulation, cables, gears, or other internal components that are normally found in steerable endoscopic instruments become obsolete. The SATA mechanism was integrated in a new steerable cutter prototype and tested. Early user, mechanical strength and cadaver experiments were performed that indicate that this first prototype withstands an axial and sideways force of 100 N and 20 N, that trained users can (dis)assemble the instrument in less than 1.5 min and that a surgeon is able to reach all important locations on the menisci

    Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating

    Get PDF
    New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was to compare the stiffness and strength of locking compression plate (LCP) fixation to one-third tubular plate fixation in a cadaveric comminuted olecranon fracture model with a standardised osteotomy. Five matched pairs of cadaveric elbows were randomly assigned for fixation by either a contoured LCP combined with an intramedullary screw and unicortical locking screws or a one-third tubular plate combined with bicortical screws. Construct stiffness was measured by subjecting the specimens to cyclic loading while measuring gapping at the osteotomy site. Construct strength was measured by subjecting specimens to ramp load until failure. There was no significant difference in fixation stiffness and strength between the two fixation methods. All failures consisted of failure of the bone and not of the hardware. Contoured LCP and intramedullary screw fixation can be used as an alternative treatment method for comminuted olecranon fractures as its stiffness and strength were not significantly different from a conventional plating techniqu

    The influence of foot geometry on the calcaneal osteotomy angle based on two-dimensional static force analyses

    Get PDF
    Background: Malalignment of the hindfoot can be corrected with a calcaneal osteotomy (CO). A well-selected osteotomy angle in the sagittal plane will reduce the shear force in the osteotomy plane while walking. The purpose was to determine the presence of a relationship between the foot geometry and loading of the calcaneus, which influences the choice of the preferred CO angle. Methods A static free body force analysis was made of the posterior calcaneal fragment in the second half of the stance phase to determine the main loads: the plantar apeunorosis (PA) and Achilles tendon (AT). The third load is on the osteotomy surface which should be oriented such that the shear component of the force is zero. The force direction of the PA and AT was measured on 58 MRIs of the foot, and the force ratio between both structures was taken from the literature. In addition the PA-to-AT force ratio was estimated for different foot geometries to identify the relationship. Results: Based on the wish to minimize the shear force during walking, a mean CO angle was determined to be 33º (SD8) relative to the foot sole. In pes planus foot geometry, the angle should be higher than the mean. In pes cavus foot geometry, the angle should be smaller. Conclusion: Foot geometry, in particular the relative foot heights is a determinant for the individual angle in performing the sliding calcaneal osteotomy. It is recommended to take into account the foot geometry (arch) when deciding on the CO angle for hindfoot correction.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin

    The influence of water jet diameter and bone structural properties on the efficiency of pure water jet drilling in porcine bone

    No full text
    Using water jets in orthopedic surgery to drill holes in bones can be beneficial due to the absence of thermal damage and the always sharp cut. To minimize operating time and the volume of water that is used, the efficiency (volume of removed bone per added volume of water) of the water jet should be maximized. The goal was to study the effect of the open trabecular bone structure on the efficiency for different water jet diameters. 86 holes were drilled in porcine tali and femora submerged in water with nozzles of 0.3, 0.4, 0.5 and 0.6 mm at 70 MPa during 5 s and a standoff distance of 8 mm. MicroCT scans were made to measure the removed bone volume and the bone structural properties Trabecular Spacing (Tb. Sp.), Trabecular Thickness (Tb. Sp.) and Bone Volume Fraction (BV/TV). Pearson's correlation tests (p <0.05, 95% confidence interval) were performed for each water jet diameter using the bone structural property as an independent factor and the efficiency as a dependent factor. No significant differences were found between the nozzle diameters in the material removal rates per added volume of water. The efficiency decreased for an increase in Tb. Th. and BV/TV for nozzles of 0.3, 0.4 and 0.5 mm. The 0.6 mm nozzle showed less influence of the Tb. Th. and BV/TV. The Tb. Sp. has no influence on the efficiency of a water jet. The total volume of added water combined with the Tb. Th. or BV/TV is a leading measure for the volume of bone material that is removed, which provides freedom in the development of water jet instruments as the nozzle diameter, pressure and jet time can be chosen in accordance to the maximum operating time requirements or dimensional limitations of a desig
    corecore