1,054 research outputs found
Short-Run Economic Impacts of Hurricane Katrina (and Rita)
Sturm; Erdölförderung; Offshore-Industrie; Makroökonomischer Einfluss; USA
Ultrasonic Inspection of Graphite-Epoxy Solid Rocket Motor Canisters
Thick filament-wound composite materials are particularly attractive for use in solid rocket motor structures. However, these materials are difficult to inspect because of the scattering losses associated with multiple fiber layers. Damage caused by either low or high velocity impact which results in matrix cracking, delaminations and broken fibers cannot be tolerated because of the possibility of catastrophic system failure. American Research Corporation of Virginia has performed a 2-year Phase II Small Business Innovation Research contract to develop an ultrasonic inspection system for graphite/epoxy rocket motor canisters [1]. This paper details the experimental apparatus and testing of rocket motor canisters, presents testing results and discusses observations and detection thresholds
Analysis and use of VAS satellite data
A series of interrelated investigations has examined the analysis and use of VAS (VISSR Atmospheric Sounder) satellite data. A case study of VAS-derived mesoscale stability parameters suggested that they would have been a useful supplement to conventional data in the forecasting of thunderstorms on the day of interest. However, the meteorological significance of small or short lived stability features was uncertain. A second investigation examined the roles of first guess and VAS radiometric data in producing sounding retrievals. The radiance data often did not have a decisive influence on the final satellite soundings. Broad-scale patterns of the first guess, radiances, and retrievals frequently were similar, whereas small scale retrieval features, especially in the dew points, were often of uncertain origin
Analysis and use of VAS satellite data
Four interrelated investigations have examined the analysis and use of VAS satellite data. A case study of VAS-derived mesoscale stability parameters suggested that they would have been a useful supplement to conventional data in the forecasting of thunderstorms on the day of interest. A second investigation examined the roles of first guess and VAS radiometric data in producing sounding retrievals. Broad-scale patterns of the first guess, radiances, and retrievals frequently were similar, whereas small-scale retrieval features, especially in the dew points, were often of uncertain origin. Two research tasks considered 6.7 micron middle tropospheric water vapor imagery. The first utilized radiosonde data to examine causes for two areas of warm brightness temperature. Subsidence associated with a translating jet streak was important. The second task involving water vapor imagery investigated simulated imagery created from LAMPS output and a radiative transfer algorithm. Simulated image patterns were found to compare favorably with those actually observed by VAS. Furthermore, the mass/momentum fields from LAMPS were powerful tools for understanding causes for the image configurations
Type 2 cannabinoid receptor expression on microglial cells regulates neuroinflammation during graft-versus-host disease
Neuroinflammation is a recognized complication of immunotherapeutic approaches such as immune checkpoint inhibitor treatment, chimeric antigen receptor therapy, and graft versus host disease (GVHD) occurring after allogeneic hematopoietic stem cell transplantation. While T cells and inflammatory cytokines play a role in this process, the precise interplay between the adaptive and innate arms of the immune system that propagates inflammation in the central nervous system remains incompletely understood. Using a murine model of GVHD, we demonstrate that type 2 cannabinoid receptor (CB2R) signaling plays a critical role in the pathophysiology of neuroinflammation. In these studies, we identify that CB2R expression on microglial cells induces an activated inflammatory phenotype that potentiates the accumulation of donor-derived proinflammatory T cells, regulates chemokine gene regulatory networks, and promotes neuronal cell death. Pharmacological targeting of this receptor with a brain penetrant CB2R inverse agonist/antagonist selectively reduces neuroinflammation without deleteriously affecting systemic GVHD severity. Thus, these findings delineate a therapeutically targetable neuroinflammatory pathway and have implications for the attenuation of neurotoxicity after GVHD and potentially other T cell-based immunotherapeutic approaches
New result for the neutron -asymmetry parameter from UCNA
The neutron -decay asymmetry parameter defines the correlation
between the spin of the neutron and the momentum of the emitted electron, which
determines , the ratio of the axial-vector to
vector weak coupling constants. The UCNA Experiment, located at the Ultracold
Neutron facility at the Los Alamos Neutron Science Center, is the first to
measure such a correlation coefficient using ultracold neutrons (UCN).
Following improvements to the systematic uncertainties and increased
statistics, we report the new result which yields . Combination with the previous UCNA result and
accounting for correlated systematic uncertainties produces
and .Comment: 9 pages, 7 figures, updated to as-published versio
Search for neutron dark decay: n → χ + e⁺e⁻
In January, 2018, Fornal and Grinstein proposed that a previously unobserved neutron decay branch to a dark matter particle (χ) could account for the discrepancy in the neutron lifetime observed in two different types of experiments. One of the possible final states discussed includes a single χ along with an e⁺e⁻ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with ∼ 4π acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). We use the timing information of coincidence events to select candidate dark sector particle decays by applying a timing calibration and selecting events within a physically-forbidden timing region for conventional n → p + e⁻ + ν̅_e decays. The summed kinetic energy (E_(e⁺e⁻)) from such events is reconstructed and used to set limits, as a function of the χ mass, on the branching fraction for this decay channel
Tracing the Mass during Low-Mass Star Formation, IV: Observations and Modeling of the Submillimeter Continuum Emission from Class I Protostars
We present results from the observations and modeling of seventeen Class I
cores with the Submillimetre Common Users Bolometer Array (SCUBA) on the James
Clerk Maxwell Telescope (JCMT). By modeling the transfer of radiation through
the envelope for nine cores, we find, for a power law distribution
n(r)=n_f(r/r_f)^-p, the average and standard deviation p=1.6 +/- 0.4 and a
median of p=1.8. However, the inclusion of a disk or other point-like component
can cause the derived p to be shallower by as much as 0.5. In addition, we test
the Shu collapse model for our sources and discuss the application of simpler
analyses that derive a density power law distribution directly from the slope
of the intensity radial profile. The total mass of the envelope in our sample
has a range from 0.04 to 5.0 M_sun, but these masses disagree with the virial
masses derived from molecular line observations. Finally, we discuss the nature
of these sources in light of various evolutionary indicators and find that
T_bol and L_obs/L_smm are often inconsistent in distinguishing Class 0 from
Class I cores.Comment: Accepted to ApJS. 50 pages with 27 figures and 12 tables.
High-resolution figures at http://peggysue.as.utexas.edu/cyoung
Final results for the neutron β-asymmetry parameter A₀ from the UCNA experiment
The UCNA experiment was designed to measure the neutron β-asymmetry parameter A0 using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for A0 was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008–2009, 2010, and 2011–2013, which ultimately culminated in a 0.67% precision result for A₀
- …