EABR on cochlear implant - measurements from clinical routine compared to reference values
Measurements of electrically evoked potentials of the auditory system (EAEP) are important cornerstones of objective diagnostics in cochlear implant care. For differential diagnosis, the combined evaluation of electrically evoked compound action potentials (ECAP) and electrically evoked brainstem responses (EABR) can be used. The aim of this case series is to compare measurements from difficult cases to previously published reference values of ECAP and EABR.The reference values for ECAP and EABR were determined using a broadband stimulus on 20 CI patients with normal speech recognition scores. Five cases of EAEP measurements from clinical routine will be presented and discussed in comparison to the reference values.For both ECAP and EABR, reference values of amplitude growth functions, absolute latencies and latency differences were obtained. The following cases are shown in comparison to the reference values: Normal findings; EABR at initial CI fitting; Extended latencies; Objective evaluation before re-implantation; Unexpected insufficient speech perception. Based on the reference values, a comprehensive differential diagnosis of the peripheral auditory system is possible
Vergleichswerte elektrophysiologischer Messungen zur intraoperativen Lagekontrolle bei verschiedenen CI-Elektrodenträgern
Quality assured implantation and fitting of cochlear implants (CI) is based on several pre-, intra- and postoperative audiological measurement methods. Verification of CI electrode position is an important part of the intraoperative measurements during the implantation. Postoperative electrode localization checks are usually based on CT scan and conventional X-Ray and lead to an additional radiation exposure for the patient. Spread of Excitation measurement (SOE) is an alternative intraoperative electrophysiological method avoiding especially postoperative imaging techniques. Several studies have shown that this objective method can detect a "tip foldover" and is therefore suitable as a fast and cost efficient procedure to detect electrode displacements during the procedure. For evaluation this method needs standardized measurement protocols and electrode specific normal values. In our study this was performed, analyzed and discussed in 37 patients using different electrodes.Die Grundlage für eine qualitätsgesicherte Versorgung mit Cochlea-Implantaten (CI) bilden eine Reihe prä-, intra- und postoperativer audiologischer Messmethoden. Die postoperative Kontrolle der CI-Elektrodenlage ist dabei ein wichtiger Bestandteil der operativen Phase der CI-Versorgung. Diese erfolgt konventionell radiologisch, welche jedoch mit einer zusätzlichen Strahlenbelastung für den Patienten verbunden ist. Ein alternatives rein funktionsdiagnostisches Verfahren ohne Strahlenbelastung stellt die Spread Of Excitation-Messung (SOE) dar. In früheren Arbeiten konnten die Autoren zeigen, dass durch dieses Verfahren ein intraoperativ aufgetretenes "Tip-Foldover" nachgewiesen werden kann. Prinzipiell eignet sie sich somit als schnelle, belastungsfreie und auch kostengünstige Prozedur zur Objektivierung und Differenzierung einer Elektrodenfehllage. Für die Etablierung eines solchen Verfahrens sind ein einheitliches Vorgehen bei der SOE-Messung sowie elektrodenspezifische Vergleichswerte (Normdaten) notwendig. In dieser Arbeit werden von den Autoren ein geeignetes Test-Setting, SOE-Messungen von insgesamt 37 Patienten mit verschiedenen Elektrodenträgern sowie ein Normierungsverfahren vorgestellt und diskutier