8,857 research outputs found

    Homogenization of two fluid flow in porous media

    No full text
    The macroscopic behavior of air and water in porous media is often approximated using Richards’ equation for the fluid saturation and pressure. This equation is parametrized by the hydraulic conductivity and water release curve. In this paper, we use homogenization to derive a general model for saturation and pressure in porous media based on an underlying periodic porous structure. Under an appropriate set of assumptions, i.e., constant gas pressure, this model is shown to reduce to the simpler form of Richards’ equation. The starting point for this derivation is the Cahn-Hilliard phase field equation coupled with Stokes equations for fluid flow. This approach allows us, for the first time, to rigorously derive the water release curve and hydraulic conductivities through a series of cell problems. The method captures the hysteresis in the water release curve and ties the macroscopic properties of the porous media to the underlying geometrical and material properties

    Mechanism of droplet-formation in a supersonic microfluidic spray device

    Get PDF
    Spray drying is an approach employed in automotive, food, and pharmaceutical industries as a robust and cost efficient liquid atomization technique offering direct control over droplet dimensions. The majority of commercially available spray nozzles are designed for large throughput spray drying applications or uniform surface coating, but microfluidic nebulizers have recently been developed as small scale alternatives. Here, we explore the physical parameters that define the droplet size and formation under supersonic flow conditions commonly found in microfluidic spray drying systems. We examined the spray nozzle operation using high speed imaging and laser scattering measurements, which allowed us to describe the spray regimes and droplet size distributions. It was determined that by using this spray nozzle device, droplets with diameters of 4–8 μm could be generated. Moreover, we show that the supersonic de Laval nozzle model can be used to predict the average droplet size. Our approach can be used as a platform for interfacing fluid microprocessing with gas phase detection and characterization

    Challenges in imaging and predictive modeling of rhizosphere processes

    Get PDF
    Background Plant-soil interaction is central to human food production and ecosystem function. Thus, it is essential to not only understand, but also to develop predictive mathematical models which can be used to assess how climate and soil management practices will affect these interactions. Scope In this paper we review the current developments in structural and chemical imaging of rhizosphere processes within the context of multiscale mathematical image based modeling. We outline areas that need more research and areas which would benefit from more detailed understanding. Conclusions We conclude that the combination of structural and chemical imaging with modeling is an incredibly powerful tool which is fundamental for understanding how plant roots interact with soil. We emphasize the need for more researchers to be attracted to this area that is so fertile for future discoveries. Finally, model building must go hand in hand with experiments. In particular, there is a real need to integrate rhizosphere structural and chemical imaging with modeling for better understanding of the rhizosphere processes leading to models which explicitly account for pore scale processes

    Mid-femoral and mid-tibial muscle cross-sectional area as predictors of tibial bone strength in middle-aged and older men

    Full text link
    While it is widely acknowledged that bones adapt to the site-specific prevalent loading environment, reasonable ways to estimate skeletal loads are not necessarily available. For long bone shafts, muscles acting to bend the bone may provide a more appropriate surrogate of the loading than muscles expected to cause compressive loads. Thus, the aim of this study was to investigate whether mid-thigh muscle cross-sectional area (CSA) was a better predictor of tibial mid-shaft bone strength than mid-tibia muscle CSA in middle aged and older men. 181 Caucasian men aged 50–79 years (mean±SD; 61±7 years) participated in this study. Mid-femoral and mid-tibial bone traits cortical area , density weighted polar moment of area and muscle CSA [cm²] were assessed with computed tomography. Tibial bone traits were positively associated with both the mid-femur (r=0.44 to 0.46, P<0.001) and the mid-tibia muscle CSA (r=0.35 to 0.37, P<0.001). Multivariate regression analysis, adjusting for age, weight, physical activity and femoral length, indicated that mid-femur muscle CSA predicted tibial mid-shaft bone strength indices better thn mid-tibia muscle CSA. In conclusion, the association between a given skeletal site and functionally adjacent muscles may provide a meaningful probe of the site-specific effect of loading on bone

    An open source approach for regional cortical bone mineral density analysis

    Full text link
    Objective: Cortical porosity, particularly at the endocortical region, is recognised to play a central role in the pathogenesis of bone fragility. Therefore, the purpose of this study was to: 1) demonstrate how cortical volumetric BMD (vBMD) distribution can be analysed from (p)QCT images and 2) highlight the clinical significance of assessing regional density distribution of cortical bone.&nbsp; Methods: We used pQCT to compare mid-tibial cortical volumetric BMD distribution of 20 young (age 24(SD2) years, mass 77(11) kg, height 178(6) cm) and 25 elderly (72(4) years, 75(9) kg, 172(5) cm) men. Radial and polar cortical vBMD distributions were analysed using a custom built open source analysis tool which allowed the cortex to be divided into three concentric cortical divisions and in 36 cortical sectors originating from the centroid of the bone. Results: Mean vBMD did not differ between the groups (1135(16) vs. 1130(28) mg/cm, P=0.696). In contrast, there was a significant age-group by radial division interaction for radial cortical vBMD (P&lt;0.001). Conclusions: The proposed analysis method for analysing cortical bone density distribution of pQCT images was effective for detecting regional differences in cortical density between young and elderly men, which would have been missed by just looking at mean vBMD values.<br /

    Evaluation of a spring-powered captive bolt gun for killing kangaroo pouch young

    Get PDF
    Context: During commercial harvesting or non-commercial kangaroo culling programs, dependent young of shot females are required to be euthanased to prevent suffering and because they would be unlikely to survive. However, the current method for killing pouch young, namely a single, forceful blow to the base of the skull, is applied inconsistently by operators and perceived by the public to be inhumane. Aims: To determine whether an alternative method for killing pouch young, namely a spring-operated captive bolt gun, is effective at causing insensibility in kangaroo pouch young. Methods: Trials of spring-operated captive bolt guns were conducted first on the heads of 15 dead kangaroo young and then on 21 live pouch young during commercial harvesting. We assessed the effectiveness at causing insensibility in live animals and damage caused to specific brain areas. We also measured depth of bolt penetration and skull thickness. Performance characteristics (e.g. bolt velocity) of two types of spring-operated guns were also measured and compared with cartridge-powered devices. Key results: When tested on the heads of dead animals, the spring-operated captive bolt gun consistently produced a large entrance cavity and a well defined wound tract, which extended into the cerebrum, almost extending the full thickness of the brain, including the brainstem. When tested on live pouch young, the captive bolt gun caused immediate insensibility in only 13 of 21 animals. This 62% success rate is significantly below the 95% minimum acceptable threshold for captive bolt devices in domestic animal abattoirs. Failure to stun was related to bolt placement, but other factors such as bolt velocity, bolt diameter and skull properties such as thickness and hardness might have also contributed. Spring-operated captive bolt guns delivered 20 times less kinetic energy than did cartridge-powered devices. Conclusions: Spring-operated captive bolt guns cannot be recommended as an acceptable or humane method for stunning or killing kangaroo pouch young. Implications: Captive bolt guns have potential as a practical alternative to blunt head trauma for effective euthanasia and reducing animal (and observer) distress. However, operators must continue to use the existing prescribed killing methods until cartridge-powered captive bolt guns have been trialled as an alternative bolt propelling method. Additional keywords: animal welfare, blunt trauma, culling, euthanasia, humaneness, kangaroo harvesting

    The effect of root exudates on rhizosphere water dynamics

    Get PDF
    L.J.C. and N.K. are funded by BBSRC SARISA BB/L025620/1, L.J.C. is also funded by EPSRC EP/P020887/1. K.R.D. is funded by ERC 646809DIMR. P.D.H. and T.S.G. are funded by BBSRC BB/J00868/1. The James Hutton Institute receives funding from the Scottish Government. T.R. is funded by BBSRC SARISA BB/L025620/1, EPSRC EP/M020355/1, ERC 646809DIMR, BBSRC SARIC BB/P004180/1 and NERC NE/L00237/1. Data supporting this study are available on request from the University of Southampton repository at https://doi.org/10.5258/SOTON/D0609 [35].Peer reviewedPublisher PD

    The Highly Miniaturised Radiation Monitor

    Full text link
    We present the design and preliminary calibration results of a novel highly miniaturised particle radiation monitor (HMRM) for spacecraft use. The HMRM device comprises a telescopic configuration of active pixel sensors enclosed in a titanium shield, with an estimated total mass of 52 g and volume of 15 cm3^3. The monitor is intended to provide real-time dosimetry and identification of energetic charged particles in fluxes of up to 108^8 cm2^{-2} s1^{-1} (omnidirectional). Achieving this capability with such a small instrument could open new prospects for radiation detection in space.Comment: 17 pages, 15 figure

    Fv antibodies to aflatoxin B1 derived from a pre-immunized antibody phage display library system

    Get PDF
    The production and characterization of recombinant antibodies to aflatoxin B[SUB1] (AFB[SUB1]), a potent mycotoxin and carcinogen is described. The antibody fragments produced were then applied for use in a surface plasmon resonance-based biosensor (BIAcore), which measures biomolecular interactions in 'real-time'. Single chain Fv (scFv) antibodies were generated to aflatoxin B1 from an established phage display system, which incorporated a range of different plasmids for efficient scFv expression. The scFv's were used in the development of a competitive ELISA, and also for the development of surface plasmon resonance (SPR)-based inhibition immunoassays. They were found to be suitable for the detection of AFB[SUB1], in this format, with the assays being sensitive and reproducible
    corecore