    New European Technical Rules for the Assessment and Retrofitting of Existing Structures.

    Get PDF
    The consideration of sustainability aspects in the construction sector jointly with considerable economic interests have been the main impulse to include the work item of assessment and retrofitting of existing structures in the Mandate M/515 with a high priority. The new European technical rules will be developed using the existing organization of CEN/TC250. The present report has been worked out in the frame of CEN/TC250/WG2 activities. The report encompasses: Part I introduces the policy framework and the CEN/TC250 initiative. Part II is a collation of the different existing National regulations and standards in Europe with regard to existing structures. Part III gives a prospect for CEN guidance for the assessment and retrofitting of existing structures. Having in mind the stepwise procedure for preparation of CEN Technical Documents, the contents of Part III is broader, covers more aspects, and includes more information than the normative technical recommendations. In particular, key issues are identified that require resolution and a summary of different national perspectives is provided rather than seeking to resolve all difficult technical issues during the first work step. The report presents scientific and technical background intended to stimulate debate and serves as a basis for further work to achieve a harmonized European view on the assessment and retrofitting of existing structures.JRC.G.4-European laboratory for structural assessmen

    Rekenregels beoordeling bestaande breedplaatvloeren:Resultaten onderzoek constructieve veiligheid in bestaande utiliteitsgebouwen

    No full text
    Naar aanleiding van het gedeeltijke bezwijken van de parkeergarage bij Eindhoven Airport is onderzoek uitgevoerd naar de weerstand van breedplaatvloeren. Dit onderzoek is beschreven in rapport 9780-1-0 van Adviesbureau Hageman. Het onderzoek heeft geresulteerd in rekenregels die gebruikt kunnen worden voor de beoordeling van bestaande breedplaatvloeren waarbij sprake is van primaire krachtsafdracht over een doorsnede ter plaatse van de naad\u3cbr/\u3etussen twee breedplaten. Het artikel geeft een samenvatting van het rapport

    Approach to assessment of existing structures in the fib Model Code 2020

    No full text
    Existing structures often no longer meet the demands formulated in contemporary design codes with respect to structural safety and serviceability. This occurs, for instance, if the loads on existing structures, like traffic loads on bridges, are larger than assumed in the original design. A second potential reason is that structures are subject to deterioration, like alkali–silica reaction within the concrete or corrosion of the reinforcement due to chloride attack or carbonation. A third possible reason is that in recent codes, additional criteria have been introduced based on new theories and/or negative experiences with older structures. The new fib Model Code for Concrete Structures 2020 will be valid both for the design of new structures and the assessment of existing structures. This paper shows how the design and assessment of concrete structures are integrated into this new code concept.Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Concrete Structure

    Rekenregels beoordeling bestaande breedplaatvloeren: Resultaten onderzoek constructieve veiligheid in bestaande utiliteitsgebouwen

    Get PDF
    Naar aanleiding van het gedeeltijke bezwijken van de parkeergarage bij Eindhoven Airport is onderzoek uitgevoerd naar de weerstand van breedplaatvloeren. Dit onderzoek is beschreven in rapport 9780-1-0 van Adviesbureau Hageman. Het onderzoek heeft geresulteerd in rekenregels die gebruikt kunnen worden voor de beoordeling van bestaande breedplaatvloeren waarbij sprake is van primaire krachtsafdracht over een doorsnede ter plaatse van de naad tussen twee breedplaten. Het artikel geeft een samenvatting van het rapport