6 research outputs found

    Biofabrication Enables Efficient Interrogation and Optimization of Sequential Culture of Endothelial Cells, Fibroblasts, and Cardiomyocytes for Formation of Vascular Cords in Cardiac Tissue Engineering

    Get PDF
    Biofabrication of living structures with desired topology and functionality requires the interdisciplinary effort of practitioners of the physical, life and engineering sciences. Such efforts are being undertaken in many laboratories around the world. Numerous approaches are pursued, such as those based on the use of natural or artificial scaffolds, decellularized cadaveric extracellular matrices and, most lately, bioprinting. To be successful in this endeavor, it is crucial to provide in vitro micro-environmental clues for the cells resembling those in the organism. Therefore, scaffolds, populated with differentiated cells or stem cells, of increasing complexity and sophistication are being fabricated. However, no matter how sophisticated scaffolds are, they can cause problems stemming from their degradation, eliciting immunogenic reactions and other a priori unforeseen complications. It is also being realized that ultimately the best approach might be to rely on the self-assembly and self-organizing properties of cells and tissues and the innate regenerative capability of the organism itself, not just simply prepare tissue and organ structures in vitro followed by their implantation. Here we briefly review the different strategies for the fabrication of three-dimensional biological structures, in particular bioprinting. We detail a fully biological, scaffoldless, print-based engineering approach that uses self-assembling multicellular units as bio-ink particles and employs early developmental morphogenetic principles, such as cell sorting and tissue fusion

    Vascular Endothelial Growth Factor Secretion by Nonmyocytes Modulates Connexin-43 Levels in Cardiac Organoids

    Get PDF
    We previously showed that the sequential, but not simultaneous, culture of endothelial cells (ECs), fibroblasts (FBs), and cardiomyocytes (CMs) resulted in elongated, beating cardiac organoids. We hypothesized that the expression of Cx43 and contractile function are mediated by vascular endothelial growth factor (VEGF) released by nonmyocytes during the preculture period. Cardiac organoids (200 μm diameter) were cultivated in microchannels to enable rapid screening. Three experimental groups were formed: (i) Simultaneous Preculture (ECs+FBs for 48 h, followed by CMs), (ii) Sequential Preculture (ECs for 24 h, FBs for 24 h, followed by CMs), and (iii) Simultaneous Triculture (ECs+FBs+CMs). Controls included CMs only, FBs only, and ECs only groups, and preculture with ECs only or FBs only. The highest VEGF levels were found in the Preculture groups [Simultaneous Preculture, 8.9 plus or minus 2.7 ng/(mL times h−1); Sequential Preculture, 16.6 plus or minus 3.4 ng/(mL times h−1)], as compared with Simultaneous Triculture where VEGF was not detectable, as shown by enzyme-linked immunosorbent assay. Analytical flow cytometry showed that VEGFR2 was expressed by ECs (86% plus or minus 2 VEGFR2+), FBs (44% plus or minus 1 VEGFR2+), and CMs (49% plus or minus 2 VEGFR2+), showing that all three cell types were capable of responding to changes in VEGF. Addition of anti-VEGF neutralizing IgG (0.4 μg/mL) to Simultaneous Preculture resulted in 3-fold decrease in Cx43 mRNA and 1.5-fold decrease in Cx43 protein, while Simultaneous Triculture supplemented with VEGF ligand (30 ng/mL) had a threefold increase in Cx43 mRNA and a twofold increase in Cx43 protein. Addition of a small molecule inhibitor of the VEGFR2 receptor (19.4 nM) to Sequential Preculture caused a 1.4-fold decrease in Cx43 mRNA and a 4.1-fold decrease in Cx43 protein. Cx43 was localized within CMs, and not within FBs or ECs. Enriched CM organoids and Sequential Preculture organoids grown in the presence of VEGFR2 inhibitor displayed low levels of Cx43 and poor functional properties. Taken together, these results suggest that endogenous VEGF-VEGFR2 signaling enhanced Cx43 expression and cardiac function in engineered cardiac organoids

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead

    Characterization of Mechanical and Dielectric Properties of Silicone Rubber

    No full text
    Silicone rubber’s silicone-oxygen backbones give unique material properties which are applicable in various biomedical devices. Due to the diversity of potential silicone rubber compositions, the material properties can vary widely. This paper characterizes the dielectric and mechanical properties of two different silicone rubbers, each with a different cure system, and in combination with silicone additives. A tactile mutator (Slacker™) and/or silicone thickener (Thi-vex™) were mixed with platinum-cured and condensation-cured silicone rubber in various concentrations. The dielectric constants, conductivities, and compressive and shear moduli were measured for each sample. Our study contributes novel information about the dielectric and mechanical properties of these two types of silicone rubber and how they change with the addition of two common silicone additives
    corecore