1,701 research outputs found

    Anisotropy and directional pinning in YBaCuO with BaZrO3 nanorods

    Full text link
    Measurements of anisotropic transport properties (dc and high-frequency regime) of driven vortex matter in YBa2_2Cu3_3O7−x_{7-x} with elongated strong-pinning sites (c-axis aligned, self-assembled BaZrO3_3 nanorods) are used to demonstrate that the effective-mass angular scaling takes place only in intrinsic physical quantities (flux-flow resistivity), and not in pinning-related Labusch parameter and critical currents. Comparison of the dynamics at different time scales shows evidence for a transition of the vortex matter toward a Mott phase, driven by the presence of nanorods. The strong pinning in dc arises partially from a dynamic effect.Comment: 4 pages, 4 figures. Accepted for publication on Applied Physics Letters. With respect to v1: changed title, slightly shortene

    Hybrid Superconducting Neutron Detectors

    Full text link
    A new neutron detection concept is presented that is based on superconductive niobium (Nb) strips coated by a boron (B) layer. The working principle of the detector relies on the nuclear reaction 10B+n →\rightarrow α\alpha+ 7Li , with α\alpha and Li ions generating a hot spot on the current-biased Nb strip which in turn induces a superconducting-normal state transition. The latter is recognized as a voltage signal which is the evidence of the incident neutron. The above described detection principle has been experimentally assessed and verified by irradiating the samples with a pulsed neutron beam at the ISIS spallation neutron source (UK). It is found that the boron coated superconducting strips, kept at a temperature T = 8 K and current-biased below the critical current Ic, are driven into the normal state upon thermal neutron irradiation. As a result of the transition, voltage pulses in excess of 40 mV are measured while the bias current can be properly modulated to bring the strip back to the superconducting state, thus resetting the detector. Measurements on the counting rate of the device are presented and the future perspectives leading to neutron detectors with unprecedented spatial resolutions and efficiency are highlighted.Comment: 8 pages 6 figure

    Exclusive tensor meson photoproduction

    Get PDF
    We study tensor meson photoproduction outside of the resonance region, at beam energies of few GeVs. We build a model based on Regge theory that includes the leading vector and axial exchanges. We consider two determinations of the unknown helicity couplings, and fit to the recent a2 photoproduction data from CLAS. Both choices give a similar description of the a2 cross section, but result in different predictions for the parity asymmetries and the f2 photoproduction cross section. We conclude that new measurements of f2 photoproduction in the forward region are needed to pin down the correct production mechanism. We also extend our predictions to the 8.5 GeV beam energy, where current experiments are running.Comment: 13 pages, 7 figures, 3 tables. Version accepted for publication on Phys.Rev.

    Colorectal cancer surgery in the very elderly patient: a systematic review of laparoscopic versus open colorectal resection.

    Get PDF
    INTRODUCTION: Colorectal cancer is the second most common cause of death from neoplastic disease in men and third in women of all ages. Globally, life expectancy is increasing, and consequently, an increasing number of operations are being performed on more elderly patients with the trend set to continue. Elderly patients are more likely to have cardiovascular and pulmonary comorbidities that are associated with increased peri-operative risk. They further tend to present with more locally advanced disease, more likely to obstruct or have disseminated disease. The aim of this review was to investigate the feasibility of laparoscopic colorectal resection in very elderly patients, and whether there are benefits over open surgery for colorectal cancer. METHODS: A systematic literature search was performed on Medline, Pubmed, Embase and Google Scholar. All comparative studies evaluating patients undergoing laparoscopic versus open surgery for colorectal cancer in the patients population over 85 were included. The primary outcomes were 30-day mortality and 30-day overall morbidity. Secondary outcomes were operating time, time to oral diet, number of retrieved lymph nodes, blood loss and 5-year survival. RESULTS: The search provided 1507 citations. Sixty-nine articles were retrieved for full text analysis, and only six retrospective studies met the inclusion criteria. Overall mortality for elective laparoscopic resection was 2.92% and morbidity 23%. No single study showed a significant difference between laparoscopic and open surgery for morbidity or mortality, but pooled data analysis demonstrated reduced morbidity in the laparoscopic group (p = 0.032). Patients undergoing laparoscopic surgery are more likely to have a shorter hospital stay and a shorter time to oral diet. CONCLUSION: Elective laparoscopic resection for colorectal cancer in the over 85 age group is feasible and safe and offers similar advantages over open surgery to those demonstrated in patients of younger ages

    Sexual dysfunction following rectal cancer surgery

    Get PDF
    INTRODUCTION: Sexual and urological problems after surgery for rectal cancer are common, multifactorial, inadequately discussed, and untreated. The urogenital function is dependent on dual autonomic sympathetic and parasympathetic innervation, and four key danger zones exist that are at risk for nerve damage during colorectal surgery: one of these sites is in the abdomen and three are in the pelvis. The aim of this study is to systematically review the epidemiology of sexual dysfunction following rectal cancer surgery, to describe the anatomical basis of autonomic nerve-preserving techniques, and to explore the scientific evidence available to support the laparoscopic or robotic approach over open surgery. METHODS: According to the PRISMA guidelines, a comprehensive literature search of studies evaluating sexual function in patients undergoing rectal surgery for cancer was performed in Medline, Scopus, Web of Science, Embase, and Cochrane Central Register of controlled trials. RESULTS: An increasing number of studies assessing the incidence and prevalence of sexual dysfunction following multimodality treatment for rectal cancer has been published over the last 30 years. Significant heterogeneity in the prevalence of sexual dysfunction is reported in the literature, with rates between 5 and 90%. CONCLUSIONS: There is no evidence to date in favor of any surgical approach (open vs laparoscopic vs robotic). Standardized diagnostic tools should be routinely used to prospectively assess sexual function in patients undergoing rectal surgery

    Effect of nanosize BaZrO3 inclusions on vortex parameters in YBaCuO

    Full text link
    We report on the field dependence of the microwave complex resistivity data in YBa2_2Cu3_3O7−x_{7-x}/BaZrO3_3 films grown by PLD at various BaZrO3_3 content. The data, analyzed within a recently developed general framework for the mixed-state microwave response of superconductors, yield the field dependence of the fluxon parameters such as the vortex viscosity and the pinning constant. We find that pinning undergoes a change of regime when the BaZrO3_3 content in the target increases from 2.5 mol.% to 5 mol.%. Simultaneously, the vortex viscosity becomes an increasing function of the applied magnetic field. We propose a scenario in which flux lines are pinned as bundles, and a crossover from dilute point pins to dense c-axis correlated defects takes place between 2.5 and 5 mol.% in the BZO concentration. Our data are inconsistent with vortices occupying mainly the BaZrO3_3 sites at low fields, and suggest instead that vortices occupy both BaZrO3_3 sites and interstitials in the YBa2_2Cu3_3O7−x_{7-x} matrix, even at low fields.Comment: Presented at EUCAS 2009, to be published in J. Phys.:Conf. Serie

    Macular pigment optical density and photophobia light threshold

    Get PDF
    AbstractLight absorption by macular pigment may attenuate visual discomfort, or photophobia, for targets composed of short-wavelength light. Macular pigment optical density (MPOD) and photophobia light thresholds were measured psychophysically in 10 subjects. The energy necessary to induce photophobia for a short-wavelength target relative to a long-wavelength target was linearly related to MPOD, as well as estimates of peak MPOD and integrated macular pigment. In four subjects who consumed lutein supplements, increases in MPOD corresponded to increases in photophobia light thresholds. Light absorption by macular pigment appears to influence the amount of short-wavelength light necessary to elicit photophobia

    Clinical experience with power-injectable PICCs in intensive care patients

    Get PDF
    Introduction: In the ICU, peripherally inserted central catheters (PICCs) may be an alternative option to standard central venous catheters, particularly in patients with coagulation disorders or at high risk for infection. Some limits of PICCs (such as low flow rates) may be overcome with the use of power-injectable catheters.Methods: We retrospectively reviewed all of the power-injectable PICCs inserted in adult and pediatric patients in the ICU during a 12-month period, focusing on the rate of complications at insertion and during maintenance.Results: We collected 89 power-injectable PICCs (in adults and in children), both multiple and single lumen. All insertions were successful. There were no major complications at insertion and no episodes of catheter-related bloodstream infection. Non-infective complications during management were not clinically significant. There was one episode of symptomatic thrombosis during the stay in the ICU and one episode after transfer of a patient to a non-intensive ward.Conclusion: Power-injectable PICCs have many advantages in the ICU: they can be used as multipurpose central lines for any type of infusion including high-flow infusion, for hemodynamic monitoring, and for high-pressure injection of contrast media during radiological procedures. Their insertion is successful in 100% of cases and is not associated with significant risks, even in patients with coagulation disorders. Their maintenance is associated with an extremely low rate of infective and non-infective complications. © 2012 Pittiruti et al.; licensee BioMed Central Ltd
    • …
    corecore