53 research outputs found
Development of an X-band Photoinjector at SLAC
As part of a National Cancer Institute contract to develop a compact source
of monoenergetic X-rays via Compton backscattering, we have completed the
design and construction of a 5.5 cell Photoinjector operating at 11.424 GHz.
Successful completion of this project will result in the capability of
generating a monoenergetic X-ray beam, continuously tunable from 20 - 85 KeV.
The immediate goal is the development of a Photoinjector producing 7 MeV, 0.5
nC, sub-picosecond electron bunches with normalized RMS emittances of
approximately 1 pi-mm-mR at repetition rates up to 60 Hz. This beam will then
be further accelerated to 60 MeV using a 1.05 m accelerating structure. This
Photoinjector is somewhat different than the traditional 1.5 cell design both
because of the number of cells and the symmetrically fed input coupler cell.
Its operating frequency is also unique. Since the cathode is non-removable,
cold-test tuning was somewhat more difficult than in other designs. We will
present results of "bead-drop" measurements used in tuning this structure.
Initial beam measurements are currently in progress and results will be
presented as well as results of RF conditioning to high gradients at X-band.
Details of the RF system, emittance-compensating solenoid, and cathode laser
system as well as PARMELA simulations will also be presented.Comment: 3 pages, 6 figures, 1 Table, LINAC 200
Recommended from our members
Performance of a 150-MW S-band klystron
As part of an international collaboration, the Stanford Linear Accelerator Center (SLAC) klystron group has designed, fabricated, and tested a 60-Hz, 3-{mu}s, 150-MW S-band klystron built for Deutsches Elektronen Synchrotron (DESY). A test diode with a 535-kV, 700-A electron beam was constructed to verify the gun operation. The first klystron was built and successfully met design specifications. The 375-MW electron beam represents a new record for SLAC accelerator klystrons in terms of voltage, current, energy, and ruggedness of design. The rf output power is a 150% increase over the S-band tubes currently used in the two-mile-long linear accelerator at SLAC. This paper discusses design issues and experimental results of the diode and klystron
Recommended from our members
1.2 MW klystron for Asymmetric Storage Ring B Factory
A cw klystron operating at 476 MHz has been developed jointly by SLAC and Varian Associates. The unique set of characteristics of this tube were strongly guided by requirements of the fast feedback necessary to prevent oscillations of the storage ring beams caused by the detuned accelerating cavity. This requires a combination of bandwidth and short group delay within the klystron. The RF feedback stabilization scheme also requires amplitude modulation making it necessary to operate the klystron about 10% below saturation. Performance specifications and initial operating results are presented
Recommended from our members
Latest Results in SLAC 75-MW PPM Klystrons
75 MW X-band klystrons utilizing Periodic Permanent Magnet (PPM) focusing have been undergoing design, fabrication and testing at the Stanford Linear Accelerator Center (SLAC) for almost nine years. The klystron development has been geared toward realizing the necessary components for the construction of the Next Linear Collider (NLC). The PPM devices built to date which fit this class of operation consist of a variety of 50 MW and 75 MW devices constructed by SLAC, KEK (Tsukuba, Japan) and industry. All these tubes follow from the successful SLAC design of a 50 MW PPM klystron in 1996. In 2004 the latest two klystrons were constructed and tested with preliminary results reported at EPAC2004. The first of these two devices was tested to the full NLC specifications of 75 MW, 1.6 microseconds pulse length, and 120 Hz. This 14.4 kW average power operation came with a tube efficiency >50%. The most recent testing of these last two devices will be presented here. Design and manufacturing issues of the latest klystron, due to be tested by the Fall of 2005, are also discussed
Recommended from our members
Current Status of the Next Linear Collider X-Band Klystron Development Program
Klystrons capable of driving accelerator sections in the Next Linear Collider (NLC) have been developed at SLAC during the last decade. In addition to fourteen 50 MW solenoid-focused devices and a 50 MW Periodic Permanent Magnet focused (PPM) klystron, a 500 kV 75 MW PPM klystron was tested in 1999 to 80 MW with 3 {micro}s pulses, but very low duty. Subsequent 75 MW prototypes aimed for low-cost manufacture by employing reusable focusing structures external to the vacuum, similar to a solenoid electromagnet. During the PPM klystron development, several partners (CPI, EEV and Toshiba) have participated by constructing partial or complete PPM klystrons. After early failures during testing of the first two devices, SLAC has recently tested this design (XP3-3) to the full NLC specifications of 75 MW, 1.6 {micro}s pulse length, and 120 Hz. This 14.4 kW average power operation came with an efficiency of 50%. The XP3-3 average and peak output power, together with the focusing method, arguably makes it the most advanced high power klystron ever built anywhere in the world. Design considerations and test results for these latest prototypes will be presented
Recommended from our members
High gradient electron guns
Experiments have been conducted to determine peak operating gradients attainable in thermionic electron guns. These tests are part of a study of high-current-density, long-life cathodes suitable for use in high power klystrons. We also investigated the use of chromium oxide coating as a means of inhibiting electronic breakdown across the focus electrode anode gap. Field gradients in excess of 280 kV/cm have been achieved for a gun operating at 240 kV with a beam current of 228 A, at pulse widths of the order of 1 {mu}s. 3 refs., 5 figs
Recommended from our members
MM-Wave Cavity/Klystron Developments Using Deep X-Ray Lithography at the Advanced Photon Source
Recent microfabrication technologies based on LIGA (German acronym for Lithographe, Galvanoformung, und Abformung) have been applied to build high-aspect-ratio, metallic or dielectric, planar structures suitable for high-frequency rf cavity structures. The cavity structures would be used as parts of linear accelerators, microwave undulators, and mm-wave amplifiers. The microfabrication process includes manufacturing of precision x-ray masks, exposure of positive resist by x-rays through the mask, resist development, and electroforming of the final microstructure. Prototypes of a 32-cell, 108-GHz constant impedance cavity and a 66-cell, 94-GHz constant-gradient cavity were fabricated using the synchrotron radiation sources at APS. Preliminary design parameters for a 91-GHz modulator klystron along with an overview of the new technology are discussed
Recommended from our members
MM-wave cavity/klystron developments using deep x-ray lithography at the Advanced Photon Source.
Recent microfabrication technologies based on LIGA (German acronym for Li thographe, G alvanoformung, und A bformung) have been applied to build high-aspect-ratio, metallic or dielectric, planar structures suitable for high frequency rf cavity structures. The cavity structures would be used as parts of linear accelerators, microwave undulators, and mm-wave amplifiers. The microfabrication process includes manufacturing of precision x-ray masks, exposure of positive resist by x-rays through the mask, resist development, and electroforming of the final microstructure. Prototypes of a 32-cell, 108-GHz constant impedance cavity and a 66-cell, 94-GHz constant-gradient cavity were fabricated using the synchrotron radiation sources at APS. Preliminary design parameters for a 91- GHz modulator klystron along with an overview of the new technology are discussed
Recommended from our members
Recent Measurements And Plans for the SLAC Compton X-Ray Source
A compact source of monoenergetic X-rays, generated via Compton backscattering, has been developed in a collaboration between U.C Davis and SLAC. The source consists of a 5.5 cell X-band photoinjector, a 1.05 m long high gradient accelerator structure and an interaction chamber where a high power (TW), short pulse (sub-ps) infrared laser beam is brought into a nearly head-on collision with a high quality focused electron beam. Successful completion of this project will result in the capability of generating a monoenergetic X-ray beam, continuously tunable from 20 - 85 keV. We have completed a series of measurements leading up to the generation of monoenergetic X-rays. Measurements of essential electron beam parameters and the techniques used in establishing electron/photon collisions will be presented. We discuss the design of an improved interaction chamber, future electro-optic experiments using this chamber and plans for expanding the overall program to the generation of Terahertz radiation
- …