349 research outputs found

    Energy calibration at LEP using Nuclear Magnetic Resonance probes

    Get PDF
    The accurate Standard Model investigations carried out at LEP require knowledge of the beam energies of the order of a few 10-5. The resonant depolarisation method, used for absolute calibration in de dicated experiments, cannot be used to monitor continuously the beam energy during the physics runs. Moreover appreciable polarisation of the beams has not been measured above energies of 55 GeV. A me thod for continuous energy monitoring based on Nuclear Magnetic Resonance (NMR) probes mounted in tunnel magnets has been in use at LEP since 1995. The average field of the dipole magnets is sampled v ia 24 NMR probes mounted in the gap of the C-shaped yokes on top of the vacuum chamber. The probes are distributed over the 27 km of the accelerator. The probes are used for the continuous monitoring of the field during LEP operation and to determine the absolute field value

    Model of Dipole Field Variations in the LEP Bending Magnets

    Get PDF
    The determination of the Z mass at LEP requires a knowledge of the relative beam energy in the order of 10 ppm, therefore it is essential to understand the dipole field variations to the same level of accuracy. In LEP the bending magnet field shows a relative increase of the order of 100 ppm over 10 hours, which was found to be caused by leakage currents from railways flowing along the vacuum cham ber and temperature variations. A LEP dipole test bench was set up for systematic investigations. Field variations were monitored with NMR probes while the cooling water temperature of both coil and vacuum chamber was kept under control. The results lead to a parametrisation of the magnetic field variation as a function of the vacuum chamber current and temperature

    Luminosity measurements at LEP

    Get PDF
    Fast luminosity measurements are vital for the optimisation of the machine conditions needed for physics. At LEP this has been achieved since the startup by means of 16 small tungsen-silicon calorimeters measuring the rate of Bhabba scattering events. To increase the counting rate the detectors are placed close to the beams and mounted on collimator jaws. The rate of Bhabba scattering is calculated using the rate of coincidental detections of e- and e+ at both sides of the interaction point. The correction term arising from accidental off-momentum particle coincidence is calculated from the background rates. This technique could be successfully used at beam energies around 45 GeV since the correction term was small.Starting in '95 however, the energy of LEP has been increased up to 91.5 GeV per beam. In these conditions the background event rate almost doubles while the Bhabba cross section adopted and presented in this paper consists of checking the collinearity in the vertical plane of the particle tracks. This is obtained by measuring the vertical centre position of the showers inside the calorimeters using silicon strip detectors

    Rendimento de milho e braquiaria com diferentes doses de nitrogênio em cobertura em sistema agrossilvipastoril no Acre.

    Get PDF
    O objetivo deste trabalho foi avaliar o rendimento produtivo das culturas do milho e Brachiaria brizantha cv. Xaraés consorciadas, cultivadas a diferentes distâncias de árvores nativas de mulateiro (Calycophyllum spruceanum Benth) e com aplicação de diferentes doses de nitrogênio em cobertura, em um sistema agrossilvipastoril no Acre. O delineamento experimental utilizado foi de blocos ao acaso, arranjado em parcelas subdivididas, com duas posições de amostragem (Perto da Linha e Distante da Linha do mulateiro) nas parcelas e cinco doses de adubação nitrogenada em cobertura (0; 50; 100; 150; 200 kg ha) nas subparcelas, totalizando dez tratamentos. Foram avaliados na cultura do milho a altura de plantas, teor de clorofila foliar e a produtividade de grãos e para forragem o acúmulo de matéria seca. Constatou-se que a produtividade do milho não é afetada pelo mulateiro aos quatro anos de idade e a adubação nitrogenada em cobertura até a dose de 200 Kg ha de N aumenta linearmente a produtividade de grãos. A pastagem formada apresentou acúmulo de matéria seca da forragem estatisticamente igual para todos os tratamentos, aos 90 dias após a colheita do milho

    Status of the HIE-ISOLDE project at CERN

    Full text link
    The HIE-ISOLDE project represents a major upgrade of the ISOLDE nuclear facility with a mandate to significantly improve the quality and increase the intensity and energy of radioactive nuclear beams produced at CERN. The project will expand the experimental nuclear physics programme at ISOLDE by focusing on an upgrade of the existing Radioactive ion beam EXperiment (REX) linac with a 40 MV superconducting linac comprising thirty-two niobium-on-copper sputter-coated quarter-wave resonators housed in six cryomodules. The new linac will raise the energy of post-accelerated beams from 3 MeV/u to over 10 MeV/u. The upgrade will be staged to first deliver beam energies of 5.5 MeV/u using two high-β\beta cryomodules placed downstream of REX, before the energy variable section of the existing linac is replaced with two low-β\beta cryomodules and two additional high-β\beta cryomodules are installed to attain over 10 MeV/u with full energy variability above 0.45 MeV/u. An overview of the project including a status summary of the different R&D activities and the schedule will outlined.Comment: 7 pages, 12 figures, submitted to the Heavy Ion Accelerator Technology conference (HIAT) 2012, in Chicag

    The Influence of Train Leakage Currents on the LEP Dipole Field

    Get PDF
    The determination of the mass and the width of the Z boson at CERN's LEP accelerator, an e+e- storage ring with a circumference of approximately 27 kilometres, imposes heavy demands on the knowledge of the LEP counter-rotating electron and positron beam energies. The precision required is of the order of 1 MeV or »20 ppm frequency. Due to its size the LEP collider is influenced by various macroscopic and regional factors such as the position of the moon or seasonal changes of the rainfall in the area, as reported earlier. A new and not less surprising effect of the LEP energy was observed in 1995: railroad trains in the Geneva region perturb the dipole field. A parasitic flow of electricity, originating from the trains, travels along the LEP ground cable and the vacuum chamber, interacting with the dipole field. An account of the phenomenon with its explanation substantiated by dedicated measurements is presented

    Laser Wire Scanner Development on CTF II

    Get PDF
    A laser wire scanner is under development at CERN in the framework of the Compact Linear Collider study (CLIC). A first test has been carried out at the CLIC Test Facility II (CTF II) with the aim of developing a beam profile monitor for a low energy, high charge electron beam. In our set-up a 2.5 mJ, 1047 nm, 4 ps laser pulse interacts with a 50 MeV, 1 nC, 4 ps electron bunch. A scintillator detects up to 600 X-ray photons, with an average energy of 17 keV. In the present status of the experiment Thomson photons have been observed, but the signal to noise ratio is however still too low for an accurate profile measurement
    corecore