79 research outputs found

    Analysis of polyethylene wear in plain radiographs: The number of radiographs influences the results

    Get PDF
    Background and purpose Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs

    The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures

    Get PDF
    Background and purpose: The application of radiostereometric analysis (RSA) to monitor stability of tibial plateau fractures during healing is both limited and yet to be validated. We therefore evaluated the accuracy and precision of RSA in a tibial plateau fracture model. Methods: Combinations of 3, 6, and 9 markers in a lateral condyle fracture were evaluated with reference to 6 proximal tibial arrangements. Translation and rotation accuracy was assessed with displacement-controlled stages, while precision was assessed with dynamic double examinations. A comparison of error according to marker number and arrangement was completed with 2-way ANOVA models. Results: The results were improved using more tantalum markers in each segment. In the fracture fragment, marker scatter in all axes was achieved by a circumferential arrangement (medial, anterior, and lateral) of the tantalum markers above the fixation devices. Markers placed on either side of the tibial tuberosity and in the medial aspect of the fracture split represented the proximal tibial reference segment best. Using 6 markers with this distribution in each segment, the translation accuracy (root mean square error) was less than 37 μm in all axes. The precision (95% confidence interval) was less than ± 16 μm in all axes in vitro. Rotation, tested around the x-axis, had an accuracy of less than 0.123° and a precision of ± 0.024°. Interpretation: RSA is highly accurate and precise in the assessment of lateral tibial plateau fracture fragment movement. The validation of our center's RSA system provides evidence to support future clinical RSA fracture studies.Lucian B Solomon, Aaron W Stevenson, Stuart A Callary, Thomas R Sullivan, Donald W Howie, and Mellick J Chehad

    Polyethylene Oxidation in Total Hip Arthroplasty: Evolution and New Advances

    Get PDF
    Ultra-high molecular weight polyethylene (UHMWPE) remains the gold standard acetabular bearing material for hip arthroplasty. Its successful performance has shown consistent results and survivorship in total hip replacement (THR) above 85% after 15 years, with different patients, surgeons, or designs

    The Elite-Plus stem migrates more than the flanged Charnley stem: A clinical, radiographic, and radiostereometric analysis of 114 patients with an average of 7 years follow-up

    Get PDF
    Background and purpose The Charnley Elite-Plus stem was introduced in 1993 as a presumed improvement of the flanged Charnley stem. We started this study in 1996 to investigate the migratory pattern of the Elite-Plus stem. Patients and methods We followed 114 patients with osteoarthritis and a primary total hip replacement with the Elite-Plus stem. Mean age at the time of operation was 64 (50-76) years. The mean follow-up time was 6.5 (2-7) years. Radiographs were evaluated with respect to cementing technique, migration, and wear measured by radiostereometry (RSA). Results The stem survival was 98% (CI: 96-100) at 7 years and 92% (CI: 86-97) at 10 years. Mean migration of the femoral head was 0.35 mm (SD 0.3) medially, 0.51 mm (SD 0.6) distally, and 1.1 mm (SD 1.8) in the dorsal direction. Mean total point motion was 1.7 mm (SD 1.7). The migration of the stems stabilized after 5 years in the medial and dorsal directions, but continued to subside slightly. Migration along any of the axes was higher if the cementing technique was inferior. Interpretation Patients with a Charnley Elite-Plus stem and defects in the cement mantle or other signs of inferior implantation technique should be carefully monitored

    Mechanical properties during healing of Achilles tendon ruptures to predict final outcome: A pilot Roentgen stereophotogrammetric analysis in 10 patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There are presently few methods described for in vivo monitoring of the mechanics of healing human tendon ruptures, and no methods for prediction of clinical outcome. We tested if Roentgen stereophotogrammetric analysis (RSA) can be used to follow the restoration of mechanical properties during healing of ruptured Achilles tendons, and if early measurements can predict clinical results.</p> <p>Methods</p> <p>Achilles tendon repair was studied with RSA in 10 patients with a total rupture. Tantalum beads were implanted in conjunction with surgical repair. The patients were evaluated at 6, 12 and 18 weeks, and after 1 year. RSA was performed with two different mechanical loadings, and the strain induced by increasing load was measured. The transverse area was determined by ultrasound. CT scan at 12 weeks confirmed that the tantalum beads were located within the tendons. Functional testing was done after 1 year. A heel raise index was chosen as primary clinical outcome variable.</p> <p>Results</p> <p>The strain was median 0.90, 0.32 and 0.14 percent per 100 N tendon force at 6 weeks, 18 weeks and one year respectively. The error of measurement was 0.04 percent units at 18 weeks. There was a large variation between patients, which appears to reflect biological variation. From 6 to 18 weeks, there was a negative correlation between increase in transverse area and increase in material properties, suggesting that healing is regulated at the organ level, to maximize stiffness. Modulus of elasticity during this time correlated with a heel raise index at one year (Rho = 0.76; p = 0.02).</p> <p>Conclusion</p> <p>We conclude that the RSA method might have potential for comparing different treatments of Achilles tendon ruptures.</p

    Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis

    Get PDF
    BACKGROUND: Proximal femoral bone loss during revision hip arthroplasty often requires bypassing the deficient metaphyseal bone to obtain distal fixation. The purpose of this study was to determine the effect of stem diameter and length of diaphyseal contact in achieving rotational stability in revision total hip arthroplasty. METHODS: Twenty-four cadaveric femoral specimens were implanted with a fully porous-coated stem. Two different diameters were tested and the stems were implanted at multiple contact lengths without proximal bone support. Each specimen underwent torsional testing to failure and rotational micromotion was measured at the implant-bone interface. RESULTS: The larger stem diameter demonstrated a greater torsional stability for a given length of cortical contact (p ≤ 0.05). Decreasing length of diaphyseal contact length was associated with less torsional stability. Torsional resistance was inconsistent at 2 cm of depth. CONCLUSION: Larger stem diameters frequently used in revisions may be associated with less diaphyseal contact length to achieve equivalent rotational stability compared to smaller diameter stems. Furthermore, a minimum of 3 cm or 4 cm of diaphyseal contact with a porous-coated stem should be achieved in proximal femoral bone deficiency and will likely be dependent on the stem diameter utilized at the time of surgery

    Assessment of bone ingrowth potential of biomimetic hydroxyapatite and brushite coated porous E-beam structures

    Get PDF
    The bone ingrowth potential of biomimetic hydroxyapatite and brushite coatings applied on porous E-beam structure was examined in goats and compared to a similar uncoated porous structure and a conventional titanium plasma spray coating. Specimens were implanted in the iliac crest of goats for a period of 3 (4 goats) or 15 weeks (8 goats). Mechanical implant fixation generated by bone ingrowth was analyzed by a push out test. Histomorphometry was performed to assess the bone ingrowth depth and bone implant contact. The uncoated and hydroxyapatite-coated cubic structure had significantly higher mechanical strength at the interface compared to the Ti plasma spray coating at 15 weeks of implantation. Bone ingrowth depth was significantly larger for the hydroxyapatite- and brushite-coated structures compared to the uncoated structure. In conclusion, the porous E-beam surface structure showed higher bone ingrowth potential compared to a conventional implant surface after 15 weeks of implantation. Addition of a calcium phosphate coating to the E-beam structure enhanced bone ingrowth significantly. Furthermore, the calcium phosphate coating appears to work as an accelerator for bone ingrowth