4 research outputs found

    a rare case of pacemaker lead endocarditis successfully treated with open heart surgery

    Get PDF
    Background: Cardiac device-related endocarditis has emerged as a serious complication in the era of advanced medical technology. Pacemaker related infections are rare and life-threatening with incidence from 0.06% to 7% and high mortality rate (30-35%). Diagnosis is hard, frequently delayed and could be even missed due to poor clinical findings. The average delay in diagnosis is 5.5 month. We report a case of the late-onset of pacemaker lead endocarditis caused by S. epidermidis successfully treated with open heart surgery. Case Report: Patient with persistent high fever for 11 month and suspicion for infective endocarditis was admitted in Cardiovascular Institute. No clinical signs of endocarditis were observed. TTE revealed large vegetation 30 × 17 mm attached to the atrial electrodes with high embolic potential. This finding was verified by transesophageal echocardiography (TEE), although CT scan did not reveal vegetation. Blood cultures were negative. A sternotomy with cardiopulmonary bypass was performed and electrodes were extracted with large vegetation. Intraoperative finding revealed large thrombus with vegetation around pacemaker leads. Cultures of the electrodes and vegetation revealed Staphylococcus epidermidis. Surgery was followed up with antibiotic treatment for 6 weeks. He has been followed up for the next 2 years, and without complications. Conclusion: The absence of criteria for endocarditis and negative blood cultures should not keep the physician from ruling out lead endocarditis. This complication carries high risk of mortality if left untreated

    Impact of COVID-19 Pandemic on TAVR Activity: A Worldwide Registry

    Get PDF
    Background: The COVID-19 pandemic had a considerable impact on the provision of structural heart intervention worldwide. Our objectives were: 1) to assess the impact of the COVID-19 pandemic on transcatheter aortic valve replacement (TAVR) activity globally; and 2) to determine the differences in the impact according to geographic region and the demographic, development, and economic status of diverse international health care systems. Methods: We developed a multinational registry of global TAVR activity and invited individual TAVR sites to submit TAVR implant data before and during the COVID-19 pandemic. Specifically, the number of TAVR procedures performed monthly from January 2019 to December 2021 was collected. The adaptive measures to maintain TAVR activity by each site were recorded, as was a variety of indices relating to type of health care system and national economic indices. The primary subject of interest was the impact on TAVR activity during each of the pandemic waves (2020 and 2021) compared with the same period pre–COVID-19 (2019). Results: Data were received from 130 centers from 61 countries, with 14 subcontinents and 5 continents participating in the study. Overall, TAVR activity increased by 16.7% (2,337 procedures) between 2018 and 2019 (ie, before the pandemic), but between 2019 and 2020 (ie, first year of the pandemic), there was no significant growth (–0.1%; –10 procedures). In contrast, activity again increased by 18.9% (3,085 procedures) between 2020 and 2021 (ie, second year of the pandemic). During the first pandemic wave, there was a reduction of 18.9% (945 procedures) in TAVR activity among participating sites, while during the second and third waves, there was an increase of 6.7% (489 procedures) and 15.9% (1,042 procedures), respectively. Further analysis and results of this study are ongoing and will be available at the time of the congress. Conclusion: The COVID-19 pandemic initially led to a reduction in the number of patients undergoing TAVR worldwide, although health care systems subsequently adapted, and the number of TAVR recipients continued to grow in subsequent COVID-19 pandemic waves. Categories: STRUCTURAL: Valvular Disease: Aorti

    Early Outcomes of a Next-Generation Balloon-Expandable Transcatheter Heart Valve - The Myval System: A Single-Center Experience From Serbia

    No full text
    Transcatheter aortic valve implantation (TAVI) is one of the most effective treatments for severe aortic valve stenosis (AVS). Different genres and generations of transcatheter heart valves (THVs) are accessible, offering operators an opportunity to choose a patient-tailored device. In this single-center study, we present the outcomes of Serbian patients treated with next-generation Myval THV for severe symptomatic AVS. Myval THV was implanted in all consecutive patients who underwent TAVI at the Dedinje Cardiovascular Institute of Belgrade, Serbia between October 2020 and September 2021. The primary endpoint was device success on day 30. Secondary endpoints included 30-day all-cause mortality, cardiovascular death, stroke, moderate/severe paravalvular leak (PVL), and new permanent pacemaker implantation (PPI). TAVI was performed as per the European Society of Cardiology guidelines. The study comprised thirteen patients, aged 72±13 years with mean EuroSCORE (7.17%) and Society of Thoracic Surgeons (2.72%,) scores who underwent TAVI successfully with 92.3% using the percutaneous approach. Myval THV intermediate and extra-large sizes were implanted in 46% and 15% of patients, respectively. This acute procedure success rate was 100%. The primary composite endpoint of early device success was achieved in all patients. None of the patients had clinically significant aortic regurgitation or moderate/severe PVL. No patient experienced stroke, contrast-induced acute kidney injury, device-related vascular complications, or a new PPI. The all-cause mortality rate at 30 days was 0%. Myval THV system demonstrated a favorable safety/efficacy profile within 30 days post-procedure at a single center in Serbia. This is the first report of my experience with Myval THV from Serbia
    corecore