6 research outputs found

    Development of Real-Time PCR Assays for the Quantitative Detection of Epstein-Barr Virus and Cytomegalovirus, Comparison of TaqMan Probes, and Molecular Beacons

    No full text
    Human Epstein-Barr virus (EBV) and cytomegalovirus (CMV) can cause serious complications in immunocompromised patients. Rapid diagnosis of EBV and CMV infection is critical in the management of the disease so that anti-viral therapy can be started early. Here we describe the development of real-time PCR assays using TaqMan probes and molecular beacons and compare the performance of both assays with a well-established, validated, gel-based PCR method for the quantification of EBV and CMV in patients’ samples. The TaqMan and molecular beacon assays were linear between 10 to 107 viral genomes/reaction. Both assays generated calibration curves with strong correlation and low intra-assay and interassay variation. Results of EBV and CMV viral load determination inpatient samples obtained by the gel-based and real-time PCR were very similar. The real-time PCR assays showed increases in viral load before clinical measures of viral disease and decreases in viral load during anti-viral therapy in two of six pediatric patients. The data indicate that these TaqMan and molecular beacon approaches are accurate, rapid, and reliable assays for the diagnosis and monitoring of EBV and CMV infections in patients

    Copyright © American Society for Investigative Pathology and the Association for Molecular Pathology Development of Real-Time PCR Assays for the Quantitative Detection of Epstein-Barr Virus and Cytomegalovirus, Comparison of TaqMan Probes, and Molecular B

    No full text
    Human Epstein-Barr virus (EBV) and cytomegalovirus (CMV) can cause serious complications in immunocompromised patients. Rapid diagnosis of EBV and CMV infection is critical in the management of the disease so that anti-viral therapy can be started early. Here we describe the development of real-time PCR assays using TaqMan probes and molecular beacons and compare the performance of both assays with a well-established, validated, gel-based PCR method for the quantification of EBV and CMV in patients ’ samples. The TaqMan and molecular beacon assays were linear between 10 to 10 7 viral genomes/reaction. Both assays generated calibration curves with strong correlation and low intra-assay and interassay variation. Results of EBV and CMV viral load determination inpatien

    Comparison of Automated Nucleic Acid Extraction Methods with Manual Extraction

    No full text
    Automated nucleic acid extractors can improve workflow and decrease variability in the clinical laboratory. We evaluated Qiagen EZ1 (Valencia, CA) and bioMérieux (Durham, NC) easyMAG extractors compared with Qiagen manual extraction using targets and matrices commonly available in the clinical laboratory. Pooled samples were spiked with various organisms, serially diluted, and extracted in duplicate. The organisms/matrices were Bordetella pertussis/bronchoalveolar lavage, herpes simplex virus II/cerebrospinal fluid, coxsackievirus A9/cerebrospinal fluid, BK virus/plasma, and Mycoplasma pneumoniae/endotracheal tube samples. Extracts were amplified in duplicate using real-time PCR assays, and amplification of the target at a cycle threshold of 35 using the manual method was used for comparison. Amplification efficiency of nucleic acids extracted by automated methods was similar to that by the manual method except for a loss of efficiency for M. pneumoniae in endotracheal tube samples. The EZ1 viral kit 2.0 gave better results for coxsackievirus A9 than the EZ1 viral kit version 1.0. At the lowest limit of detection (past a cycle threshold of 35), the easyMAG was more likely to produce amplifiable nucleic acid than were either the EZ1 or manual extraction. Operational complexity, defined as the number of manipulations required to obtain an extracted sample, was the lowest for the easyMAG. The easyMAG was the most expensive of the methods, followed by the EZ1 kit and manual extraction

    Effect of transcatheter aortic valve implantation vs surgical aortic valve replacement on all-cause mortality in patients with aortic stenosis

    No full text
    Importance: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement and is the treatment of choice for patients at high operative risk. The role of TAVI in patients at lower risk is unclear. Objective: To determine whether TAVI is noninferior to surgery in patients at moderately increased operative risk. Design, Setting, and Participants: In this randomized clinical trial conducted at 34 UK centers, 913 patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk due to age or comorbidity were enrolled between April 2014 and April 2018 and followed up through April 2019. Interventions: TAVI using any valve with a CE mark (indicating conformity of the valve with all legal and safety requirements for sale throughout the European Economic Area) and any access route (n = 458) or surgical aortic valve replacement (surgery; n = 455). Main Outcomes and Measures: The primary outcome was all-cause mortality at 1 year. The primary hypothesis was that TAVI was noninferior to surgery, with a noninferiority margin of 5% for the upper limit of the 1-sided 97.5% CI for the absolute between-group difference in mortality. There were 36 secondary outcomes (30 reported herein), including duration of hospital stay, major bleeding events, vascular complications, conduction disturbance requiring pacemaker implantation, and aortic regurgitation. Results: Among 913 patients randomized (median age, 81 years [IQR, 78 to 84 years]; 424 [46%] were female; median Society of Thoracic Surgeons mortality risk score, 2.6% [IQR, 2.0% to 3.4%]), 912 (99.9%) completed follow-up and were included in the noninferiority analysis. At 1 year, there were 21 deaths (4.6%) in the TAVI group and 30 deaths (6.6%) in the surgery group, with an adjusted absolute risk difference of −2.0% (1-sided 97.5% CI, −∞ to 1.2%; P < .001 for noninferiority). Of 30 prespecified secondary outcomes reported herein, 24 showed no significant difference at 1 year. TAVI was associated with significantly shorter postprocedural hospitalization (median of 3 days [IQR, 2 to 5 days] vs 8 days [IQR, 6 to 13 days] in the surgery group). At 1 year, there were significantly fewer major bleeding events after TAVI compared with surgery (7.2% vs 20.2%, respectively; adjusted hazard ratio [HR], 0.33 [95% CI, 0.24 to 0.45]) but significantly more vascular complications (10.3% vs 2.4%; adjusted HR, 4.42 [95% CI, 2.54 to 7.71]), conduction disturbances requiring pacemaker implantation (14.2% vs 7.3%; adjusted HR, 2.05 [95% CI, 1.43 to 2.94]), and mild (38.3% vs 11.7%) or moderate (2.3% vs 0.6%) aortic regurgitation (adjusted odds ratio for mild, moderate, or severe [no instance of severe reported] aortic regurgitation combined vs none, 4.89 [95% CI, 3.08 to 7.75]). Conclusions and Relevance: Among patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk, TAVI was noninferior to surgery with respect to all-cause mortality at 1 year. Trial Registration: isrctn.com Identifier: ISRCTN57819173

    List of publications on the economic and social histoy of Great Britain and Ireland

    No full text
    corecore