40 research outputs found

    Hyperglycaemia in the Newborn Infant. Physiology Verses Pathology.

    Get PDF
    Hyperglycemia is common in newborns requiring intensive care, particularly in preterm infants, in sepsis and following perinatal hypoxia. The clinical significance, and optimal intervention strategy varies with context, but hyperglycaemia is associated with increased mortality and morbidity. The limited evidence for optimal clinical targets mean controversy remains regarding thresholds for intervention, and management strategies. The first consideration in the management of hyperglycaemia must be to ascertain potentially treatable causes. Calculation of the glucose infusion rate (GIR) to insure this is not excessive, is critical but the use of insulin is often helpful in the extremely preterm infant, but is associated with an increased risk of hypoglycaemia. The use of continuous glucose monitoring (CGM) has recently been demonstrated to be helpful in targeting glucose control, and reducing the risk from hypoglycaemia in the preterm infant. Its use in other at risk infants remains to be explored, and further studies are needed to provide a better understanding of the optimal glucose targets for different clinical conditions. In the future the combination of CGM and advances in computer algorithms, to provide intelligent closed loop systems, could allow a safer and more personalized approached to management

    A feasibility study of paired Continuous Glucose Monitoring (CGM) intra-partum and in the newborn in pregnancies complicated by Type 1 Diabetes

    Get PDF
    Aim: To describe the continuous glucose monitoring (CGM) profiles of type 1 diabetes (T1D) offspring in the early neonatal period and its association with maternal intrapartum glucose control. Methods: A prospective observational study of T1D pregnant women and their neonatal offspring. Women had a CGM sensor inserted 2-3 days prior to delivery. Infants had a masked CGM sensor inserted as soon as possible following delivery. Maternal glycaemic outcomes were time-in-target (70-140 mg/dL [3.9-7.8 mmol/L]), hyperglycaemia >140 mg/dL (7.8 mmol/L) and mean CGM glucose during the 24 hours preceding delivery. Neonatal outcomes included lowest recorded blood glucose concentration, and CGM measures (glucose 140 mg/dL (7.8 mmol/L), and 9 (9) % time < 70 mg/dL (3.9 mmol/L) with mean (SD) CGM glucose 113 (9) mg/dL (6.3 [0.7] mmol/L). 15 infants (93.8%) had ≥1 blood glucose concentration < 47 mg/dL (2.6 mmol/L) and five had ≥1 blood glucose concentration < 18 mg/dL (1.0 mmol/L). The mean infant CGM glucose on days 1, 2, and 3 of life was 63 (14), 67 (13), 76 (11) mg/dL (3.5 [0.8], 3.7 [0.7], and 4.2 [0.6] mmol/L). Four infants (25%) spent more than 50% time with CGM glucose levels < 47 mg/dL (2.6 mmol/L) on day 1. Conclusions: CGM detected widespread neonatal hypoglycaemia, even among mothers with good intrapartum glucose control

    Maternal glycaemic control and risk of neonatal hypoglycaemia in Type 1 diabetes pregnancy: a secondary analysis of the CONCEPTT trial

    Get PDF
    Aims: To examine the relationship between maternal glycaemic control and risk of neonatal hypoglycaemia using conventional and continuous glucose monitoring (CGM) metrics in the Continuous Glucose Monitoring in Type 1 Diabetes Pregnancy Trial (CONCEPTT) participants. Methods: A secondary analysis of CONCEPTT involving 225 pregnant women and their liveborn infants. Antenatal glycaemia was assessed at 12, 24 and 34 weeks gestation. Intrapartum glycaemia was assessed by CGM measures 24 hours prior to delivery. The primary outcome was neonatal hypoglycaemia defined as glucose concentration 97.7th centile (63.2% vs 33.9%; p<0.0001) and skinfold thickness (p≤0.02). Intrapartum CGM was available for 33 participants, with no differences between mothers of neonates with and without hypoglycaemia. Conclusions: Modest increments in CGM time-in-target (5-7% increase) during the second and third trimesters are associated with reduced risk for neonatal hypoglycaemia. While more intrapartum CGM data are needed, the higher birthweight and skinfold measures associated with neonatal hypoglycaemia, suggest that risk is related to fetal hyperinsulinemia preceding the immediate intrapartum period

    Drug delivery from a solid formulation during breastfeeding-A feasibility study with mothers and infants.

    Get PDF
    Funder: University of Cambridge WD Armstrong TrustFunder: University of Cambridge Kurt Hahn TrustFunder: Studienstiftung des Deutschen Volkes; funder-id: http://dx.doi.org/10.13039/501100004350BACKGROUND: Breastfeeding is critical to health outcomes, particularly in low-resource settings where there is little access to clean water. For infants in their first twelve months of life, the delivery of medications is challenging, and use of oral syringes to deliver liquid formulations can pose both practical and emotional challenges. OBJECTIVE: To explore the potential to deliver medicine to infants via a solid formulation during breastfeeding. METHODS: Single center feasibility study within a tertiary level neonatal unit in the UK, involving twenty-six breastfeeding mother-infant dyads. A solid formulation of Vitamin B12 was delivered to infants during breastfeeding. Outcomes included the quantitative change in serum vitamin B12 and assessment of maternal expectations and experiences. RESULTS: Delivery of Vitamin B12 through a solid formulation that dissolved in human milk did not impair breastfeeding, and Vitamin B12 levels rose in all infants from a mean baseline (range) 533 pg/mL (236-925 pg/mL) to 1871 pg/mL (610-4981 pg/mL) at 6-8 hours post-delivery. Mothers described the surprising ease of 'drug' delivery, with 85% reporting a preference over the use of syringes. CONCLUSIONS: Solid drug formulations can be delivered during breastfeeding and were preferred by mothers over the delivery of liquid formulations via a syringe

    Protocol of a randomised controlled trial of real-time continuous glucose monitoring in neonatal intensive care 'REACT'.

    Get PDF
    INTRODUCTION: Hyperglycaemia is common in the very preterm infant and has been associated with adverse outcomes. Preventing hyperglycaemia without increasing the risk of hypoglycaemia has proved challenging. The development of real-time continuous glucose monitors (CGM) to inform treatment decisions provides an opportunity to reduce this risk. This study aims to assess the feasibility of CGM combined with a specifically designed paper guideline to target glucose control in the preterm infant. METHODS AND ANALYSES: The Real Time Continuous Glucose Monitoring in Neonatal Intensive Care (REACT) trial is an international multicentre randomised controlled trial. 200 preterm infants ≤1200 g and ≤24 hours of age will be randomly allocated to either real-time CGM or standard care (with blinded CGM data collection). The primary outcome is time in target 2.6-10 mmol/L during the study intervention assessed using CGM. Secondary outcomes include efficacy relating to glucose control, utility including staff acceptability, safety outcomes relating to incidence and prevalence of hypoglycaemia and health economic analyses. ETHICS AND DISSEMINATION: The REACT trial has been approved by the National Health Service Health Research Authority National Research Ethics Service Committee East of England (Cambridge Central); Medical Ethics Review Committee, VU University Medical Centre, Amsterdam, The Netherlands and the Research Ethics Committee, Sant Joan de Déu Research Foundation, Barcelona, Spain. Recruitment began in July 2016 and will continue until mid-2018. The trial has been adopted by the National Institute of Health Research Clinical Research Network portfolio (ID: 18826) and is registered with anInternational Standard Randomised Control Number (ISRCTN registry ID: 12793535). Dissemination plans include presentations at scientific conferences, scientific publications and efforts at stakeholder engagement. TRIAL REGISTRATION NUMBER: ISRCTN12793535; Pre-results
    corecore