43 research outputs found

    Double arterial perfusion strategy for extensive thoracic aortic surgery to avoid lower body hypothermic circulatory arrest

    Get PDF
    OBJECTIVE To analyse our results of using a double arterial perfusion strategy to avoid lower body hypothermic circulatory arrest after extensive thoracic aortic surgery. METHODS We analysed the intra- and perioperative courses of 10 patients (median age 58 years, median logistic EuroSCORE 14.6) who underwent extensive thoracic aortic surgery with a double arterial perfusion strategy. The main goal of double arterial perfusion is to separate myocardial and supra-aortic from systemic perfusion. Aortic repair starts at the most distal level of the descending aorta, followed by reinsertion of the supra-aortic vessels, and ends with completion of the proximal anastomosis or by any kind of root repair as needed. RESULTS Seven of 10 patients had prior surgery of the thoracic aorta. Indications for surgery were post-dissection aneurysm in 4 patients, true aneurysm in 3, anastomotic aneurysms in 2 and Type B aortic dissection with pseudo-coarctation in 1. Surgical access was performed through median sternotomy with left hemi-clamshell extension in all cases. There was no in-hospital mortality, but perioperative neurological symptoms occurred in 2 patients. These 2 patients developed delayed stroke (after awaking) after an initial uneventful clinical course, and in 1 of them, neurological symptoms resolved completely during follow-up. The median follow-up was 7 (±13) months. There was no death and no need for additional redo surgery during this observational period. CONCLUSIONS Extensive surgery of the thoracic aorta using a double arterial perfusion technique in order to avoid lower body hypothermic circulatory arrest is an attractive option. Further refinements of this technique may enable the safe and effective simultaneous multisegmental treatment of thoracic aortic pathology in patients who would otherwise have to undergo a two-step surgical approac

    Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation†

    Get PDF
    OBJECTIVES Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique. METHODS Transcranial Doppler (TCD) ultrasound recordings of 44 patients undergoing TAVI (age 78±6 years; logistic EuroSCORE 28±15%; transfemoral access, n=32; transapical access, n=12; SE, n=27; BE, n=17) were analysed for HITS during the following intervals: (i) instrumentation prior to valvuloplasty, (ii) balloon valvuloplasty, (iii) prosthesis deployment (DP) and (iv) post-implantation (PI) including any re-dilatation episodes. The total procedural load of HITS and HITS frequency in procedural intervals were compared between different access routes and DP techniques. Periprocedural neurocognitive impairment was assessed clinically and by the confusion assessment method (CAM) prior to TAVI and on post-procedural days 1 and 4-6. RESULTS TCD recordings demonstrated the occurrence of HITS in all patients. DP was associated with the highest load of HITS. Access route did not significantly influence the total burden of periprocedural HITS. During procedures using the SE type, a slightly larger total load of HITS was observed than with the BE type (P=0.024). This was mainly due to more HITS during the DP (P=0.027) and the PI interval (P=0.002). No incidence of delirium was detected by CAM ratings. Two patients suffered a new onset of stroke within the 2 weeks following the procedure. In-hospital death and 30-day mortality were 0/44. CONCLUSIONS HITS are observed during all procedural intervals in TAVI. The embolic events appear to peak during DP. In our series, the overall cerebral embolic load did not differ between the transfemoral and the transapical access route. TCD monitoring in TAVI is useful to identify periods and manipulations associated with an increased cerebral embolic load and may help to further enhance the safety of this procedur

    Massive pulmonary embolism: surgical embolectomy versus thrombolytic therapy—should surgical indications be revisited?†

    Get PDF
    OBJECTIVES The treatment of massive pulmonary embolism (PE) is a matter of debate. We present our institutional experience of patients suffering from massive PE with the aim of comparing the early results, the outcome and quality of life (QoL) between patients primarily assigned to either pulmonary surgical embolectomy (SE) or thrombolytic therapy (TL). A subgroup of patients (TS) with failed responses to TL requiring SE was separately analysed. METHODS All consecutive patients (January 2001-December 2007) with computed tomography (CT)-scan-confirmed massive bilateral central or paracentral PE were reviewed. All clinical data were retrieved from our patients' registry and completed by the evaluation of the CT-scan-derived right ventricle/left ventricle ratio (RV/LV ratio). Follow-up focused on clinical outcome and QoL was obtained. RESULTS Eighty patients were analysed including 28 SE (35%) and 52 TL (65%), of whom 11 (21%) required TS. Demographics and preoperative characteristics were similar between SE and TL. Analysis of the RV/LV ratio revealed a ratio of 1.66 for SEand 1.44 for TL. The early mortality rate was not significantly different between the two groups (SE: 3.6% versus TL: 13.5%), whereas early mortality was 27% in those patients treated initially with thrombolysis and subsequently requiring SE (TS-group). Severe bleeding complications were lower in the SE-group (3.6% versus 26.5% P=0.013). Intracerebral bleeding rates and neurological events were not statistically different. After a mean follow-up of 63±21 months, the mortality rate was 17.9% in the SE-group and 23.1% in the TL-group. CONCLUSIONS SE is an excellent treatment option in massive PE with comparable early mortality rates and significantly less bleeding complications than TL. Patients having surgery after inefficient thrombolysis have the worst early outcome. The RV/LV CT-scan ratio might serve as a predictor to differentiate patients, who could profit from direct surgical intervention than thrombolytic treatment attempts. Further studies are required to confirm these result

    Double arterial perfusion strategy for extensive thoracic aortic surgery to avoid lower body hypothermic circulatory arrest

    Get PDF
    OBJECTIVE To analyse our results of using a double arterial perfusion strategy to avoid lower body hypothermic circulatory arrest after extensive thoracic aortic surgery. METHODS We analysed the intra- and perioperative courses of 10 patients (median age 58 years, median logistic EuroSCORE 14.6) who underwent extensive thoracic aortic surgery with a double arterial perfusion strategy. The main goal of double arterial perfusion is to separate myocardial and supra-aortic from systemic perfusion. Aortic repair starts at the most distal level of the descending aorta, followed by reinsertion of the supra-aortic vessels, and ends with completion of the proximal anastomosis or by any kind of root repair as needed. RESULTS Seven of 10 patients had prior surgery of the thoracic aorta. Indications for surgery were post-dissection aneurysm in 4 patients, true aneurysm in 3, anastomotic aneurysms in 2 and Type B aortic dissection with pseudo-coarctation in 1. Surgical access was performed through median sternotomy with left hemi-clamshell extension in all cases. There was no in-hospital mortality, but perioperative neurological symptoms occurred in 2 patients. These 2 patients developed delayed stroke (after awaking) after an initial uneventful clinical course, and in 1 of them, neurological symptoms resolved completely during follow-up. The median follow-up was 7 (±13) months. There was no death and no need for additional redo surgery during this observational period. CONCLUSIONS Extensive surgery of the thoracic aorta using a double arterial perfusion technique in order to avoid lower body hypothermic circulatory arrest is an attractive option. Further refinements of this technique may enable the safe and effective simultaneous multisegmental treatment of thoracic aortic pathology in patients who would otherwise have to undergo a two-step surgical approach

    Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation

    Get PDF
    Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique
    corecore