65 research outputs found

    Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    Get PDF
    Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation: We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Conclusions: Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery

    Feasibility and initial experience of assessment of mechanical dyssynchrony using cardiovascular magnetic resonance and semi-automatic border detection

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The systolic dyssynchrony index (SDI) has been introduced as a measure of mechanical dyssynchrony using three-dimensional echocardiography to select patients who may benefit from cardiac resynchronization therapy (CRT). However, three-dimensional echocardiography may be inadequate in a number of patients with suboptimal acoustic window and no single echocardiographic measure of dyssynchrony has proven to be of value in selecting patients for CRT. Thus, the aim of this study was to determine the value of cardiovascular magnetic resonance (CMR) for the assessment of the SDI in patients with reduced LV function as well as in healthy controls using semi-automatic border tracking.</p> <p>Methods</p> <p>We investigated a total of 45 patients including 35 patients (65 ± 8 years) with reduced LV function (EF 30 ± 11%) and a wide QRS complex as well as 10 control subjects (42 ± 21 years, EF 70 ± 11%). For cine imaging a standard SSFP imaging sequence was used with a temporal resolution of 40 frames per RR-interval. Quantitative analysis was performed off-line using a software prototype for semi-automatic border detection. Global volumes, ejection fraction and the SDI were calculated in each subject. SDI was compared with standard echocardiographic parameters of dyssynchrony.</p> <p>Results</p> <p>The mean SDI differed significantly between patients (14 ± 5%) and controls (5 ± 2%, p < 0.001). An exponential correlation between the EF and the SDI was observed (r = -0.84; p < 0.001). In addition, a significant association between the SDI and the standard deviation of time to peak systolic motion of 12 LV segments (Ts-SD) determined by echocardiography was observed (r = 0.66, p = 0.002).</p> <p>Conclusion</p> <p>The results of this preliminary study suggest that CMR with semi-automatic border detection may be useful for the assessment of mechanical dyssynchrony in patients with reduced LV function.</p> <p>No trial registration due to recruitment period between October 2004 and November 2006</p

    First experience with a new negative pressure incision management system on surgical incisions after cardiac surgery in high risk patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sternal wound infection remains a serious potential complication after cardiac surgery. A recent development for preventing wound complications after surgery is the adjunctive treatment of closed incisions with negative pressure wound therapy. Suggested mechanisms of preventive action are improving the local blood flow, removing fluids and components in these fluids, helping keep the incision edges together, protecting the wound from external contamination and promoting incision healing. This work reports on our initial evaluation and clinical experience with the Prevena™Incision Management System, a recently introduced new negative pressure wound therapy system specifically developed for treating closed surgical incisions and helping prevent potential complications. We evaluated the new treatment on sternal surgical incisions in patients with multiple co-morbidities and consequently a high risk for wound complications.</p> <p>Methods</p> <p>The Prevena™incision management system was used in 10 patients with a mean Fowler risk score of 15.1 [Range 8-30]. The negative pressure dressing was applied immediately after surgery and left in place for 5 days with a continuous application of -125 mmHg negative pressure. Wounds and surrounding skin were inspected immediately after removal of the Prevena™ incision management system and at day 30 after surgery.</p> <p>Results</p> <p>Wounds and surrounding skin showed complete wound healing with the absence of skin lesions due to the negative pressure after removal of the Prevena™ dressing. No device-related complications were observed. No wound complications occurred in this high risk group of patients until at least 30 days after surgery.</p> <p>Conclusions</p> <p>The Prevena™system appears to be safe, easy to use and may help achieve uncomplicated wound healing in patients at risk of developing wound complications after cardiothoracic surgery.</p

    Management of near fatal blunt laryngeal trauma

    No full text
    corecore